Classification: 36410107 [AKN230019]
Preferred name | 36-41-01-07 Fluid draw works/booster pump |
---|---|
IRDI | 0173-1#01-AKN230#019 |
|
BASIC Properties: Fluid draw works/booster pump
-
Valuelist process fluid fault - temperature
-
Valuelist process fluid fault - viscosity
-
Valuelist mechanical fault - brake chopper
-
Valuelist process fluid fault - flow
-
Valuelist auxiliary device fault - sensor element
-
Valuelist pump operation fault - accessory liquid flow
-
Valuelist process fluid fault - solid
-
Valuelist process fluid fault - stall
-
Valuelist auxiliary device fault - wear reserve operation
-
Valuelist auxiliary device fault - parameter setting
-
Valuelist auxiliary device fault - peripheral
-
Valuelist auxiliary device fault - process influence
-
Valuelist software fault - memory
-
Valuelist auxiliary device fault - start up
-
Valuelist auxiliary device fault - temperature shock
-
Valuelist auxiliary device fault - vibration
-
Valuelist electronic fault - winding temperature
-
Valuelist electronic fault - supply voltage
-
Valuelist electronic fault - supply voltage high
-
Valuelist electronic fault - supply voltage low
-
Valuelist process fluid fault - dry
-
corrective maintenance time
-
number of failures
-
severity
-
Valuelist mechanical fault - axial bearing abrasion
-
Valuelist mechanical fault - axial bearing fault
-
Valuelist mechanical fault - axial bearing overheat
-
Valuelist mechanical fault - bearing fault
-
Valuelist mechanical fault - brake overheat
-
Valuelist process fluid fault - gas
-
Valuelist process fluid fault - liquid
-
Valuelist process fluid fault - pressure
-
Valuelist pump operation fault - maximum number starts
-
Valuelist pump operation fault - maximum operation time
-
Valuelist pump operation fault - dirty impeller
-
Valuelist pump operation fault - drive overheat
-
Valuelist mechanical fault - radial bearing abrasion
-
Valuelist mechanical fault - radial bearing fault
-
Valuelist mechanical fault - excess vibration
-
Valuelist pump operation fault - lubricant
-
Valuelist mechanical fault - unbalance
-
Valuelist pump operation fault - accessory liquid low
-
Valuelist mechanical fault - gap wear
-
Valuelist mechanical fault - misalignment
-
Valuelist mechanical fault - radial bearing overheat
-
Valuelist mechanical fault - rotor blocked
-
Valuelist mechanical fault - rotor station rubbing
-
Valuelist pump operation fault - accessory liquid high
-
Valuelist auxiliary device fault - wear reserve wear
-
Valuelist software fault - communication
-
Valuelist electronic fault - armature circuit
-
Valuelist software fault - control
-
Valuelist software fault - parameter
-
Valuelist software fault - software reset
-
Valuelist process fluid fault - blockage
-
Valuelist software fault - application
-
Valuelist pump operation fault - deceleration
-
Valuelist process fluid fault - cavitation
-
Valuelist process fluid fault - condensation
-
Valuelist software fault - OS
-
Valuelist pump operation fault - generator operation
-
Valuelist pump operation fault - leakage
-
Valuelist pump operation fault - coolant low
-
Valuelist pump operation fault - coolant overheat
-
Valuelist pump operation fault - wear reserve exhausted
-
Valuelist auxiliary device fault - actuator element
-
Valuelist auxiliary device fault - ambient temperature
-
Valuelist electronic fault - current inside device
-
Valuelist electronic fault - installation fault
-
Valuelist electronic fault - insulation resistance
-
Valuelist electronic fault - phase failure
-
Valuelist electronic fault - short circuit
-
Valuelist electronic fault - supply current
-
Valuelist electronic fault - supply current high
-
Valuelist electronic fault - supply current low
-
Valuelist auxiliary device fault - auxiliary medium insufficiency
-
Valuelist pump operation fault - motor humidity
-
Valuelist pump operation fault - motor overheat
-
Valuelist pump operation fault - operation fault
-
Valuelist electronic fault - short to earth
