在ECLASS标准中搜索

ECLASS 让您有机会免费查看和搜索最新的 ECLASS 版本。 搜索功能直观,让您快速了解标准,不拘泥于官僚主义。

使用 ECLASS 搜索

请首先选择 ...

  • 您想搜索 ECLASS 基本或高级
  • 您想搜索哪个版本
  • 搜索语言
  • 是否要搜索类别或特征、值等。

然后输入搜索词(如 "铅笔"),点击 "搜索"。
 

请注意,使用 ECLASS 标准需要许可证。(另请参阅 ECLASS 使用条款

eclass image

Classification: 36410305 [AAZ378021]

Preferred name 36-41-03-05 Screw pump
Keywords Pump (screw) Screw pump w. magnetic coupling
IRDI 0173-1#01-AAZ378#021
Already on the watchlist: 0 of max. 4

BASIC Properties: Screw pump

  • Explosion protection category for devices, pump
  • Explosion protection temperature class of the pump
  • Explosion protection code of the pump
  • Object identifier within a plant
  • Explosion protection Type of 'e' protection of the pump
  • Explosion protection device group of the pump
  • Explosion protection explosion group of the pump
  • height of the NPSH datum plane
  • installation total head
  • Design differential pressure
  • mean rated velocity at outlet area of the installation
  • Explosion protection Equipment Protection Level (EPL) of the pump
  • Explosion protection explosion group of the electric motor
  • pump total head
  • Explosion protection Equipment Protection Level (EPL) of the pump
  • vapor pressure (gauge)
  • total head at inlet area of the installation
  • density
  • kinematic viscosity
  • mean rated velocity at inlet area of the installation
  • total head at outlet area of the installation
  • net positive suction head available
  • Valuelist direction
  • ID carrier
  • category
  • pump best efficiency
  • frequency
  • motor current
  • current
  • energy consumption
  • DC link voltage
  • driver power input
  • voltage
  • DC link current
  • total head at outlet area of the pump
  • mean rated velocity at outlet
  • power factor
  • torque
  • motor temperature
  • motor voltage
  • availability
  • durability
  • intrinsic reliability
  • time based availability
  • production based availability
  • maintainability
  • operational reliability
  • Reliability according to norm
  • Valuelist auxiliary device fault - installation
  • Valuelist obsolescence
  • intrinsic maintainability
  • expected reliability
  • instantaneous availability
  • Valuelist auxiliary device fault - interruption
  • Valuelist auxiliary device fault - line length
  • Valuelist auxiliary device fault - overloading
  • Valuelist hardware fault - DC link supply
  • Valuelist auxiliary device fault - fouling
  • Valuelist auxiliary device fault - humidity electronics
  • Valuelist auxiliary device fault - material electronics
  • Valuelist auxiliary device fault - measured material electronics
  • Valuelist hardware fault - measure circuit
  • Valuelist hardware fault - network NA
  • Valuelist hardware fault - eprom
  • Valuelist hardware fault - IONA
  • Valuelist auxiliary device fault - operating conditions
  • Valuelist hardware fault - control circuit
  • Valuelist auxiliary device fault - mechanical damage
  • Valuelist hardware fault - computing circuit
  • Valuelist auxiliary device fault - electromagnetic interference
  • Valuelist auxiliary device fault - auxiliary power pole
  • Valuelist auxiliary device fault - corrosion
  • Valuelist auxiliary device fault - deviation
  • Valuelist hardware fault - ram
  • Valuelist hardware fault - uP
  • Valuelist auxiliary device fault - auxiliary power range
  • Valuelist hardware fault - power supply
  • Min allowable inlet pressure
  • volumetric efficiency
  • valve seat velocity
  • inlet area of the pump
  • Valuelist state of the item
  • failure rate
  • mean repair time
  • standby time
  • valve spill velocity
  • Required net positive inlet pressure
  • active maintenance time
  • time to restoration
  • operating time between failures
  • operating time to failure
  • Valuelist maintenance level
  • maintenance time
  • idle time
  • up time
  • mean downtime
  • repair time
  • operating time
  • mean time to restauration
  • down time
  • external disabled time
  • Valuelist pump kick mode
  • pump kick time
  • Valuelist discrete input value
  • pump kick time difference
  • Valuelist distribution type
  • Valuelist exchange mode
  • exchange time
  • distribution priority
  • Valuelist pump role
  • redundant pump Ids
  • Valuelist operation mode
  • pump collective Ids
  • atmospheric pressure
  • height of the inlet manometer
  • height of the outlet manometer
  • hydraulic efficiency
  • exchange time difference
  • maximum number of pumps in operation
  • Number of Pumps
  • pump rated power input
  • mechanical efficiency
  • pump efficiency
  • pump mechanical power losses
