在ECLASS标准中搜索

ECLASS 让您有机会免费查看和搜索最新的 ECLASS 版本。 搜索功能直观,让您快速了解标准,不拘泥于官僚主义。

使用 ECLASS 搜索

请首先选择 ...

  • 您想搜索 ECLASS 基本或高级
  • 您想搜索哪个版本
  • 搜索语言
  • 是否要搜索类别或特征、值等。

然后输入搜索词(如 "铅笔"),点击 "搜索"。
 

请注意,使用 ECLASS 标准需要许可证。(另请参阅 ECLASS 使用条款

eclass image

Classification: 36410190 [AKL849019]

Preferred name 36-41-01-90 Centrifugal pump (unspecified)
Definition Sub-group (4th level) for objects that cannot be classified into other specified sub-groups in the existing structure, but that are classified to their parent-class on the 3rd level
IRDI 0173-1#01-AKL849#019
Already on the watchlist: 0 of max. 4

BASIC Properties: Centrifugal pump (unspecified)

  • installation NPSH curve
  • minimum allowable head
  • height of the inlet connection
  • pump NPSH curve
  • net positive suction head required
  • minimum allowable thermal flow
  • leakage rate of flow
  • optimum rate of flow
  • balancing rate of flow
  • maximum allowable head
  • net positive suction head required for a drop of 3 %
  • maximum axial load
  • sound power
  • maximum radial load
  • minimum inlet pressure
  • height of the outlet connection
  • rated outlet pressure
  • total head at inlet area of the pump
  • mean rated velocity at inlet
  • Valuelist supported protocol
  • max. ambient temperature
  • max. temperature
  • sound pressure level
  • Rotational direction of the pump
  • min. air humidity
  • max. air humidity
  • Control types
  • Valuelist multi-phase
  • fluid
  • required control mode
  • gas content
  • Valuelist operating mode
  • height of the inlet side of the installation
  • design axial load
  • sound energy level
  • declaration of conformity
  • design radial load
  • pump efficiency curve
  • pump curve
  • sound energy
  • possible fluid
  • min. temperature
  • Sound output level
  • Valuelist device type
  • pump power input curve
  • min. ambient temperature during operation
  • Valuelist Controllable
  • Quick-acting speed
  • minimum continuous stable flow
  • specific speed
  • wet critical speed
  • stable pump H(Q) curve
  • critical speed
  • type number
  • pump H(Q) curve
  • minimum continuous thermal flow
  • optimum head
  • suction-specific speed
  • order code of manufacturer
  • height of the pump
  • Valuelist Field bus system
  • reference plane
  • height of the outlet side of the installation
  • working temperature
  • max. temperature range
  • solids volume fraction
  • mean time between failures (MTBF)
  • maximum ambient temperature (during operation)
  • minimum ambient temperature (during operation)
  • Useful life
  • min. temperature range
  • dry critical speed
  • head at peak point
  • optimum pump power input
  • material code of housing
  • material of housing
  • Min. work temperature
  • type of dynamic seal
  • Operation type time sequence of the drive
  • Load moment of the drive
  • Type of set-up
  • Rotational direction of the drive
  • Construction type of the connection, muff A2
  • Type of coating application, room 1
  • country of manufacturer
  • Construction type of the connection, muff A1
  • Valuelist Regenerative design
  • Valuelist Heater/cooler present
  • Valuelist Type of drive
  • Valuelist construction size
  • Max. permissible operating temperature at TS1, room1
  • Max. work temperature
  • Min. permissible operating temperature at TS2, room2
  • Max. permissible operating temperature at TS1, room2
  • Design temperature
  • NPSH-nominal
  • Construction form of the electric motor
  • overall width
  • Volume flow of the sealing liquid
  • Zero flow power requirement
  • minimum dynamic viscosity at design temperature
  • maximum dynamic viscosity at design temperature
  • Filling volume of the equipment
  • normal feed flow
  • minimum power requirement of the pump
  • maximum power requirement of the pump
  • minimum feed height
  • Measurement speed of the electric motor
  • design
  • External diameter of the travel wheel
  • Valuelist Explosion protection certificate present
  • description of class
  • Valuelist conformity declaration present
  • Valuelist Manufacturer declaration present
  • overall length
  • Min. permissible operating temperature at TS2, room1
  • Moment of inertia of the drive
  • over all height
  • maximum feed height
  • maximum permissible outside diameter of the impeller
  • Thickness of the coating, room1
  • NPSH at minimum feed flow
  • NPSH at maximum feed flow
  • Construction form of the transmission
  • Construction form of the travel wheel
  • Construction form of the housing
  • Max. permissible underpressure PS1- at TS1, room1
  • Valuelist Sealing type
  • Length over all, base plate
  • Max. permissible underpressure PS1- at TS1, room2
  • supplier of the identifier
