在ECLASS标准中搜索

ECLASS 让您有机会免费查看和搜索最新的 ECLASS 版本。 搜索功能直观,让您快速了解标准,不拘泥于官僚主义。

使用 ECLASS 搜索

请首先选择 ...

  • 您想搜索 ECLASS 基本或高级
  • 您想搜索哪个版本
  • 搜索语言
  • 是否要搜索类别或特征、值等。

然后输入搜索词(如 "铅笔"),点击 "搜索"。
 

请注意,使用 ECLASS 标准需要许可证。(另请参阅 ECLASS 使用条款

eclass image

Classification: 27171403 [AHE444001]

Preferred name 27-17-14-03 Combination arrester energy technology PV (type 1+2)
Definition Devices for establishing lightning protection equipotential bonding between the external lightning protection system and the power engineering part of photovoltaic systems designed in DC voltage, which can discharge both lightning currents and surge currents
IRDI 0173-1#01-AHE444#001
Already on the watchlist: 0 of max. 4

BASIC Properties: Combination arrester energy technology PV (type 1+2)

  • Manufacturer product designation
  • GLN of manufacturer
  • URI of the product
  • Product type
  • address of additional link
  • Brand
  • 厂商产品编号
  • EAN代码
  • 制造商名称
  • Manufacturer product root
  • Manufacturer product order suffix
  • Manufacturer product description
  • customs tariff number (TARIC)
  • Manufacturer product family
  • min. cross-section of the remote indication (flexible)
  • max. cross-section of the remote indication (rigid)
  • Valuelist SPD failure mode
  • max. cross-section of the remote indication (flexible)
  • Valuelist test standard
  • residual current DC
  • rated load current
  • Valuelist protective element pluggable
  • max. current of remote indication (DC)
  • Valuelist type of PV system
  • max. permitted DC voltage (UL 1449)
  • measured limiting voltage (DC- - G) (UL 1449)
  • Valuelist min. wire cross-section, alarm circuit (UL 1449)
  • short-circuit current rating acc. to UL 1449
  • operating voltage, alarm circuit AC (UL 1449)
  • Valuelist type of listing (UL 1449)
  • operating voltage PV (UL 1449)
  • Valuelist SPD Type (UL 1449)
  • Valuelist number of ports (UL 1449)
  • leakage current (UL 1449)
  • measured limiting voltage (DC+ - DC-) (UL 1449)
  • max. temperature during operation, °C (UL 1449)
  • min. temperature during operation, °C (UL 1449)
  • Valuelist mode of protection PV (UL 1449)
  • nominal discharge current (UL 1449)
  • Valuelist degree of protection (IP) (UL1449)
  • Valuelist internal disconnect feature (UL 1449)
  • min. torque, alarm circuit (UL 1449)
  • max. torque (UL 1449)
  • min. torque (UL 1449)
  • nominal load current, alarm circuit AC (UL1449)
  • AC frequency, alarm circuit (UL 1449)
  • Valuelist max. wire cross-section (UL 1449)
  • max. torque, alarm circuit (UL 1449)
  • Valuelist min. wire cross-section (UL 1449)
  • operating voltage, alarm circuit DC (UL 1449)
  • nominal load current, alarm circuit DC (UL 1449)
  • Valuelist max. wire cross-section, alarm circuit (UL 1449)
  • max. allowed elevation above mean sea level, m (UL 1449)
  • voltage protection rating (DC- - G) (UL 1449)
  • surge current capacity per phase (UL 1449)
  • Valuelist edition of UL 1449 used for testing
  • measured limiting voltage (DC+ - G) (UL 1449)
  • max. allowed elevation above mean sea level, ft (UL 1449)
  • Valuelist mounting method (UL 1449)
  • voltage protection rating (DC+ - G) (UL 1449)
  • Valuelist type of load, alarm circuit (UL1449)
  • max. humidity during operation (UL 1449)
  • voltage protection rating (DC+ - DC-) (UL 1449)
  • min. humidity during operation (UL 1449)
  • Valuelist UL Category Code number (UL 1449)
  • max. temperature during operation, °F (UL 1449)
  • min. temperature during operation, °F (UL 1449)
  • Valuelist fault indication at device
  • Valuelist UL Approbation available
  • depth
  • Valuelist type of electrical terminal
  • Valuelist 易燃等级
  • 毛重
  • maximum ambient temperature (during operation)
  • height
  • width
  • Valuelist 保护度(IP),已安装
  • length of packing
  • Width in units of measurement
  • 最小相对湿度
  • 绝缘剥离长度
  • width of packing
  • 最大相对湿度
  • 净重
  • nominal discharge current (8/20) µs (DC+ - DC-)
  • Valuelist type of remote indication contact
  • max. discharge current (8/20) µs (DC+ - DC-)
  • max. discharge current (8/20) µs (DC+ - PE)
  • nominal discharge current (8/20) µs (DC- - PE)
  • voltage protection level (DC+ - PE)
  • nominal discharge current (8/20) µs (DC+ - PE)
  • max. discharge current (8/20) µs (DC- - PE)
  • max. voltage of remote indication (AC)
  • short-circuit current rating PV
  • voltage protection level (DC- - PE)
  • min. cross-section of the remote indication (rigid)
  • Valuelist no leakage current
  • max. current of remote indication (AC)
  • max. voltage of remote indication (DC)
  • distance to grounded or conductive parts
  • Valuelist 安装方式
  • voltage protection level (DC+ - DC-)
  • minimum ambient temperature (during operation)
  • Valuelist suitable for outdoor use
  • Valuelist connection method of the remote indication
  • depth of packing
  • Valuelist Approval certificates
  • Contents per packing unit
  • total discharge current (10/350) µs
  • Valuelist remote indication integrated
  • max. continuous operating voltage DC-PV
  • max. allowed elevation above mean sea level
  • impulse discharge current (10/350) µs (DC+ - PE)
  • impulse discharge current (10/350) µs (DC- - PE)
  • Valuelist SPD type (IEC 50539)
  • Valuelist configuration
  • Supplier product order suffix
  • Supplier product description
  • Supplier product family
  • Supplier product root
  • 供货商名称
  • 商品编号
  • Supplier product type
  • Supplier product designation
  • GLN of supplier
  • product identifier