Classification: 27131001 [AGG201006]

Preferred name 27-13-10-01 Overcurrent-, feeder- and arc protection
Definition Protective function, for current which exceed the rated value, for feeders with different neutral point type and for arc fault in busbars and encapsulated switchgear systems
IRDI 0173-1#01-AGG201#006
Already on the watchlist: 0 of max. 4

BASIC Properties: Overcurrent-, feeder- and arc protection

  • Valuelist Electrical interface (DNP 3 serial, RS 485 with sub-D connection) present
  • Valuelist Electrical interface (DNP 3 serial, RS 485 with terminal connection) present
  • Valuelist Optical interface (PROFINET IO, 100 Mbit/s, double LC port) present
  • Valuelist Electrical interface (PROFINET IO, 100 Mbit/s, double RJ45 connector) present
  • Valuelist Software interface (DIGSI with RS 232) present
  • Valuelist Protocol is supported (IEC 61850-9-2)
  • Valuelist Optical interface (IEC 61850, 100 Mbit/s, 1300 nm double LC port) present
  • Valuelist Electrical interface (IEC 61850, 100 Mbit/s, double RJ45 connector) present
  • Valuelist Protocol is supported (HSR)
  • Valuelist Protocol is supported (PRP)
  • Valuelist Protocol is supported (RSTP)
  • Valuelist Software interface (DIGSI for Ethernet with RJ45 connector) present
  • Valuelist Type of time synchronization of transmitter, minutes-pulse present
  • Valuelist Protocol is supported (SNTP)
  • Valuelist time synchronization present
  • Valuelist Protocol is supported (DHCP)
  • Valuelist Pluggable terminal blocks present
  • Valuelist Keyswitch present
  • Valuelist IO modules expandable
  • Valuelist Changeover of setting group present
  • Valuelist Electrical interface (IEC 60870-5-103, RS 485 with terminal connection) present
  • Valuelist Operator software for protections function, DIGSI present
  • Valuelist Service interface (DIGSI at USB-A port) present
  • Valuelist Service interface present
  • Valuelist Electrical interface (PROFIBUS DP slave) present
  • Valuelist Electrical interface (IEC 60870-5-104) present
  • Valuelist Optical interface (IEC 60870-5-103, 820 nm with ST(BFOC)) present
  • Valuelist Electrical interface (IEC 60870-5-103, RS 485 with sub-D connection) present
  • Valuelist Electrical interface (Modbus RTU-slave, RS 485 with sub-D connection) present
  • Valuelist Electrical interface (Modbus RTU-slave, RS 485 with terminal connection) present
  • Valuelist Electrical interface (Modbus TCP, 100 Mbit/s, double RJ45) present
  • Valuelist Electrical interface (PROFIBUS DP slave, RS 485 with sub-D connection) present
  • Valuelist Circuit breaker monitoring present
  • Valuelist Switching statistic present
  • Valuelist Type of measured value acquisition, extended, min./max.-values, average values
  • Valuelist Type of measured value acquisition of operational measured values, standard
  • Valuelist Graphical Logic present
  • Valuelist Operating sequences for control applications present
  • Valuelist CFC arthmetic present
  • Valuelist CFC standard present
  • Valuelist External trip initiation present
  • Valuelist Inrush detection present
  • Valuelist National language user adjustable (Western European character set)
  • Valuelist Quicklogic present
  • Valuelist Monitoring present
  • Valuelist Sequence-of-events recorder present
  • Valuelist Fault recording analog and digital signals present
  • Valuelist Control present
  • Valuelist Directional time-overcurrent protection, phase, phases (ANSI 67) present
  • Valuelist Resetting interlock (ANSI 66) present
  • Valuelist Ground-fault protection (machine) (ANSI 64) present
  • Valuelist Rate-of-voltage-change protection (ANSI 59R/27R) present
  • Valuelist automatically reclosing (ANSI 79) present
  • Valuelist Trip-circuit supervision (ANSI 74TC) present
  • Valuelist Power-swing blocking (ANSI 68) present
  • Valuelist Directional time-overcurrent protection for ground-faults (ANSI 67N)
  • Valuelist Lockout (ANSI 86) present
  • Valuelist Signal transmission method (ANSI 85) present
  • Valuelist Rate-of-frequency-change protection (ANSI 81R) present
  • Valuelist Frequency protection (ANSI 81) present
  • Valuelist Load Blinder (ANSI 21LB) present
  • Valuelist Fault locator (ANSI FL) present
  • Valuelist High-impedance restricted ground-fault protection (ANSI 87N) present
  • Valuelist Differential protection (ANSI 87) present
  • Product variations
  • Frame size of enclosure
  • Wire length to the arc detector
  • Power factor
  • Required operating system for SIGRA 4-software
  • Selectable national language for DIGSI-software
  • Required operating system for DIGSI-software
  • Type of cabling of arc detector