  • overall efficiency
  • maximum dynamic sealing pressure
  • minimum allowable stable flow
  • useful life
  • Valuelist pump operation fault - accessory liquid high
  • Valuelist mechanical fault - unbalance
  • Valuelist mechanical fault - rotor blocked
  • Valuelist mechanical fault - rotor station rubbing
  • Valuelist mechanical fault - misalignment
  • Valuelist mechanical fault - radial bearing abrasion
  • Valuelist pump operation fault - accessory liquid low
  • Valuelist mechanical fault - gap wear
  • Valuelist hardware fault - communication
  • Valuelist pump operation fault - accessory liquid overheat
  • Valuelist pump operation fault - coolant flow
  • Valuelist pump operation fault - coolant high
  • Valuelist pump operation fault - case overheat
  • Valuelist mechanical fault - radial bearing overheat
  • Valuelist pump operation fault - accessory liquid pressure
  • Valuelist pump operation fault - ambient temperature
  • Valuelist pump operation fault - turbine operation
  • Valuelist pump operation fault - under speed
  • Valuelist electronic fault - field circuit
  • Valuelist pump operation fault - torque limit
  • Valuelist pump operation fault - controller overheat
  • Valuelist pump operation fault - converter overheat
  • Valuelist pump operation fault - velocity limit
  • Valuelist pump operation fault - TMS failure
  • Valuelist electronic fault - short circuit
  • Valuelist pump operation fault - wear reserve exhausted
  • Valuelist electronic fault - insulation resistance
  • Valuelist electronic fault - phase failure
  • Valuelist electronic fault - current inside device
  • Valuelist auxiliary device fault - auxiliary medium absence
  • Valuelist auxiliary device fault - actuator element
  • Valuelist auxiliary device fault - ambient temperature
  • Valuelist electronic fault - short to earth
  • Valuelist electronic fault - supply current
  • Valuelist pump operation fault - motor overheat
  • Valuelist pump operation fault - operation fault
  • Valuelist auxiliary device fault - auxiliary medium insufficiency
  • Valuelist electronic fault - installation fault
  • Valuelist electronic fault - supply current high
  • Valuelist electronic fault - supply current low
  • Valuelist pump operation fault - over load
  • Valuelist pump operation fault - over speed
  • Valuelist pump operation fault - temperature fault
  • Valuelist pump operation fault - time out
  • Valuelist pump operation fault - maximum starts at time
  • Valuelist pump operation fault - motor humidity
  • Valuelist pump operation fault - partial load
  • Valuelist pump operation fault - synchronisation
  • inlet temperature of the pump
  • next inspection date
  • Valuelist failure
  • criticality
  • Min allowable outet pressure
  • active preventive maintenance time
  • last servicing date
  • sound power
  • installation date
  • last inspection date
  • next servicing date
  • preventive maintenance time
  • Valuelist electronic fault - supply frequency
  • Valuelist auxiliary device fault - evaluation electronics
  • Valuelist auxiliary device fault - electronic fault
  • Valuelist auxiliary device fault - energy supply
  • Valuelist electronic fault - supply frequency low
  • Valuelist auxiliary device fault - communication error
  • Valuelist electronic fault - supply frequency high
  • Valuelist auxiliary device fault - exciter error
  • severity
  • Valuelist electronic fault - winding temperature
  • corrective maintenance time
  • number of failures
  • Valuelist electronic fault - supply voltage low
  • Valuelist electronic fault - voltage inside device
  • Valuelist electronic fault - supply voltage
  • Valuelist electronic fault - supply voltage high
  • Valuelist process fluid fault - pressure
  • Valuelist mechanical fault - axial bearing abrasion
  • Valuelist process fluid fault - gas
  • Valuelist process fluid fault - liquid
  • Valuelist mechanical fault - bearing fault
  • Valuelist process fluid fault - dry
  • Valuelist mechanical fault - axial bearing fault
  • Valuelist mechanical fault - axial bearing overheat
  • Valuelist process fluid fault - stall
  • Valuelist process fluid fault - temperature
  • Valuelist pump operation fault - accessory liquid flow
  • Valuelist process fluid fault - solid
  • Valuelist process fluid fault - flow
  • Valuelist mechanical fault - brake overheat
  • Valuelist process fluid fault - viscosity
  • Valuelist mechanical fault - brake chopper
  • Valuelist auxiliary device fault - vibration
  • Valuelist auxiliary device fault - wear reserve operation
