在ECLASS标准中搜索
ECLASS 让您有机会免费查看和搜索最新的 ECLASS 版本。 搜索功能直观,让您快速了解标准,不拘泥于官僚主义。
使用 ECLASS 搜索
请首先选择 ...
- 您想搜索 ECLASS 基本或高级
- 您想搜索哪个版本
- 搜索语言
- 是否要搜索类别或特征、值等。
然后输入搜索词(如 "铅笔"),点击 "搜索"。
请注意,使用 ECLASS 标准需要许可证。(另请参阅 ECLASS 使用条款)
Classification: 36040102 [AAD341019]
Preferred name | 36-04-01-02 Plate heat exchanger |
---|---|
IRDI | 0173-1#01-AAD341#019 |
|
BASIC Properties: Plate heat exchanger
-
Construction type of the connection, muff A2
-
Construction type of the connection, muff B2
-
Type of coating application, room 1
-
Construction type of the connection, muff B1
-
Valuelist construction size
-
Type of coating application, external surface
-
Valuelist conformity declaration present
-
Valuelist designed for alternating loads
-
Min. permissible operating temperature at TS2, room2
-
Max. permissible operating temperature at TS1, room1
-
Max. permissible operating temperature at TS1, room2
-
Type of set-up
-
Type of coating application, room 2
-
Construction type of the connection, muff A1
-
country of manufacturer
-
Valuelist Nominal width of the muffs, A1
-
supplier of the identifier
-
Construction of the connection, muff B2
-
Reference norm material of the heat exchange plate
-
Construction of the heat exchange plate
-
Reference norm material of the coating, room1
-
Valuelist material code of coating (external surface)
-
Construction of the static seal, room2
-
Max. permissible overpressure PS2+ at TS2, room2
-
Wall thickness of the heat exchange plate
-
Max. permissible underpressure PS1- at TS1, room2
-
Max. permissible overpressure PS2+ at TS2, room1
-
Max. permissible underpressure PS2- at TS2, room2
-
Max. permissible underpressure PS1- at TS1, room1
-
Reference norm of the static seal, room2
-
Max. permissible underpressure PS2- at TS2, room1
-
Thermal transfer surface room1/room2
-
Thickness of the coating, room2
-
overall width
-
Construction form of the carrying construction
-
Wall thickness of the press plate
-
design
-
Valuelist explosion protection marking
-
Max. permissible overpressure PS1+ at TS1, room2
-
Valuelist Explosion protection certificate present
-
Valuelist Manufacturer declaration present
-
thickness of coating (external surface)
-
over all height
-
description of class
-
Thickness of the coating, room1
-
Min. permissible operating temperature at TS2, room1
-
overall length
-
Material description of the press plate
-
Volume of the room2
-
Number of supports nominal group 1
-
Reference norm material, design
-
Product country of origin
-
Reference norm of the coating, room2
-
Construction of the connection, muff B1
-
Reference norm material of the carrying construction
-
Valuelist Nominal pressure of the muffs, A2
-
item list number of manufacturer
-
Type description
-
Code of the manufacturer declaration
-
Valuelist Heat exchanger construction type
-
Material number of the press plate
-
Reference norm of the explosion protection
-
Number of supports nominal group 3
-
Material number of the design
-
Material number of the static seal, room2
-
Reference norm material of the press plate
-
Material number of the heat exchange plate
-
Valuelist Construction form of the seal surface, connection, muff A1
-
Material number of the carrying construction
-
Nominal width of the muffs, B1
-
Reference norm the number of muffs
-
Reference norm material of the static seal, room1
-
Volume of the room1
-
Material number of the coating, room1
-
Nominal pressure of the muffs, B2
-
Material description of the carrying construction
-
drawing number of manufacturer
-
Nominal pressure of the muffs, B1
-
Valuelist Nominal width of the muffs, A2
-
Max. permissible operating weight
-
Manufacturer order code
-
Material number of the static seal, room1
-
Construction of the connection, muff A2
-
code of conformity evaluation
-
Material description of the coating, room2
-
material of coating (external surface)
-
Material description of the heat exchange plate
-
Reference norm of the static seal, room1
-
Material description of the coating, room1
-
Reference norm of the connection, muff B2
-
Reference norm material of the frame
-
Valuelist guideline for conformity declaration
-
Construction of the static seal, room1
-
Reference norm of the connection, muff B1
-
Reference norm of the connection, muff A1
-
Construction form of the seal surface, connection, muff B2
-
Material description of the static seal, room1
-
Reference norm of the connection, muff A2
-
Number of heat-exchange plates
-
Material description of the design
-
fabrication number
-
Reference norm of the coating, room1
-
classification system
-
Number of supports nominal group 2
-
Construction form of the seal surface, connection, muff B1
-
Nominal width of the muffs, B2
-
empty weight
-
Reference norm material of the static seal, room2
-
Material description of the frame
-
reference standard for the coating (external surface)
-
Material number of the frame
-
Construction of the connection, muff A1
-
Supplier product description
-
product article number of supplier
-
name of supplier
-
Supplier product designation
-
GLN of supplier
-
Supplier product order suffix
-
Supplier product type
-
Supplier product family
-
Supplier product root
-
Max. permissible overpressure PS1+ at TS1, room1
-
Customs tariff number
-
Valuelist Use of customs tariff number
-
HS-Code of the WCO
-
Valuelist Type of customs tariff number
-
Material description of the static seal, room2
-
code of class
-
Valuelist Nominal pressure of the muffs, A1
-
reference standard
-
reference standard for material of the coating (external surface)
-
Valuelist Construction form of the seal surface, connection, muff A2
-
Material number of the coating, room2
-
Reference norm material of the coating, room2
-
address of additional link
-
Manufacturer product description
-
Brand
-
product article number of manufacturer
-
GTIN
-
Manufacturer name
-
GLN of manufacturer
-
URI of manufacturer
-
Product type
-
URI of the product
-
Manufacturer product family
-
Manufacturer product designation
-
Manufacturer product order suffix
-
Manufacturer product root