在ECLASS标准中搜索

ECLASS 让您有机会免费查看和搜索最新的 ECLASS 版本。 搜索功能直观,让您快速了解标准,不拘泥于官僚主义。

使用 ECLASS 搜索

请首先选择 ...

  • 您想搜索 ECLASS 基本或高级
  • 您想搜索哪个版本
  • 搜索语言
  • 是否要搜索类别或特征、值等。

然后输入搜索词(如 "铅笔"),点击 "搜索"。
 

请注意,使用 ECLASS 标准需要许可证。(另请参阅 ECLASS 使用条款

eclass image

Classification: 27272501 [AGD744006]

Preferred name 27-27-25-01 Incremental safety encoder
Definition Functional safety sensor for generating information about the speed and position of rotational movements. The sensor emits pulses which are interpreted as speed or position information by a control. The position is not uniquely assigned on the measuring element. A reference run can be necessary when switching on the machine. Intended for use in safety applications
Keywords Safety encoder Speed monitor
IRDI 0173-1#01-AGD744#006
Already on the watchlist: 0 of max. 4

BASIC Properties: Incremental safety encoder

  • Cable length
  • Valuelist Reverse polarity protection present
  • height
  • min. temperature of liquid medium
  • Number of poles
  • Valuelist Design of output switching element OSSD
  • max. operating voltage with DC
  • Special characteristics
  • max. operating voltage with AC 60 Hz
  • min. operating voltage with DC
  • min. ambient temperature
  • max. rotation speed
  • width
  • Valuelist certificate/approval
  • type of approval
  • Rated operating voltage Ue with AC
  • Valuelist Size of connection thread
  • min. operating voltage with AC 50 Hz
  • Switching voltage of the OSSD in high state
  • Valuelist Conductor connection method
  • depth
  • min. storage temperature
  • burst pressure
  • max. operating voltage with AC 50 Hz
  • fluid temperature
  • max. storage temperature
  • Application standards
  • min. operating voltage with AC 60 Hz
  • diameter
  • Valuelist IO-Link port type
  • Rated operating voltage Ue with DC
  • Valuelist thread size connector
  • Valuelist product function at IO-Link
  • Valuelist IO-Link transmission rate
  • Valuelist IO-Link device profile
  • IO-Link Min Cycle Time
  • Valuelist IO-Link Revisions-ID
  • IO-Link Process Data Output Length
  • max. temperature of liquid medium
  • Valuelist signal conversion
  • IO-Link Process Data Input Length
  • Valuelist Operating voltage type
  • Valuelist suitable for cable guide chain
  • overload pressure
  • Valuelist Operating resource protection class
  • Valuelist Coding
  • Valuelist cross-circuit detection available
  • Valuelist connection type
  • Valuelist type of connector
  • Valuelist short-circuit strength available
  • Valuelist overload resistance available
  • Valuelist Interface design
  • Valuelist analog output voltage
  • Valuelist output can be inverted
  • Max. output current
  • Max. output current at secured output
  • Valuelist Design of control output
  • Valuelist Design of output signal switching device
  • Valuelist Warning field output present
  • Valuelist type of indication
  • Min. output current
  • compliance to standard(s) or specification
  • PFHD: Probability of dangerous failure per hour
  • Valuelist Safety integrity level
  • max. output frequency
  • Valuelist Service life (standard)
  • GLN of supplier
  • Supplier product designation
  • name of supplier
  • product article number of supplier
  • Supplier product root
  • Supplier product description
  • Supplier product order suffix
  • Supplier product type
  • Supplier product family
  • GLN of manufacturer
  • Brand
  • Manufacturer product description
  • Manufacturer name
  • Manufacturer product family
  • product article number of manufacturer
  • Manufacturer product root
  • Manufacturer product designation
  • Manufacturer product order suffix
  • GTIN
  • Product type
  • Customs tariff number
  • Valuelist Type of customs tariff number
  • HS-Code of the WCO
  • Valuelist Use of customs tariff number
  • Valuelist Explosion protected category for dusts
  • Valuelist programmable
  • Valuelist Performance level acc. to EN ISO 13849-1
  • Valuelist degree of protection
  • address of additional link
  • Valuelist Construction size of shaft encoder
  • Min. number of rotations
  • Mission time
  • Min. diameter of shaft
  • Valuelist material of housing
  • min. number of impulses per revolution
  • max. number of impulses per revolution
  • Valuelist Signal outputs of the shaft encoder
  • Max. number of rotations
  • Max. diameter of shaft
  • Valuelist Physical measurement principle of the sensor
  • Valuelist Design of shaft encoder
  • Valuelist Explosion protection categories for gases