-
Valuelist pump operation fault - accessory liquid overheat
-
Valuelist pump operation fault - accessory liquid pressure
-
Valuelist pump operation fault - ambient temperature
-
Valuelist pump operation fault - case overheat
-
Valuelist pump operation fault - converter overheat
-
Valuelist pump operation fault - coolant flow
-
Valuelist pump operation fault - coolant high
-
Valuelist hardware fault - communication
-
Valuelist pump operation fault - under speed
-
Valuelist pump operation fault - velocity limit
-
Valuelist pump operation fault - TMS failure
-
Valuelist pump operation fault - controller overheat
-
Valuelist auxiliary device fault - auxiliary medium absence
-
Valuelist electronic fault - field circuit
-
Valuelist pump operation fault - torque limit
-
Valuelist pump operation fault - turbine operation
-
active preventive maintenance time
-
last servicing date
-
next servicing date
-
lubricating oil consumption
-
sound power
-
mean velocity at inlet
-
number of starts
-
mechanical efficiency
-
leakage rate of flow
-
level
-
overall efficiency
-
power loss due to internal leakage
-
pump efficiency
-
axial load of pump rotor
-
Valuelist pump operation fault - over speed
-
Valuelist pump operation fault - partial load
-
Valuelist pump operation fault - synchronisation
-
Valuelist pump operation fault - maximum starts at time
-
criticality
-
Valuelist pump operation fault - temperature fault
-
Valuelist pump operation fault - time out
-
Valuelist pump operation fault - over load
-
inlet temperature of the pump
-
Valuelist failure
-
preventive maintenance time
-
installation date
-
last inspection date
-
next inspection date
-
sound energy level
-
sound power
-
outlet temperature of the pump
-
design axial load
-
design radial load
-
declaration of conformity
-
sound energy
-
maximum radial load
-
pump curve
-
pump efficiency curve
-
possible fluid
-
min. temperature
-
pump power input curve
-
Valuelist device type
-
maximum axial load
-
pump temperature
-
clearance flow
-
radial load of pump rotor
-
electronic temperature
-
hydraulic efficiency
-
axial rotor position
-
pump power output
-
bearing temperature
-
Speed
-
sound energy
-
housing temperature
-
sound energy level
-
fluid temperature
-
maximum allowable head
-
net positive suction head required
-
pump NPSH curve
-
minimum allowable head
-
net positive suction head required for a drop of 3 %
-
optimum rate of flow
-
leakage rate of flow
-
minimum allowable thermal flow
-
pump H(Q) curve
-
Wet critical speed
-
balancing rate of flow
-
minimum continuous stable flow
-
stable pump H(Q) curve
-
Critical rotational speed
-
minimum continuous thermal flow
-
max. temperature
-
Valuelist supported protocol
-
max. air humidity
-
Control types
-
min. ambient temperature during operation
-
sound pressure level
-
Sound output level
-
Quick-acting speed
-
max. ambient temperature
-
installation NPSH curve
-
Rotational direction of the pump
-
min. air humidity
-
mean rated velocity at inlet
-
total head at inlet area of the pump
-
required control mode
-
height of the inlet side of the installation
-
Valuelist multi-phase
-
height of the pump
-
Valuelist operating mode
-
fluid
-
reference plane
-
gas content
-
max. temperature range
-
mean time between failures (MTBF)
-
min. temperature range
-
height of the outlet side of the installation
-
type number
-
Dry critical rotational speed
-
optimum pump power input
-
Specific rotation speed
-
head at peak point
-
Specific suction speed
-
optimum head
-
Valuelist nominal pressure (PN) of the flange
-
maximum power requirement of the pump
-
Zero flow power requirement
-
height of the inlet connection
-
Nominal size of nozzle/pipe
-
Power factor (cos phi)
-
Max. nominal frequency
-
motor efficiency
-
Nominal speed
-
nominal power consumption
-
enclosure type no/class
-
Min. nominal frequency
-
Valuelist energy efficiency class (motor)
-
nominal voltage
-
norminal frequence
-
Design outlet pressure
-