  • Valuelist auxiliary device fault - start up
  • Valuelist auxiliary device fault - temperature shock
  • Valuelist auxiliary device fault - process influence
  • Valuelist auxiliary device fault - sensor element
  • Valuelist auxiliary device fault - parameter setting
  • Valuelist auxiliary device fault - peripheral
  • Valuelist software fault - application
  • Valuelist auxiliary device fault - wear reserve wear
  • Valuelist software fault - software reset
  • Valuelist process fluid fault - blockage
  • Valuelist software fault - control
  • Valuelist software fault - memory
  • Valuelist software fault - communication
  • Valuelist electronic fault - armature circuit
  • Valuelist pump operation fault - coolant overheat
  • Valuelist pump operation fault - deceleration
  • Valuelist pump operation fault - leakage
  • Valuelist pump operation fault - coolant low
  • Valuelist software fault - OS
  • Valuelist software fault - parameter
  • Valuelist process fluid fault - cavitation
  • Valuelist process fluid fault - condensation
  • Valuelist pump operation fault - lubricant
  • Valuelist pump operation fault - maximum number starts
  • Valuelist mechanical fault - radial bearing fault
  • Valuelist mechanical fault - excess vibration
  • Valuelist pump operation fault - drive overheat
  • Valuelist pump operation fault - generator operation
  • Valuelist pump operation fault - maximum operation time
  • Valuelist pump operation fault - dirty impeller
  • Coolant temperature
  • location
  • day of construction
  • balancing rate of flow
  • net positive suction head required for a drop of 3 %
  • Counterpressure
  • type of product
  • model
  • asset ID
  • manufacturer URI
  • product code
  • device class
  • markings
  • URL
  • software version
  • month of construction
  • initial operation date
  • component name
  • year of construction
  • controller output variable
  • derivative action coefficient
  • hardware version
  • National stock number
  • Valuelist Address of company representative
  • final controlled variable
  • control difference variable
  • controlled variable
  • integral action coefficient
  • dead time
  • piston velocity
  • Pre-charge pressure
  • command variable
  • operating mode
  • proportional action coefficient
  • Stroke volume
  • Valuelist on/off
  • Valuelist property-status
  • geometric displacement volume
  • clearance volume
  • geometrical flow
  • slip flow
  • reference variable
  • total head at inlet area of the installation
  • total head at outlet area of the installation
  • feedback variable
  • manipulated variable
  • axial load of pump rotor
  • number of starts
  • power loss due to internal leakage
  • pump efficiency
  • level
  • lubricating oil consumption
  • mechanical efficiency
  • leakage rate of flow
  • bearing temperature
  • pump temperature
  • axial rotor position
  • pump power output
  • electronic temperature
  • overall efficiency
  • clearance flow
  • radial load of pump rotor
  • Speed
  • fluid temperature
  • sound energy level
  • hydraulic efficiency
  • sound energy
  • housing temperature
  • sound energy
  • sound energy level
  • design radial load
  • declaration of conformity
  • outlet temperature of the pump
  • sound power
  • maximum axial load
  • maximum radial load
  • pump power input curve
  • Valuelist device type
  • possible fluid
  • design axial load
  • pump curve
  • pump efficiency curve
  • sound pressure level
  • max. temperature
  • min. ambient temperature during operation
  • max. air humidity
  • min. temperature
  • Valuelist Controllable
  • Valuelist supported protocol
  • min. air humidity
  • Sound output level
  • Rotational direction of the pump
  • max. ambient temperature
  • Control types
  • Quick-acting speed
  • minimum allowable thermal flow
  • maximum allowable head
  • optimum rate of flow
  • leakage rate of flow
  • minimum allowable head
  • installation NPSH curve
  • net positive suction head required
  • pump NPSH curve
  • Max. nominal frequency
  • motor efficiency
  • Min. nominal frequency
  • Power factor (cos phi)
  • Relief valve counter-pressure
  • Relief valve locking pressure
  • Relief valve overpressure
  • nominal voltage
  • Valuelist energy efficiency class (motor)
  • nominal power consumption
  • enclosure type no/class
  • norminal frequence
  • Nominal speed
  • height of the outlet connection
  • Reference norm of the explosion protection of the electric motor
  • Valuelist conformity declaration present
  • Max. permissible operating temperature at TS1, room2
