在ECLASS标准中搜索
ECLASS 让您有机会免费查看和搜索最新的 ECLASS 版本。 搜索功能直观,让您快速了解标准,不拘泥于官僚主义。
使用 ECLASS 搜索
请首先选择 ...
- 您想搜索 ECLASS 基本或高级
- 您想搜索哪个版本
- 搜索语言
- 是否要搜索类别或特征、值等。
然后输入搜索词(如 "铅笔"),点击 "搜索"。
请注意,使用 ECLASS 标准需要许可证。(另请参阅 ECLASS 使用条款)
Classification: 36030403 [AKL251019]
Preferred name | 36-03-04-03 Silo, bunker (open) |
---|---|
IRDI | 0173-1#01-AKL251#019 |
|
BASIC Properties: Silo, bunker (open)
-
Type description
-
Valuelist Construction type
-
Reference norm of the surface properties, room1
-
Number of supports nominal group 3
-
Reference norm of the explosion protection
-
Material description of the room1
-
Volume of the room2
-
Construction form of the container bottom
-
Construction of the thermal transfer surface room3/room1
-
Material description of the room2
-
Reference norm the number of muffs
-
Volume of the room3
-
item list number of manufacturer
-
Code of the manufacturer declaration
-
Reference norm material of the room3
-
Reference norm material of the device flange
-
Reference norm material of the static seal, room1
-
Material number of the coating, room1
-
drawing number of manufacturer
-
Nominal volume
-
Material description of the carrying construction
-
Reference norm wind load
-
Material number of the design
-
Material number of the carrying construction
-
Reference norm material of the coating, room1
-
Material description of the device flange
-
Material number of the room2
-
Material number of the room3
-
Material number of the design room3
-
Valuelist material code of coating (external surface)
-
Reference norm material, design, room 3
-
Volume of the room1
-
Valuelist guideline for conformity declaration
-
Material number of the room1
-
Construction of the static seal, room1
-
Material number of the static seal, room1
-
code of conformity evaluation
-
Max. permissible operating weight
-
Manufacturer order code
-
material of coating (external surface)
-
Reference norm of the static seal, room1
-
fabrication number
-
Material description of the room3
-
Material description of the design room3
-
Number of supports nominal group 2
-
classification system
-
Reference norm of the earthquake zone
-
Material description of the coating, room1
-
Material description of the design room2
-
reference standard for the coating (external surface)
-
Reference norm material, design, room 2
-
Construction of the seal surface, device flange
-
Material number of the design room2
-
Material description of the static seal, room1
-
Material description of the design
-
Reference norm of the coating, room1
-
Number of device flanges
-
Reference norm material, design
-
Number of supports nominal group 1
-
Wind load zone
-
Product country of origin
-
Reference norm material of the carrying construction
-
Reference norm material of the room2
-
Reference norm of the device flange
-
empty weight
-
GLN of supplier
-
Supplier product type
-
Supplier product order suffix
-
Supplier product root
-
Supplier product family
-
Max. permissible overpressure PS1+ at TS1, room1
-
HS-Code of the WCO
-
Valuelist Use of customs tariff number
-
Valuelist Type of customs tariff number
-
Customs tariff number
-
Max. permissible overpressure PS2+ at TS2, room2
-
Max. permissible overpressure PS2+ at TS2, room1
-
Thickness of the dampening
-
Max. permissible underpressure PS1- at TS1, room2
-
Wall thickness of the container case
-
Max. permissible underpressure PS1- at TS1, room1
-
Max. permissible underpressure PS2- at TS2, room2
-
Max. permissible underpressure PS2- at TS2, room1
-
code of class
-
reference standard
-
Material number of the device flange
-
reference standard for material of the coating (external surface)
-
Earthquake zone
-
Reference norm material of the room1
-
Nominal width of the device flange
-
Number of the discharge aids
-
address of additional link
-
Brand
-
Manufacturer product description
-
product article number of manufacturer
-
Manufacturer name
-
GTIN
-
URI of manufacturer
-
GLN of manufacturer
-
URI of the product
-
Product type
-
Manufacturer product designation
-
Manufacturer product family
-
Manufacturer product root
-
Manufacturer product order suffix
-
Supplier product description
-
name of supplier
-
product article number of supplier
-
Supplier product designation
-
Max. permissible operating temperature at TS1, room1
-
Construction type of the discharge aid
-
country of manufacturer
-
Layout of the installation venue
-
Surface properties of the room1
-
Type of coating application, room 1
-
Type of coating application, external surface
-
Valuelist construction size
-
Min. permissible operating temperature at TS2, room3
-
Min. permissible operating temperature at TS2, room2
-
Max. permissible operating temperature at TS1, room2
-
Max. permissible overpressure PS2+ at TS2, room3
-
Max. permissible overpressure PS1+ at TS1, room3
-
Max. permissible overpressure PS1+ at TS1, room2
-
Valuelist explosion protection marking
-
Number of rooms
-
Reference norm of the dampening
-
supplier of the identifier
-
Construction of the thermal transfer surface room2/room1
-
Construction form of the dampening
-
Construction form of the holder, dampening
-
Construction form of the carrying construction
-
Nominal diameter of the room1
-
overall width
-
design
-
Max. permissible underpressure PS2- at TS2, room3
-
Max. permissible underpressure PS1- at TS1, room3
-
Thickness of the coating, room1
-
description of class
-
overall length
-
Min. permissible operating temperature at TS2, room1
-
Opening tilt of the funnel
-
Max. permissible operating temperature at TS1, room3
-
Thermal transfer surface room1/room3
-
Thermal transfer surface room1/room2
-
Valuelist Dampening holder present
-
Valuelist Wind load to be applied
-
Valuelist conformity declaration present
-
Valuelist Manufacturer declaration present
-
Valuelist Explosion protection certificate present
-
Valuelist Earthquake load to be applied
-
over all height
-
thickness of coating (external surface)