height of the outlet connection
-
Useful life
-
minimum ambient temperature (during operation)
-
solids volume fraction
-
Valuelist Field bus system
-
Min inlet pressure
-
working temperature
-
maximum ambient temperature (during operation)
-
nominal feed height
-
normal feed flow
-
NPSH-nominal
-
maximum feed height
-
minimum feed height
-
maximum number of pumps in operation
-
exchange time
-
distribution priority
-
Valuelist distribution type
-
ID carrier
-
Number of Pumps
-
exchange time difference
-
category
-
Valuelist direction
-
Coolant temperature
-
Counterpressure
-
Min allowable outet pressure
-
Min allowable inlet pressure
-
inlet area of the pump
-
pump kick time difference
-
Valuelist discrete input value
-
redundant pump Ids
-
Valuelist pump kick mode
-
pump kick time
-
Valuelist exchange mode
-
Valuelist operation mode
-
pump collective Ids
-
Valuelist pump role
-
software version
-
National stock number
-
Valuelist Address of company representative
-
hardware version
-
controller output variable
-
derivative action coefficient
-
final controlled variable
-
integral action coefficient
-
controlled variable
-
device class
-
location
-
day of construction
-
model
-
markings
-
URL
-
product code
-
initial operation date
-
asset ID
-
manufacturer URI
-
type of product
-
component name
-
year of construction
-
month of construction
-
installation total head
-
total head at inlet area of the installation
-
total head at outlet area of the installation
-
Mass flow
-
net positive suction head
-
Instalation outlet pressure
-
Installation inlet pressure
-
lift circulating pump
-
Dynamic viscosity
-
differential pressure
-
kinematic viscosity
-
water pump power consumption
-
mean velocity at throat
-
ambient humidity
-
command variable
-
control difference variable
-
dead time
-
operating mode
-
proportional action coefficient
-
Valuelist on/off
-
Valuelist property-status
-
reference variable
-
feedback variable
-
manipulated variable
-
Manufacturer order code
-
set operation mode
-
set control mode
-
Density
-
Valuelist actual control mode
-
Valuelist actual operation mode
-
Valuelist control inversion
-
Valuelist enable
-
on off cycle
-
Valuelist external signal
-
Valuelist reverse rotating direction
-
Valuelist fault action
-
fault value
-
Valuelist discrete output value
-
Load moment of the drive
-
Operation type time sequence of the drive
-
Rotational direction of the drive
-
Type of set-up
-
Type of coating application, room 1
-
Construction type of the connection, muff A2
-
Construction type of the connection, muff A1
-
country of manufacturer
-
Valuelist Heater/cooler present
-
Valuelist Regenerative design
-
Valuelist construction size
-
Valuelist Type of drive
-
Moment of inertia of the drive
-
Valuelist Explosion protection certificate present
-
Valuelist Manufacturer declaration present
-
Valuelist conformity declaration present
-
Max. permissible operating temperature at TS1, room2
-
Min. permissible operating temperature at TS2, room2
-
material of housing
-
material code of housing
-
type of dynamic seal
-
Max. permissible operating temperature at TS1, room1
-
Valuelist Controllable
-
width over all, base plate
-
Max. speed of the drive
-
Height over all, base plate
-
Valuelist explosion protection marking
-
Max. permissible overpressure PS1+ at TS1, room2
-
Thickness of the coating, room1
-
Zero-delivery height
-
supplier of the identifier
-
Construction of the static seal, housing
-
Max. permissible overpressure PS2+ at TS2, room1
-
Max. permissible overpressure PS2+ at TS2, room2
-
Construction of the transmission
-
Reference norm material of the coating, room1
-
Reference norm of the explosion protection of the electric motor
-
Valuelist Nominal width of the muffs, A1
-
Min. permissible operating temperature at TS2, room1
-
overall length
-
description of class
-
over all height
-
Construction form of the transmission
-
Construction form of the housing
-
Construction form of the travel wheel
