Classification: 27171303 [AHE438003]

Preferred name 27-17-13-03 Combination arrester power engineering DC (Type 1+2)
Definition Devices for lightning equipotential bonding between the external lightning protection system and the DC part of the electrical installation, which can discharge both lightning currents and surge currents
Keywords Lightning protection External lightning protection
IRDI 0173-1#01-AHE438#003
Already on the watchlist: 0 of max. 4

BASIC Properties: Combination arrester power engineering DC (Type 1+2)

  • voltage protection level (DC+ - DC-)
  • minimum ambient temperature (during operation)
  • Valuelist suitable for outdoor use
  • min. relative humidity (operation)
  • Insulation stripped length
  • width of packing
  • max. relative humidity (operation)
  • width
  • Valuelist Degree of protection (IP), mounted
  • length of packing
  • Valuelist flammability rating of the insulating material (based on UL 94)
  • Manufacturer product family
  • max. continuous operating voltage DC
  • Manufacturer product root
  • gross weight
  • Manufacturer product order suffix
  • follow current extinguishing capability
  • Manufacturer product description
  • maximum ambient temperature (during operation)
  • product article number of manufacturer
  • height
  • Valuelist fault indication at device
  • GTIN
  • nominal voltage (at DC)
  • Manufacturer name
  • depth
  • Brand
  • Valuelist type of electrical terminal
  • Net weight
  • GLN of manufacturer
  • Product type
  • Manufacturer product designation
  • Valuelist width in units of measurement
  • min. connectable conductor cross-section multiple wire
  • Min. line cross section, rigid
  • Max. line cross section, rigid
  • max. connectable conductor cross-section multiple wire
  • address of additional link
  • Customs tariff number
  • Supplier product designation
  • GLN of supplier
  • name of supplier
  • product article number of supplier
  • Supplier product type
  • Supplier product order suffix
  • Supplier product description
  • Supplier product family
  • Supplier product root
  • max. current of remote indication (DC)
  • residual current DC
  • rated load current
  • TOV - voltage (120 min)
  • TOV - voltage (5 s)
  • Valuelist protective element pluggable
  • Valuelist TOV - behaviour (5 s)
  • min. cross-section of the remote indication (flexible)
  • max. cross-section of the remote indication (rigid)
  • Valuelist SPD failure mode
  • Valuelist possible to use on AC voltage
  • Valuelist TOV - behaviour (120 min)
  • max. cross-section of the remote indication (flexible)
  • Valuelist no leakage current
  • max. current of remote indication (AC)
  • max. voltage of remote indication (DC)
  • distance to grounded or conductive parts
  • max. voltage of remote indication (AC)
  • max. overcurrent protective device
  • short-circuit current rating in case of max. OCPD on supply lines
  • Valuelist type of DC system
  • voltage protection level (DC- - PE)
  • min. cross-section of the remote indication (rigid)
  • nominal discharge current (8/20) µs (DC- - PE)
  • voltage protection level (DC+ - PE)
  • nominal discharge current (8/20) µs (DC+ - PE)
  • Valuelist SPD type based on IEC 61643
  • Valuelist characteristic of backup fuse
  • max. discharge current (8/20) µs (DC- - PE)
  • nominal discharge current (8/20) µs (DC+ - DC-)
  • Valuelist type of remote indication contact
  • max. discharge current (8/20) µs (DC+ - DC-)
  • max. discharge current (8/20) µs (DC+ - PE)
  • impulse discharge current (10/350) µs (DC+ - PE)
  • impulse discharge current (10/350) µs (DC- - PE)
  • Valuelist number of ports
  • Valuelist tested based on the standards
  • Valuelist configuration
  • max. continuous operating voltage AC for DC-SPDs
  • total discharge current (10/350) µs
  • Valuelist remote indication integrated
  • max. allowed elevation above mean sea level
  • Valuelist connection method of the remote indication
  • depth of packing
  • Contents per packing unit
  • Valuelist Assembly type
X

We need your consent

This website uses necessary cookies to ensure the operation of the website. There is no analysis of user behavior by third parties. You can find detailed information about the use of cookies in our privacy policy.