Classification: 27131002 [AGG202004]

Preferred name 27-13-10-02 Line differential protection
Definition Protective function, which transmits the measured value of the current from on side of the wire to the other, thereby both protection devices know their own current and the current of the remote station. The wire will be switched off through the wire, if there is a difference detected
IRDI 0173-1#01-AGG202#004
Already on the watchlist: 0 of max. 4

BASIC Properties: Line differential protection

  • Number of events
  • Valuelist Monitoring present
  • Number of parameter sets
  • Valuelist Protection communication interface, serial present
  • Valuelist circuit breaker-test present
  • Valuelist Changeover of setting group present
  • Valuelist max. number of digital outputs, inclusive signaling contact
  • max. number of digital inputs
  • Valuelist Quicklogic present
  • Valuelist Operating sequences for control applications present
  • Valuelist Inrush detection present
  • Valuelist National language user adjustable (Western European character set)
  • Valuelist Control present
  • Valuelist External trip initiation present
  • Valuelist Sequence-of-events recorder present
  • Valuelist Fault recording analog and digital signals present
  • Valuelist Service interface (DIGSI at USB-A port) present
  • Valuelist Electrical interface (IEC 60870-5-103, RS 485 with terminal connection) present
  • Valuelist Electrical interface (DNP 3 serial, RS 485 with sub-D connection) present
  • Valuelist Operator software for protections function, DIGSI present
  • Valuelist Electrical interface (Modbus RTU-slave, RS 485 with sub-D connection) present
  • Valuelist Electrical interface (DNP 3 serial, RS 485 with terminal connection) present
  • Valuelist Electrical interface (PROFIBUS DP slave) present
  • Valuelist Electrical interface (PROFIBUS DP slave, RS 485 with sub-D connection) present
  • max. number of current inputs
  • max. number of internal RTD-inputs
  • Frame size of enclosure
  • max. number of voltage inputs
  • Valuelist Service interface present
  • max. number of LEDs
  • Valuelist Electrical interface (IEC 60870-5-103, RS 485 with sub-D connection) present
  • Valuelist Electrical interface (IEC 60870-5-103, RS 232) present
  • Valuelist Arc-protection (ANSI AFD) present
  • Valuelist Instantaneous tripping (ANSI SOTF) present
  • Valuelist Inverse time-overcurrent protection (ANSI 51/51N) present
  • Valuelist Circuit-breaker failure protection (ANSI 50BF) present
  • Valuelist Overvoltage protection-Zero-sequence system (ANSI 59N) present
  • Valuelist Overvoltage protection (ANSI 59) present
  • Valuelist Directional time-overcurrent protection, phase, phases (ANSI 67) present
  • Valuelist Measuring-voltage failure detection (ANSI 60FL) present
  • Valuelist Suitable for line differential protection
  • 深度
  • Valuelist Undervoltage protection (ANSI 27) present
  • Valuelist 3-pole tripping present
  • Valuelist Overvoltage protection-Negative-sequence system (ANSI 47) present
  • Valuelist Supervision of phase rotation (ANSI 47) present
  • Valuelist Definite time-overcurrent protection (ANSI 50/50N) present
  • Valuelist Thermal overload protection (ANSI 49) present
  • Valuelist Load Blinder (ANSI 21LB) present
  • Valuelist wire break detection for Differential protection (ANSI 87N) present
  • Valuelist Type of measured value acquisition, extended, min./max.-values, average values
  • Valuelist Type of measured value acquisition of operational measured values, standard
  • Valuelist Circuit breaker monitoring present
  • Valuelist Switching statistic present
  • Valuelist CFC arthmetic present
  • Valuelist CFC standard present
  • Valuelist Trip-circuit supervision (ANSI 74TC) present
  • Valuelist Directional time-overcurrent protection for ground-faults (ANSI 67N)
  • Valuelist Frequency protection (ANSI 81) present
  • Valuelist automatically reclosing (ANSI 79) present
  • Valuelist Lockout (ANSI 86) present
  • Valuelist Rate-of-frequency-change protection (ANSI 81R) present
  • Valuelist High-impedance restricted ground-fault protection (ANSI 87N) present
  • Valuelist Differential protection (ANSI 87) present
  • Valuelist 电压类型
  • 功能键数量
  • 最大供电电压(直流) 
  • 最小供电电压(直流)
  • 最大供应电压
  • 最小供应电压
  • 高度
  • 宽度
  • Valuelist Type of customs tariff number
  • customs tariff number (TARIC)
  • HS-Code of the WCO
  • Valuelist Use of customs tariff number
  • Valuelist 显示类型
  • Customs tariff number
  • Manufacturer product designation
  • Manufacturer product order suffix
  • Product type
  • Manufacturer product root
  • 厂商产品编号
  • EAN代码
  • 商品编号
  • Supplier product root
  • GLN of supplier
  • Supplier product designation
  • URI of manufacturer
  • GLN of manufacturer
  • product identifier
  • address of additional link
  • Manufacturer product description
  • 制造商名称
  • Manufacturer product family
  • URI of the product
  • Brand
  • Supplier product family
  • Supplier product description
  • Supplier product order suffix
  • Supplier product type
  • 供货商名称
  • Valuelist Software interface (DIGSI for Ethernet with RJ45 connector) present
  • Valuelist Protocol is supported (IEC 61850-9-2)
  • Valuelist Type of time synchronization of transmitter, minutes-pulse present
  • Valuelist Software interface (DIGSI with RS 232) present
  • Valuelist Extended measured value acquisition present
  • Valuelist Service interface (Reydisp at USB) present
  • Product variations
  • Valuelist Logic editor present
  • Valuelist Protocol is supported (IEC 61850)
  • Valuelist Electrical interface (IEC 60870-5-104) present
  • Valuelist Protocol is supported (Modbus TCP/IP)
  • Valuelist Protocol is supported (DNP3)
  • Valuelist Protocol is supported (HSR)
  • Valuelist Protocol is supported (IEC 60870-5-104)
  • Valuelist Protocol is supported (RSTP)
  • Valuelist Protocol is supported (PRP)
  • Valuelist Operator software for protections function, SIGRA 4 present
  • Valuelist IRIG-B input present
  • Valuelist Licence for DIGSI 4 Professional present
  • Valuelist Licence for DIGSI 4 Professional + IEC 61850 system configurator present
  • Valuelist Pluggable terminal blocks present
  • Valuelist Licence for DIGSI 4 Basis present