在ECLASS标准中搜索

ECLASS 让您有机会免费查看和搜索最新的 ECLASS 版本。 搜索功能直观,让您快速了解标准,不拘泥于官僚主义。

使用 ECLASS 搜索

请首先选择 ...

  • 您想搜索 ECLASS 基本或高级
  • 您想搜索哪个版本
  • 搜索语言
  • 是否要搜索类别或特征、值等。

然后输入搜索词(如 "铅笔"),点击 "搜索"。
 

请注意,使用 ECLASS 标准需要许可证。(另请参阅 ECLASS 使用条款

eclass image

Classification: 27171402 [AHE443003]

Preferred name 27-17-14-02 Surge arrester power engineering PV (type 2)
Definition Devices for discharging surge currents that are coupled either directly (galvanically) or indirectly (inductively) into the power engineering part of photovoltaic systems designed in direct voltage
Keywords Lightning protection External lightning protection
IRDI 0173-1#01-AHE443#003
Already on the watchlist: 0 of max. 4

BASIC Properties: Surge arrester power engineering PV (type 2)

  • Contents per packing unit
  • Valuelist Approval certificates
  • depth of packing
  • Valuelist connection method of the remote indication
  • max. allowed elevation above mean sea level
  • max. continuous operating voltage DC-PV
  • Valuelist remote indication integrated
  • Valuelist configuration
  • Valuelist SPD type (IEC 50539)
  • max. discharge current (8/20) µs (DC+ - PE)
  • max. discharge current (8/20) µs (DC+ - DC-)
  • Valuelist type of remote indication contact
  • nominal discharge current (8/20) µs (DC+ - DC-)
  • max. discharge current (8/20) µs (DC- - PE)
  • nominal discharge current (8/20) µs (DC+ - PE)
  • voltage protection level (DC+ - PE)
  • Valuelist fault indication at device
  • product article number of manufacturer
  • height
  • Manufacturer product description
  • maximum ambient temperature (during operation)
  • Manufacturer product order suffix
  • gross weight
  • Manufacturer product root
  • Valuelist flammability rating of the insulating material (based on UL 94)
  • Manufacturer product family
  • length of packing
  • Valuelist Degree of protection (IP), mounted
  • width
  • max. relative humidity (operation)
  • width of packing
  • Insulation stripped length
  • min. relative humidity (operation)
  • Valuelist suitable for outdoor use
  • minimum ambient temperature (during operation)
  • voltage protection level (DC+ - DC-)
  • Valuelist Assembly type
  • Manufacturer product designation
  • Product type
  • GLN of manufacturer
  • Net weight
  • Brand
  • Valuelist type of electrical terminal
  • Manufacturer name
  • depth
  • GTIN
  • Valuelist UL Approbation available
  • Customs tariff number
  • address of additional link
  • Min. line cross section, rigid
  • max. connectable conductor cross-section multiple wire
  • Max. line cross section, rigid
  • min. connectable conductor cross-section multiple wire
  • Valuelist width in units of measurement
  • measured limiting voltage (DC+ - G) (UL 1449)
  • min. humidity during operation (UL 1449)
  • voltage protection rating (DC+ - DC-) (UL 1449)
  • max. humidity during operation (UL 1449)
  • Valuelist type of load, alarm circuit (UL1449)
  • min. temperature during operation, °F (UL 1449)
  • max. temperature during operation, °F (UL 1449)
  • Valuelist UL Category Code number (UL 1449)
  • operating voltage, alarm circuit AC (UL 1449)
  • max. temperature during operation, °C (UL 1449)
  • measured limiting voltage (DC+ - DC-) (UL 1449)
  • leakage current (UL 1449)
  • Valuelist number of ports (UL 1449)
  • Valuelist degree of protection (IP) (UL1449)
  • nominal discharge current (UL 1449)
  • Valuelist mode of protection PV (UL 1449)
  • min. temperature during operation, °C (UL 1449)
  • Valuelist edition of UL 1449 used for testing
  • surge current capacity per phase (UL 1449)
  • voltage protection rating (DC- - G) (UL 1449)
  • max. allowed elevation above mean sea level, m (UL 1449)
  • voltage protection rating (DC+ - G) (UL 1449)
  • Valuelist mounting method (UL 1449)
  • max. allowed elevation above mean sea level, ft (UL 1449)
  • Valuelist internal disconnect feature (UL 1449)
  • max. torque, alarm circuit (UL 1449)
  • Valuelist max. wire cross-section (UL 1449)
  • AC frequency, alarm circuit (UL 1449)
  • nominal load current, alarm circuit AC (UL1449)
  • Valuelist max. wire cross-section, alarm circuit (UL 1449)
  • nominal load current, alarm circuit DC (UL 1449)
  • operating voltage, alarm circuit DC (UL 1449)
  • Valuelist min. wire cross-section (UL 1449)
  • short-circuit current rating acc. to UL 1449
  • Valuelist min. wire cross-section, alarm circuit (UL 1449)
  • measured limiting voltage (DC- - G) (UL 1449)
  • max. permitted DC voltage (UL 1449)
  • Valuelist SPD Type (UL 1449)
  • operating voltage PV (UL 1449)
  • Valuelist type of listing (UL 1449)
  • Supplier product root
  • Supplier product family
  • Supplier product description
  • Supplier product order suffix
  • Supplier product type
  • product article number of supplier
  • name of supplier
  • GLN of supplier
  • Supplier product designation
  • min. torque (UL 1449)
  • max. torque (UL 1449)
  • min. torque, alarm circuit (UL 1449)
  • Valuelist test standard
  • Valuelist type of PV system
  • max. current of remote indication (DC)
  • nominal discharge current (8/20) µs (DC- - PE)
  • min. cross-section of the remote indication (rigid)
  • voltage protection level (DC- - PE)
  • short-circuit current rating PV
  • max. voltage of remote indication (AC)
  • distance to grounded or conductive parts
  • max. voltage of remote indication (DC)
  • max. current of remote indication (AC)
  • Valuelist no leakage current
  • max. cross-section of the remote indication (flexible)
  • Valuelist SPD failure mode
  • max. cross-section of the remote indication (rigid)
  • min. cross-section of the remote indication (flexible)
  • Valuelist protective element pluggable
  • rated load current
  • residual current DC
X

We need your consent

This website uses necessary cookies to ensure the operation of the website. There is no analysis of user behavior by third parties. You can find detailed information about the use of cookies in our privacy policy.