-
Length over all, base plate
-
External diameter of the travel wheel
-
design
-
overall width
-
Construction form of the electric motor
-
Min. speed of the drive
-
Nominal speed of the drive
-
Elevation of setting of the machine sets, suction-side
-
Measurement speed of the electric motor
-
material code of dynamic seal
-
Valuelist Construction type
-
Measurement tension of the electric motor
-
material code of dynamic seal
-
Class code of the electric motor
-
Classification system of the transmission
-
Explosion protection Type of 'e' protection of the electric motor
-
Reference norm material of the can
-
Torque at nominal speed, drive
-
Reference norm of the static seal, housing
-
Material description of the drive housing
-
Reference norm of the explosion protection
-
Reference norm material of the travel wheel
-
Reference norm material of the drive housing
-
Initial breakaway torque of the drive
-
Product country of origin
-
drawing number of manufacturer
-
Material number of the coating, room1
-
Type of the seal
-
Material number of the drive housing
-
Valuelist Construction form of the seal surface, connection, muff A1
-
Explosion protection device group of the electric motor
-
reference standard for material of the housing
-
Valuelist Nominal width of the muffs, A2
-
item list number of manufacturer
-
Classification system of the electric motor
-
reference standard for the dynamic seal
-
Construction of the electric motor
-
Type description
-
Code of the manufacturer declaration
-
design of dynamic seal
-
Valuelist Nominal pressure of the muffs, A2
-
Material description of the coating, room1
-
Valuelist Material number of the static seal, housing
-
Material description of the travel wheel
-
Shaft performance for nominal speed, drive
-
Protection type class of the electric motor
-
Material number of the can
-
Max. feed flow
-
Valuelist guideline for conformity declaration
-
Material description of the can
-
Construction of the connection, muff A2
-
code of conformity evaluation
-
Reference norm of the connection, muff A1
-
Valuelist Nominal pressure of the muffs, A1
-
Valuelist Construction form of the seal surface, connection, muff A2
-
reference standard
-
code of class
-
Explosion protection temperature class of the electric motor
-
Material description of the static seal, housing
-
Measurement performance of the electric motor
-
Explosion protection code of the electric motor
-
Construction of the connection, muff A1
-
Transmission ratio of the transmission
-
Class code of the transmission
-
empty weight
-
Reference norm of the connection, muff A2
-
Explosion protection category for devices , electric motor
-
material of dynamic seal
-
Reference norm material of the static seal, housing
-
classification system
-
fabrication number
-
Reference norm of the coating, room1
-
Reference norm protection type of electric motor
-
Supplier product root
-
Supplier product order suffix
-
Supplier product type
-
GLN of supplier
-
name of supplier
-
Supplier product description
-
Supplier product family
-
Supplier product designation
-
product article number of supplier
-
Max. permissible underpressure PS1- at TS1, room2
-
Valuelist Material number of the travel wheel
-
Number of levels
-
Min. feed flow
-
Max. permissible overpressure PS1+ at TS1, room1
-
Max. permissible underpressure PS2- at TS2, room1
-
Max. permissible underpressure PS2- at TS2, room2
-
Max. permissible underpressure PS1- at TS1, room1
-
Valuelist Construction form of the coupling
-
Max. overpressure of the shaft seal
-
Customs tariff number
-
Valuelist Type of customs tariff number
-
Valuelist Use of customs tariff number
-
HS-Code of the WCO
-
GTIN
-
address of additional link
-
URI of the product
-
GLN of manufacturer
-
URI of manufacturer
-
Manufacturer product root
-
Manufacturer product family
-
Manufacturer product designation
-
Product type
-
Manufacturer product description
-
Brand
-
Manufacturer product order suffix