  • Max. speed of the drive
  • Valuelist Construction form of the coupling
  • minimum density at design temperature
  • Material description of the pumping medium
  • Reference norm of the secondary sealing element material
  • Reference norm of the static seal, housing
  • Material number of the stator
  • normal feed flow
  • Manufacturer order code
  • Product country of origin
  • Min. feed flow
  • Construction form of the transmission
  • Type of set-up
  • Reference norm material of the static seal, housing
  • Nominal speed of the drive
  • Construction form of the electric motor
  • Max. permissible overpressure PS1+ at TS1, room1
  • empty weight
  • Valuelist Construction form of the seal surface, connection, muff A2
  • nominal feed height
  • Valuelist Type of drive
  • Material description of the secondary sealing element
  • Reference norm material of the can
  • Type of the seal
  • Initial breakaway torque of the drive
  • Transmission ratio of the transmission
  • Material number of the bearing neck
  • Material number of the coating, room1
  • Measurement tension of the electric motor
  • Min. permissible operating temperature at TS2, room1
  • code of conformity evaluation
  • Reference norm of the connection, muff A2
  • kinematic viscosity
  • Mass flow
  • Dynamic viscosity
  • differential pressure
  • Installation inlet pressure
  • installation total head
  • net positive suction head
  • Instalation outlet pressure
  • Valuelist nominal pressure (PN) of the flange
  • Nominal size of nozzle/pipe
  • lift circulating pump
  • volumetric efficiency
  • set control mode
  • Valuelist enable
  • set operation mode
  • height of the inlet connection
  • mean rated velocity at inlet
  • total head at inlet area of the pump
  • Valuelist external signal
  • Valuelist multi-phase
  • height of the pump
  • Valuelist actual operation mode
  • Valuelist control inversion
  • Valuelist reverse rotating direction
  • Valuelist actual control mode
  • Valuelist operating mode
  • fluid
  • min. temperature range
  • height of the outlet side of the installation
  • required control mode
  • height of the inlet side of the installation
  • reference plane
  • gas content
  • Useful life
  • minimum ambient temperature (during operation)
  • working temperature
  • maximum ambient temperature (during operation)
  • max. temperature range
  • mean time between failures (MTBF)
  • solids volume fraction
  • Valuelist Field bus system
  • on off cycle
  • Min inlet pressure
  • Valuelist fault action
  • fault value
  • Relief valve set pressure
  • minimum feed height
  • Valuelist discrete output value
  • Max. permissible underpressure PS2- at TS2, room2
  • Valuelist Overflow valve integrated
  • Manufacturer's name of the sealing
  • Valuelist Material number of the static seal, housing
  • Reference norm material of the shaft
  • Valuelist Sealing type
  • Material number of the secondary sealing element
  • Number of the feed elements
  • fabrication number
  • minimum dynamic viscosity at design temperature
  • Explosion protection code of the electric motor
  • material of housing
  • reference standard for material of the housing
  • Construction type conveying element
  • Max. permissible underpressure PS1- at TS1, room2
  • Reference norm material, pumping medium
  • Min. speed of the drive
  • design of dynamic seal
  • Shaft performance for nominal speed, drive
  • Material description of the bearing neck
  • Valuelist Material number of the shaft
  • Construction of the static seal, housing
  • material code of housing
  • Classification system of the transmission
  • drawing number of manufacturer
  • Rotation speed pump
  • Max. feed pressure suction-side
  • description of class
  • Material number of the shaft protective sleeve
  • material code of dynamic seal
  • Valuelist Explosion protection certificate present
  • Length over all, base plate
  • Max. feed flow
  • Material description of the stator
  • Class code of the electric motor
  • Valuelist explosion protection marking
  • Construction type of the connection, muff A1
  • classification system
  • Material number of the pumping medium
  • design
  • Load moment of the drive
  • Material number of the can
  • type of dynamic seal
  • country of manufacturer
  • Min. permissible operating temperature at TS2, room2
  • Reference norm of the coating, room1
  • Measurement performance of the electric motor
  • Filling volume of the equipment
  • Type description of the sealing
  • reference standard