  • Reference norm of the explosion protection of the electric motor
  • Construction of the static seal, housing
  • Material number of the secondary sealing element
  • Construction of the transmission
  • Material number of the drive housing
  • Valuelist Nominal width of the muffs, A1
  • Reference norm material of the coating, room1
  • Type of the seal
  • Material number of the coating, room1
  • Material number of the stator
  • Material description of the shaft
  • Height over all, base plate
  • Min. speed of the drive
  • Elevation of setting of the machine sets, suction-side
  • Nominal speed of the drive
  • Rotation speed pump
  • minimum density at design temperature
  • minimum permissible outside diameter of the impeller
  • Max. speed of the drive
  • Zero-delivery height
  • nominal feed height
  • maximum density at design temperature
  • width over all, base plate
  • Max. permissible overpressure PS2+ at TS2, room2
  • Max. permissible overpressure PS2+ at TS2, room1
  • Max. permissible overpressure PS1+ at TS1, room2
  • Valuelist explosion protection marking
  • Measurement tension of the electric motor
  • Reference norm of the can material
  • Type description
  • material code of dynamic seal
  • Material description of the can
  • Reference norm material of the can
  • Material description of the secondary sealing element
  • Valuelist Construction type
  • Classification system of the transmission
  • Reference norm of the explosion protection
  • material code of dynamic seal
  • Explosion protection Type of 'e' protection of the electric motor
  • Material description of the drive housing
  • Material number of the can
  • Class code of the electric motor
  • Reference norm material of the shaft protection sleeve
  • Manufacturer's name of the sealing
  • reference standard for material of the housing
  • drawing number of manufacturer
  • Valuelist Nominal width of the muffs, A2
  • Construction of the electric motor
  • Reference norm of the secondary sealing element material
  • Explosion protection device group of the electric motor
  • Valuelist Construction form of the seal surface, connection, muff A1
  • item list number of manufacturer
  • Valuelist Nominal pressure of the muffs, A2
  • reference standard for the dynamic seal
  • Classification system of the electric motor
  • Code of the manufacturer declaration
  • Material description of the statorpipe
  • Reference norm material of the shaft
  • design of dynamic seal
  • Class code of the transmission
  • Transmission ratio of the transmission
  • empty weight
  • Valuelist Material number of the shaft
  • material of dynamic seal
  • Explosion protection category for devices , electric motor
  • Construction of the connection, muff A1
  • Reference norm material of the static seal, housing
  • Reference norm of the coating, room1
  • Year of construction
  • Reference norm of the connection, muff A2
  • Reference norm protection type of electric motor
  • fabrication number
  • classification system
  • Material number of the plain bearing bush
  • Valuelist Material number of the containment shroud
  • Material description of the stator
  • Product country of origin
  • Reference norm of the static seal, housing
  • Torque at nominal speed, drive
  • Reference norm material of the travel wheel
  • Explosion protection code of the electric motor
  • Initial breakaway torque of the drive
  • Reference norm material of the drive housing
  • Material number of the statorpipe
  • Material number of the shaft protective sleeve
  • Material number of the pumping medium
  • Measurement performance of the electric motor
  • Explosion protection temperature class of the electric motor
  • Material description of the pumping medium
  • Reference norm material of the stator
  • Material description of the static seal, housing
  • Material description of the containment shroud
  • code of class
  • Type description of the sealing
  • Material description of the can
  • Valuelist Construction form of the seal surface, connection, muff A2
  • Valuelist Nominal pressure of the muffs, A1
  • Material description of the plain bearing bush
  • reference standard
  • Valuelist Material number of the travel wheel
  • Max. permissible underpressure PS2- at TS2, room2
  • Min. feed flow
  • Number of levels
  • Max. overpressure of the shaft seal
  • Valuelist Construction form of the coupling
  • Max. permissible underpressure PS2- at TS2, room1
  • Max. permissible overpressure PS1+ at TS1, room1
  • Material description of the travel wheel
  • Valuelist Material number of the static seal, housing
  • Reference norm material, pumping medium
  • Shaft performance for nominal speed, drive