  • Adjustable pick-up value voltage at digital input for threshold values (at DC)
  • Selectable national language for IEC 61850 system configurator software
  • Required operating system for IEC 61850 system configurator software
  • Selectable national language for SIGRA 4-software
  • Valuelist Operator software for protections function, IEC61850 system configurator present
  • Valuelist Direct. Sens. ground-fault det. for compensated and isolated network (ANSI 67Ns)
  • Valuelist Electrical interface (IEC 60870-5-103, RS 485 with RJ45 connector red.) present
  • Valuelist Licence for DIGSI 4 Professional + IEC 61850 system configurator present
  • Valuelist Licence for DIGSI 4 Professional present
  • Valuelist Licence for DIGSI 4 Basis present
  • Valuelist Operator software for protections function, SIGRA 4 present
  • Valuelist max. number of digital outputs, inclusive signaling contact
  • max. number of digital inputs
  • Number of parameter sets
  • Number of events
  • Number of low level signal-current transformer inputs
  • max. number of voltage inputs
  • max. number of current inputs
  • max. number of internal RTD-inputs
  • Number of arc detector
  • Number of sensor inputs for arc detector
  • max. number of LEDs
  • Number of low level signal-voltage transformer inputs
  • Valuelist Protocol is supported (IEC 60870-5-104)
  • Valuelist Electrical interface (IEC 60870-5-103, RS 232) present
  • Valuelist Service interface (Reydisp at USB) present
  • Valuelist Measuring-voltage failure detection (ANSI 60FL) present
  • Valuelist Supports protocol for PROFINET I0
  • Valuelist Protocol is supported (Modbus RTU-slave)
  • Valuelist Protocol is supported (Modbus TCP/IP)
  • Valuelist Protocol is supported (PROFIBUS DP slave)
  • Valuelist Electrical interface (DNP 3 TCP, 100 Mbit/s, LC port) present
  • Valuelist Electrical interface (DNP 3 TCP, 100 Mbit/s, double RJ45 connector) present
  • Valuelist Electrical interface (DNP 3 serial, RS 485 with RJ45 connector) present
  • Valuelist Protocol is supported (DNP3)
  • Valuelist IRIG-B input present
  • Valuelist Logic editor present
  • Valuelist Extended measured value acquisition present
  • Valuelist Protocol is supported (IEC 61850)
  • GTIN
  • Product type
  • Manufacturer product root
  • Manufacturer product designation
  • Manufacturer product description
  • product article number of manufacturer
  • Manufacturer name
  • Manufacturer product family
  • GLN of manufacturer
  • URI of the product
  • Brand
  • Supplier product order suffix
  • Supplier product family
  • Supplier product type
  • name of supplier
  • Supplier product description
  • Supplier product designation
  • Supplier product root
  • product article number of supplier
  • Manufacturer product order suffix
  • GLN of supplier
  • Valuelist Thermal overload protection (ANSI 49) present
  • Valuelist Overvoltage protection-Negative-sequence system (ANSI 47) present
  • Valuelist Supervision of phase rotation (ANSI 47) present
  • Valuelist Overcurrent protection-Negative-sequence system (ANSI 46) present
  • Valuelist Sensitive ground-current protection (ANSI 50Ns) present
  • Valuelist Arc-protection (ANSI AFD) present
  • Valuelist Instantaneous tripping (ANSI SOTF) present
  • Valuelist Definite time-overcurrent protection (ANSI 50/50N) present
  • Valuelist Cold loag pickup (ANSI 51C) present
  • Valuelist Inverse time-overcurrent protection (ANSI 51/51N) present
  • Valuelist Circuit-breaker failure protection (ANSI 50BF) present
  • Valuelist Intermittent ground-fault protection (ANSI 50Ns) present
  • Valuelist Overvoltage protection-Zero-sequence system (ANSI 59N) present
  • Valuelist Overvoltage protection (ANSI 59) present
  • Valuelist power factor (ANSI 55) present
  • Valuelist Voltage dependent overcurrent protection (ANSI 51V) present
  • max. supply voltage
  • min. supply voltage
  • max. supply voltage with DC
  • min. supply voltage with DC
  • width
  • Valuelist Display type
  • height
  • depth
  • Valuelist Synchronising Check (ANSI 25) present
  • Valuelist 3-pole tripping present
  • Valuelist Suitable for overcurrent protection
  • Valuelist Voltage type
  • Valuelist Unbalanced load protection (ANSI 46) present
  • Valuelist Undercurrent protection (ANSI 37) present
  • Valuelist Directional power supervision (ANSI 32) present
  • Valuelist Undervoltage protection (ANSI 27) present
  • Customs tariff number
  • HS-Code of the WCO
  • Valuelist Use of customs tariff number
  • Valuelist Type of customs tariff number
  • Max. operating temperature
  • Min. operating temperature
  • Number of function keys
  • address of additional link
  • URI of manufacturer