Classification: 27171204 [AHE432003]

Preferred name 27-17-12-04 Combination arrester power engineering AC (type 1+2)
Definition devices for lightning equipotential bonding between the external lightning protection system and the AC power part of the electrical installation, capable of dissipating both lightning currents and surge currents
Keywords Lightning protection External lightning protection
IRDI 0173-1#01-AHE432#003
Already on the watchlist: 0 of max. 4

BASIC Properties: Combination arrester power engineering AC (type 1+2)

  • max. connectable conductor cross-section multiple wire
  • Max. line cross section, rigid
  • min. connectable conductor cross-section multiple wire
  • Valuelist width in units of measurement
  • address of additional link
  • Customs tariff number
  • GLN of manufacturer
  • Valuelist type of certificate
  • Brand
  • Net weight
  • Manufacturer name
  • Valuelist type of electrical terminal
  • Manufacturer product designation
  • Product type
  • Valuelist Degree of protection (IP), mounted
  • width
  • max. relative humidity (operation)
  • voltage protection level (N-PE)
  • Valuelist flammability rating of the insulating material (based on UL 94)
  • length of packing
  • nominal discharge current (8/20) µs (L-N)
  • Valuelist Integrated overcurrent protective device
  • Manufacturer product order suffix
  • Min. nominal frequency
  • Manufacturer product root
  • Valuelist system configuration
  • Manufacturer product family
  • follow current extinguishing capability
  • gross weight
  • GTIN
  • depth
  • Valuelist fault indication at device
  • product article number of manufacturer
  • height
  • Manufacturer product description
  • maximum ambient temperature (during operation)
  • Valuelist Approval certificates
  • depth of packing
  • Valuelist connection method of the remote indication
  • max. allowed elevation above mean sea level
  • max. continuous operating voltage AC
  • short-circuit breaking capacity
  • Valuelist Assembly type
  • Contents per packing unit
  • voltage protection level (L-PE/N-PE)
  • Max. nominal frequency
  • Valuelist suitable for outdoor use
  • minimum ambient temperature (during operation)
  • width of packing
  • Insulation stripped length
  • min. relative humidity (operation)
  • voltage protection level (L-N)
  • Valuelist type of remote indication contact
  • Valuelist characteristic of backup fuse
  • nominal discharge current (8/20) µs (L-PE(N))
  • min. cross-section of the remote indication (rigid)
  • Valuelist SPD type (IEC 61643)
  • max. discharge current (8/20) µs (N-PE)
  • max. discharge current (8/20) µs (L-N)
  • max. discharge current (8/20) µs (L-PE(N))
  • Valuelist number of ports
  • impulse discharge current (10/350) µs (L-N)
  • nominal discharge current (8/20) µs (N-PE)
  • impulse discharge current (10/350) µs (L-PE(N))
  • Valuelist remote indication integrated
  • total discharge current (10/350) µs
  • Valuelist configuration of SPD
  • impulse discharge current (10/350) µs (N-PE)
  • max. cross-section of the remote indication (rigid)
  • Valuelist TOV - behaviour (200 ms)
  • min. cross-section of the remote indication (flexible)
  • Valuelist protective element pluggable
  • Valuelist no leakage current
  • max. cross-section of the remote indication (flexible)
  • Valuelist TOV - behaviour (120 min)
  • Valuelist SPD failure mode
  • max. overcurrent protective device (V-type wiring)
  • max. voltage of remote indication (DC)
  • max. current of remote indication (AC)
  • transition surge current rating
  • max. overcurrent protective device (branch wiring)
  • Integrated overcurrent protective device selective to fuse
  • max. voltage of remote indication (AC)
  • distance to grounded or conductive parts
  • GLN of supplier
  • Supplier product designation
  • Supplier product type
  • product article number of supplier
  • name of supplier
  • Supplier product root
  • Supplier product family
  • Supplier product description
  • Supplier product order suffix
  • Valuelist nominal voltage (for AC)
  • residual current AC
  • Valuelist test standard
  • max. current of remote indication (DC)
  • min. torque (UL 1449)
  • max. torque (UL 1449)
  • Valuelist min. wire cross-section (UL 1449)
  • max. continuous operating voltage AC (L-L)
  • max. continuous operating voltage AC (L-N)
  • voltage protection rating (L-G) (UL 1449)
  • AC power frequency
  • measured limiting voltage (N-G) (UL 1449)
  • Valuelist max. wire cross-section, alarm circuit (UL 1449)
  • measured limiting voltage (L-L) (UL 1449)
  • max. torque, alarm circuit (UL 1449)
  • measured limiting voltage (L-N) (UL 1449)
  • Valuelist max. wire cross-section (UL 1449)
  • measured limiting voltage (L-G) (UL 1449)
  • voltage protection rating (N-G) (UL 1449)
  • min. torque, alarm circuit (UL 1449)
  • Valuelist internal disconnect feature (UL 1449)
  • voltage protection rating (L-L) (UL 1449)
  • Valuelist type of listing (UL 1449)
  • operating voltage, alarm circuit AC (UL 1449)
  • Valuelist number of ports (UL 1449)
  • Valuelist degree of protection (IP) (UL1449)
  • fuse [option 2], voltage (UL 1449)
  • fuse [option 1], class
  • fuse [option 2], current rating (UL 1449)
  • Valuelist SPD Type (UL 1449)
  • Valuelist min. wire cross-section, alarm circuit (UL 1449)
  • fuse [option 1], voltage (UL 1449)
  • fuse [option 1], current rating (UL 1449)
  • fuse [option 2], class
  • max. continuous operating voltage AC (N-G)
  • voltage protection rating (L-N) (UL 1449)
  • short-circuit current rating acc. to UL 1449
  • load current rating AC (UL 1449)
  • min. temperature during operation, °C (UL 1449)
  • max. continuous operating voltage AC (L-G)
  • surge current capacity per phase (UL 1449)
  • max. allowed elevation above mean sea level, m (UL 1449)
  • operating voltage, alarm circuit DC (UL 1449)
  • Valuelist operating voltage AC (UL 1449)
  • max. temperature during operation, °C (UL 1449)
  • nominal discharge current (UL 1449)
  • Valuelist UL Category Code number (UL 1449)
  • AC frequency, alarm circuit (UL 1449)
  • nominal load current, alarm circuit AC (UL1449)
  • nominal load current, alarm circuit DC (UL 1449)
  • Valuelist mode of protection AC (UL 1449)
  • Valuelist service configuration (UL 1449)
  • Valuelist edition of UL 1449 used for testing
  • Valuelist type of load, alarm circuit (UL1449)
  • Min. line cross section, rigid
  • min. temperature during operation, °F (UL 1449)
  • max. temperature during operation, °F (UL 1449)
  • Valuelist mounting method (UL 1449)
  • max. allowed elevation above mean sea level, ft (UL 1449)
  • min. humidity during operation (UL 1449)
  • max. humidity during operation (UL 1449)