  • Valuelist guideline for conformity declaration
  • Max. feed flow
  • Material description of the shaft protection sleeve
  • Material description of the coating, room1
  • Reference norm of the statorpipe material
  • Protection type class of the electric motor
  • Material number of the can
  • Reference norm of the plain bearing bush material
  • code of conformity evaluation
  • Construction of the connection, muff A2
  • Reference norm of the containment shroud material
  • Reference norm of the connection, muff A1
  • product article number of supplier
  • Supplier product designation
  • GLN of manufacturer
  • URI of the product
  • URI of manufacturer
  • Manufacturer product family
  • Manufacturer product root
  • Product type
  • Manufacturer product designation
  • Manufacturer product description
  • Manufacturer product order suffix
  • Brand
  • Valuelist Use of customs tariff number
  • Valuelist Type of customs tariff number
  • Customs tariff number
  • HS-Code of the WCO
  • Supplier product order suffix
  • Supplier product root
  • GLN of supplier
  • Supplier product type
  • name of supplier
  • Supplier product family
  • Supplier product description
  • Manufacturer name
  • product article number of manufacturer
  • GTIN
  • address of additional link
  • Explosion protection Equipment Protection Level (EPL) of the pump
  • Explosion protection Equipment Protection Level (EPL) of the pump
  • Explosion protection temperature class of the pump
  • Explosion protection explosion group of the electric motor
  • torque
  • power factor
  • voltage
  • current
  • DC link voltage
  • frequency
  • DC link current
  • driver power input
  • motor current
  • motor voltage
  • energy consumption
  • Explosion protection Type of 'e' protection of the pump
  • Explosion protection explosion group of the pump
  • Explosion protection code of the pump
  • Explosion protection device group of the pump
  • Explosion protection category for devices, pump
  • Object identifier within a plant
  • pump temperature
  • hydraulic efficiency
  • radial load of pump rotor
  • clearance flow
  • sound energy
  • power loss due to internal leakage
  • sound energy level
  • housing temperature
  • fluid temperature
  • overall efficiency
  • outlet temperature of the pump
  • Speed
  • mean velocity at outlet
  • motor temperature
  • mechanical efficiency
  • number of starts
  • lubricating oil consumption
  • level
  • axial load of pump rotor
  • pump efficiency
  • sound power
  • leakage rate of flow
  • axial rotor position
  • electronic temperature
  • bearing temperature
  • pump power output
  • kinematic viscosity
  • mean rated velocity at outlet area of the installation
  • pump total head
  • installation total head
  • total head at outlet area of the installation
  • total head at inlet area of the installation
  • rated differential pressure
  • mean rated velocity at inlet area of the installation
  • vapor pressure (gauge)
  • height of the NPSH datum plane
  • density
  • overall efficiency
  • useful life
  • next servicing date
  • last servicing date
  • next inspection date
  • last inspection date
  • installation date
  • preventive maintenance time
  • active preventive maintenance time
  • mean rated velocity at outlet
  • total head at outlet area of the pump
  • mean velocity at inlet
  • net positive suction head available
  • Valuelist pump operation fault - coolant overheat
  • Valuelist pump operation fault - drive overheat
  • Valuelist pump operation fault - coolant flow
  • Valuelist pump operation fault - deceleration
  • Valuelist pump operation fault - generator operation
  • Valuelist pump operation fault - maximum number starts
  • Valuelist pump operation fault - dirty impeller
  • Valuelist pump operation fault - leakage
  • Valuelist pump operation fault - maximum operation time
  • Valuelist pump operation fault - operation fault
  • Valuelist pump operation fault - lubricant
  • Valuelist pump operation fault - coolant low
  • Valuelist pump operation fault - over load
  • Valuelist pump operation fault - synchronisation
  • Valuelist pump operation fault - motor overheat
  • Valuelist pump operation fault - over speed
  • pump rated power input
  • pump mechanical power losses
  • pump efficiency
  • pump best efficiency
  • minimum allowable stable flow
  • mechanical efficiency
  • hydraulic efficiency
  • maximum dynamic sealing pressure
  • height of the outlet manometer
  • height of the inlet manometer
  • atmospheric pressure
  • Valuelist pump operation fault - coolant high
  • Valuelist process fluid fault - stall
  • Valuelist process fluid fault - solid
