Classification: 27171501 [AHE448003]

Preferred name 27-17-15-01 MSR technology
Definition Devices for the protection of interfaces of measurement and control technology against lightning currents, surge currents and transient overvoltages
Keywords Lightning protection External lightning protection
IRDI 0173-1#01-AHE448#003
Already on the watchlist: 0 of max. 4

BASIC Properties: MSR technology

  • Customs tariff number
  • GLN of supplier
  • Supplier product designation
  • address of additional link
  • Supplier product type
  • product article number of supplier
  • name of supplier
  • Supplier product root
  • Supplier product family
  • Supplier product description
  • Supplier product order suffix
  • Valuelist integrated interrupt mechanism for the signal lines
  • Valuelist protective element pluggable
  • rated current IB
  • series resistance per path
  • min. cross-section of the remote indication (flexible)
  • Valuelist grounding of the reference potential/shielding
  • Valuelist overstressed fault behaviour
  • Valuelist support of multiple interfaces
  • max. capacity (line-line)
  • max. current of remote indication (DC)
  • Valuelist nominal voltage
  • total discharge current (8/20) µs (line-ground) C2
  • Valuelist test standard
  • pulse discharge current (10/350) µs (line) D1
  • max. capacity (line-ground)
  • Valuelist type of remote indication contact
  • Valuelist comparable to SPD type
  • Valuelist test classification (IEC 61643-21)
  • min. cross-section of the remote indication (rigid)
  • max. discharge current (8/20) µs
  • Valuelist remote indication integrated
  • number of protected pairs of wires
  • number of protected single lines
  • max. current of remote indication (AC)
  • Valuelist no leakage current
  • max. cross-section of the remote indication (flexible)
  • max. cross-section of the remote indication (rigid)
  • max. voltage of remote indication (AC)
  • Valuelist type of signal
  • Valuelist grounded via
  • max. voltage of remote indication (DC)
  • minimum ambient temperature (during operation)
  • max. continuous operating voltage AC
  • insertion loss
  • Valuelist Assembly type
  • width of packing
  • Insulation stripped length
  • Valuelist Connection type (1)
  • Valuelist suitable for outdoor use
  • voltage protection level (line-ground) C2
  • voltage protection level (line-line) C2
  • Valuelist connection method of the remote indication
  • max. allowed elevation above mean sea level
  • Contents per packing unit
  • Valuelist Approval certificates
  • depth of packing
  • nominal discharge current (8/20) µs (line) C2
  • GTIN
  • Valuelist Connection type 2
  • height
  • product article number of manufacturer
  • maximum ambient temperature (during operation)
  • Manufacturer product description
  • gross weight
  • GLN of manufacturer
  • Net weight
  • Brand
  • depth
  • Manufacturer name
  • Valuelist fault indication at device
  • Valuelist Degree of protection (IP), mounted
  • width
  • Cut-off frequency
  • Valuelist safety integrity level (SIL)
  • Manufacturer product order suffix
  • max. continuous operating voltage DC
  • Manufacturer product root
  • Valuelist flammability rating of the insulating material (based on UL 94)
  • Manufacturer product family
  • length of packing
  • Valuelist mounting thread
  • Manufacturer product designation
  • Product type
  • Min. line cross section, rigid
  • max. connectable conductor cross-section multiple wire
  • Max. line cross section, rigid
  • min. connectable conductor cross-section multiple wire