-
Manufacturer name
-
product article number of manufacturer
-
Explosion protection device group of the pump
-
Explosion protection explosion group of the pump
-
Explosion protection Type of 'e' protection of the pump
-
density
-
vapor pressure (gauge)
-
total head at inlet area of the installation
-
mean repair time
-
standby time
-
Valuelist state of the item
-
failure rate
-
idle time
-
up time
-
Valuelist maintenance level
-
maintenance time
-
Explosion protection code of the pump
-
Object identifier within a plant
-
Explosion protection category for devices, pump
-
Explosion protection temperature class of the pump
-
pump total head
-
Explosion protection Equipment Protection Level (EPL) of the pump
-
Explosion protection Equipment Protection Level (EPL) of the pump
-
Explosion protection explosion group of the electric motor
-
Design differential pressure
-
mean rated velocity at outlet area of the installation
-
height of the NPSH datum plane
-
installation total head
-
total head at outlet area of the installation
-
net positive suction head available
-
kinematic viscosity
-
mean rated velocity at inlet area of the installation
-
overall efficiency
-
maximum dynamic sealing pressure
-
height of the outlet manometer
-
hydraulic efficiency
-
pump rated power input
-
mechanical efficiency
-
minimum allowable stable flow
-
useful life
-
pump best efficiency
-
pump efficiency
-
pump mechanical power losses
-
mean velocity at outlet
-
operating time between failures
-
operating time to failure
-
active maintenance time
-
time to restoration
-
down time
-
external disabled time
-
mean time to restauration
-
operating time
-
mean downtime
-
repair time
-
atmospheric pressure
-
height of the inlet manometer
-
maintainability
-
operational reliability
-
production based availability
-
intrinsic reliability
-
time based availability
-
availability
-
durability
-
expected reliability
-
instantaneous availability
-
Valuelist obsolescence
-
intrinsic maintainability
-
Valuelist auxiliary device fault - humidity electronics
-
Valuelist auxiliary device fault - installation
-
Reliability according to norm
-
voltage
-
DC link voltage
-
driver power input
-
current
-
energy consumption
-
frequency
-
motor current
-
motor temperature
-
motor voltage
-
power factor
-
torque
-
total head at outlet area of the pump
-
mean rated velocity at outlet
-
DC link current
-
Valuelist auxiliary device fault - auxiliary power pole
-
Valuelist auxiliary device fault - auxiliary power range
-
Valuelist hardware fault - power supply
-
Valuelist hardware fault - ram
-
Valuelist auxiliary device fault - communication error
-
Valuelist auxiliary device fault - corrosion
-
Valuelist auxiliary device fault - deviation
-
Valuelist auxiliary device fault - electromagnetic interference
-
Valuelist auxiliary device fault - evaluation electronics
-
Valuelist electronic fault - supply frequency high
-
Valuelist auxiliary device fault - exciter error
-
Valuelist electronic fault - supply frequency low
-
Valuelist electronic fault - voltage inside device
-
Valuelist auxiliary device fault - electronic fault
-
Valuelist auxiliary device fault - energy supply
-
Valuelist electronic fault - supply frequency
-
Valuelist auxiliary device fault - line length
-
Valuelist auxiliary device fault - material electronics
-
Valuelist auxiliary device fault - measured material electronics
-
Valuelist auxiliary device fault - fouling
-
Valuelist hardware fault - control circuit
-
Valuelist auxiliary device fault - overloading
-
Valuelist hardware fault - DC link supply
-
Valuelist auxiliary device fault - interruption
-
Valuelist hardware fault - network NA
-
Valuelist auxiliary device fault - mechanical damage
-
Valuelist hardware fault - computing circuit
-
Valuelist auxiliary device fault - operating conditions
-
Valuelist hardware fault - uP
-
Valuelist hardware fault - eprom
-
Valuelist hardware fault - IONA
-
Valuelist hardware fault - measure circuit