  • Valuelist process fluid fault - pressure
  • Valuelist process fluid fault - liquid
  • number of failures
  • Valuelist mechanical fault - axial bearing fault
  • corrective maintenance time
  • severity
  • Valuelist process fluid fault - temperature
  • Valuelist pump operation fault - accessory liquid flow
  • Valuelist mechanical fault - axial bearing abrasion
  • Valuelist process fluid fault - viscosity
  • Valuelist pump operation fault - accessory liquid high
  • Valuelist mechanical fault - rotor station rubbing
  • Valuelist pump operation fault - accessory liquid low
  • Valuelist mechanical fault - unbalance
  • Valuelist pump operation fault - temperature fault
  • Valuelist pump operation fault - motor humidity
  • Valuelist pump operation fault - partial load
  • Valuelist pump operation fault - time out
  • Valuelist software fault - software reset
  • Valuelist process fluid fault - condensation
  • Valuelist pump operation fault - maximum starts at time
  • Valuelist process fluid fault - blockage
  • Valuelist mechanical fault - bearing fault
  • Valuelist mechanical fault - axial bearing overheat
  • Valuelist process fluid fault - cavitation
  • Valuelist process fluid fault - dry
  • Valuelist process fluid fault - flow
  • Valuelist mechanical fault - brake chopper
  • Valuelist process fluid fault - gas
  • Valuelist mechanical fault - brake overheat
  • Valuelist auxiliary device fault - material electronics
  • Valuelist auxiliary device fault - operating conditions
  • Valuelist electronic fault - winding temperature
  • Valuelist auxiliary device fault - measured material electronics
  • Valuelist hardware fault - DC link supply
  • Valuelist auxiliary device fault - overloading
  • Valuelist hardware fault - computing circuit
  • Valuelist auxiliary device fault - mechanical damage
  • Valuelist hardware fault - eprom
  • Valuelist auxiliary device fault - fouling
  • Valuelist hardware fault - control circuit
  • Valuelist hardware fault - IONA
  • Valuelist auxiliary device fault - line length
  • Valuelist auxiliary device fault - interruption
  • Valuelist auxiliary device fault - installation
  • Valuelist auxiliary device fault - humidity electronics
  • Valuelist hardware fault - communication
  • Valuelist pump operation fault - case overheat
  • Valuelist pump operation fault - accessory liquid pressure
  • Valuelist pump operation fault - accessory liquid overheat
  • Valuelist pump operation fault - controller overheat
  • Valuelist mechanical fault - excess vibration
  • Valuelist pump operation fault - ambient temperature
  • Valuelist pump operation fault - converter overheat
  • Valuelist mechanical fault - radial bearing fault
  • Valuelist mechanical fault - radial bearing abrasion
  • Valuelist mechanical fault - misalignment
  • Valuelist mechanical fault - gap wear
  • Valuelist electronic fault - voltage inside device
  • Valuelist electronic fault - supply voltage low
  • Valuelist mechanical fault - rotor blocked
  • Valuelist mechanical fault - radial bearing overheat
  • Valuelist auxiliary device fault - process influence
  • Valuelist auxiliary device fault - temperature shock
  • Valuelist auxiliary device fault - parameter setting
  • Valuelist auxiliary device fault - sensor element
  • Valuelist pump operation fault - under speed
  • Valuelist auxiliary device fault - actuator element
  • Valuelist auxiliary device fault - start up
  • Valuelist pump operation fault - velocity limit
  • Valuelist auxiliary device fault - auxiliary medium absence
  • Valuelist electronic fault - current inside device
  • Valuelist pump operation fault - wear reserve exhausted
  • Valuelist electronic fault - field circuit
  • Valuelist electronic fault - installation fault
  • Valuelist auxiliary device fault - auxiliary medium insufficiency
  • Valuelist auxiliary device fault - ambient temperature
  • Valuelist electronic fault - insulation resistance
  • Valuelist hardware fault - ram
  • Valuelist hardware fault - power supply
  • Valuelist hardware fault - network NA
  • Valuelist hardware fault - measure circuit
  • Valuelist auxiliary device fault - vibration
  • Valuelist electronic fault - armature circuit
  • Valuelist hardware fault - uP
  • Valuelist auxiliary device fault - wear reserve operation
  • Valuelist software fault - application
  • Valuelist software fault - memory
  • Valuelist software fault - communication
  • Valuelist auxiliary device fault - wear reserve wear
  • Valuelist software fault - OS
  • Valuelist auxiliary device fault - peripheral
  • Valuelist software fault - control
  • Valuelist software fault - parameter
  • Valuelist electronic fault - supply voltage high