  • Reference norm material of the rotor
  • Operation type time sequence of the drive
  • Reference norm of the bearing neck material
  • Classification system of the electric motor
  • Construction of the connection, muff A2
  • Valuelist guideline for conformity declaration
  • Min. work temperature
  • Reference norm of the connection, muff A1
  • supplier of the identifier
  • Max. permissible underpressure PS1- at TS1, room1
  • Protection type class of the electric motor
  • Thickness of the coating, room1
  • Material description of the shaft protection sleeve
  • Valuelist Nominal pressure of the muffs, A1
  • Valuelist construction size
  • item list number of manufacturer
  • Height over all, base plate
  • Max. permissible overpressure PS2+ at TS2, room1
  • material of dynamic seal
  • Explosion protection device group of the electric motor
  • Material description of the plain bearing bush
  • Max. permissible overpressure PS1+ at TS1, room2
  • overall length
  • Construction of the electric motor
  • Valuelist Nominal width of the muffs, A2
  • Explosion protection temperature class of the electric motor
  • Valuelist Construction form of the seal surface, connection, muff A1
  • Construction type of the connection, muff A2
  • Construction of the transmission
  • Construction of the connection, muff A1
  • Type description
  • Material description of the static seal, housing
  • Valuelist Nominal pressure of the muffs, A2
  • Year of construction
  • width over all, base plate
  • Max. permissible overpressure PS2+ at TS2, room2
  • Moment of inertia of the drive
  • code of class
  • Explosion protection Type of 'e' protection of the electric motor
  • Feed volume per revolution
  • Volume flow of the sealing liquid
  • Max. permissible operating temperature at TS1, room1
  • Class code of the transmission
  • Material number of the drive housing
  • overall width
  • Reference norm of the explosion protection
  • Type of coating application, room 1
  • Max. overpressure of the shaft seal
  • Code of the manufacturer declaration
  • Design temperature
  • Min. feed pressure, suction-side
  • Reference norm protection type of electric motor
  • Reference norm material of the stator
  • Material description of the drive housing
  • Explosion protection category for devices , electric motor
  • Material number of the rotor
  • Setting pressure of the overflow valve
  • Measurement speed of the electric motor
  • Max. feed pressure, suction-side
  • Valuelist Heater/cooler present
  • Reference norm of the plain bearing bush material
  • Valuelist Construction type
  • material code of dynamic seal
  • Material number of the plain bearing bush
  • Reference norm material of the coating, room1
  • Reference norm material of the drive housing
  • maximum rotation speed of the pump
  • Rotational direction of the drive
  • Material description of the rotor
  • reference standard for the dynamic seal
  • Valuelist Nominal width of the muffs, A1
  • maximum density at design temperature
  • Material description of the can
  • Max. permissible pressure differential
  • required supply pressure
  • Torque at nominal speed, drive
  • Material description of the coating, room1
  • Material description of the shaft
  • Supplier product order suffix
  • Supplier product description
  • Supplier product family
  • Max. work temperature
  • Construction form of the housing
  • Valuelist Manufacturer declaration present
  • Max. permissible underpressure PS2- at TS2, room1
  • NPSH-nominal
  • maximum dynamic viscosity at design temperature
  • over all height
  • Reference norm material of the shaft protection sleeve
  • address of additional link
  • Valuelist Use of customs tariff number
  • HS-Code of the WCO
  • Customs tariff number
  • Valuelist Type of customs tariff number
  • GLN of manufacturer
  • URI of manufacturer
  • Brand
  • URI of the product
  • Manufacturer product description
  • Manufacturer product family
  • Manufacturer name
  • Manufacturer product order suffix
  • Manufacturer product designation
  • Manufacturer product root
  • product article number of manufacturer
  • Product type
  • GTIN
  • product article number of supplier
  • name of supplier
  • Supplier product type
  • Supplier product designation
  • GLN of supplier
  • Supplier product root
X

We need your consent

This website uses necessary cookies to ensure the operation of the website. There is no analysis of user behavior by third parties. You can find detailed information about the use of cookies in our privacy policy.