  • Valuelist electronic fault - supply voltage
  • Valuelist electronic fault - supply frequency high
  • Valuelist auxiliary device fault - evaluation electronics
  • Valuelist auxiliary device fault - corrosion
  • Valuelist auxiliary device fault - communication error
  • Valuelist auxiliary device fault - auxiliary power range
  • Valuelist auxiliary device fault - auxiliary power pole
  • inlet temperature of the pump
  • criticality
  • Valuelist failure
  • availability
  • durability
  • Valuelist pump operation fault - torque limit
  • Valuelist electronic fault - short circuit
  • Valuelist pump operation fault - TMS failure
  • Valuelist pump operation fault - turbine operation
  • Valuelist electronic fault - short to earth
  • Valuelist electronic fault - supply current low
  • Valuelist electronic fault - phase failure
  • Valuelist electronic fault - supply current
  • Valuelist auxiliary device fault - deviation
  • Valuelist electronic fault - supply frequency
  • Valuelist electronic fault - supply current high
  • Valuelist auxiliary device fault - electromagnetic interference
  • Valuelist electronic fault - supply frequency low
  • Valuelist auxiliary device fault - exciter error
  • Valuelist auxiliary device fault - energy supply
  • Valuelist auxiliary device fault - electronic fault
  • down time
  • repair time
  • operating time between failures
  • external disabled time
  • standby time
  • Valuelist maintenance level
  • failure rate
  • Valuelist state of the item
  • time to restoration
  • up time
  • idle time
  • total head at outlet area of the installation
  • mean downtime
  • operating time
  • intrinsic reliability
  • intrinsic maintainability
  • instantaneous availability
  • expected reliability
  • operational reliability
  • time based availability
  • maintainability
  • production based availability
  • mean repair time
  • maintenance time
  • Reliability according to norm
  • active maintenance time
  • operating time to failure
  • Valuelist obsolescence
  • mean time to restauration
  • ambient humidity
  • mean velocity at throat
  • Coolant temperature
  • on off cycle
  • Density
  • water pump power consumption
  • set operation mode
  • Valuelist actual operation mode
  • Valuelist control inversion
  • Valuelist reverse rotating direction
  • Valuelist enable
  • installation total head
  • inlet pressure of the installation
  • total head at inlet area of the installation
  • net positive suction head
  • differential pressure
  • Dynamic viscosity
  • outlet pressure of the installation
  • Mass flow
  • lift circulating pump
  • kinematic viscosity
  • Counterpressure
  • Valuelist discrete output value
  • manufacturer URI
  • device class
  • model
  • type of product
  • month of construction
  • year of construction
  • product code
  • URL
  • Valuelist Address of company representative
  • hardware version
  • software version
  • National stock number
  • fault value
  • Valuelist fault action
  • Valuelist external signal
  • Valuelist property-status
  • asset ID
  • initial operation date
  • location
  • markings
  • component name
  • day of construction
  • Valuelist pump kick mode
  • pump kick time difference
  • dead time
  • Valuelist discrete input value
  • pump kick time
  • inlet area of the pump
  • minimum allowable inlet pressure
  • ID carrier
  • Valuelist direction
  • category
  • integral action coefficient
  • proportional action coefficient
  • manipulated variable
  • command variable
  • reference variable
  • operating mode
  • control difference variable
  • derivative action coefficient
  • controller output variable
  • set control mode
  • controlled variable
  • feedback variable
  • Valuelist actual control mode
  • Valuelist on/off
  • final controlled variable
  • Valuelist nominal pressure (PN) of the flange
  • Min. nominal frequency
  • enclosure type no/class
  • motor efficiency
  • Max. nominal frequency
  • Power factor (cos phi)
  • Valuelist energy efficiency class (motor)
  • nominal voltage
  • Nominal speed
  • nominal power consumption
  • norminal frequence
  • distribution priority
  • Valuelist exchange mode
  • redundant pump Ids
  • Valuelist pump role
  • maximum number of pumps in operation
  • exchange time difference
  • Valuelist distribution type
  • exchange time
  • Number of Pumps
  • pump collective Ids
  • Valuelist operation mode
  • Nominal size of nozzle/pipe
  • minimum allowable outet pressure
X

We need your consent

This website uses necessary cookies to ensure the operation of the website. There is no analysis of user behavior by third parties. You can find detailed information about the use of cookies in our privacy policy.