Classification: 51490203 [AGW305003]
Preferred name | 51-49-02-03 Power unit without control system, power class high (hydraulics) |
---|---|
Definition | assembly of a prime mover, pump with or without a reservoir and accessories without control system, prime mover power class > 30 kW |
IRDI | 0173-1#01-AGW305#003 |
|
BASIC Properties: Power unit without control system, power class high (hydraulics)
-
Product type
-
Manufacturer product designation
-
working time (mileage)
-
Manufacturer product root
-
Manufacturer product family
-
Manufacturer product description
-
Manufacturer product order suffix
-
厂商产品编号
-
制造商名称
-
EAN代码
-
Brand
-
URI of the product
-
GLN of manufacturer
-
working time (cycles)
-
storage temperature
-
mechanical power
-
starting torque
-
cracking pressure
-
drive torque
-
assembly torque
-
outlet pressure
-
hydraulic power
-
burst pressure
-
storage time
-
control flow rate
-
overload pressure
-
switching pressure difference
-
closing pressure
-
product life (time)
-
flow rate
-
ambient temperature
-
supply flow rate
-
differential pressure
-
working time (time)
-
remaining working time (cycles)
-
remaining working time (mileage)
-
flow rate amplification
-
flow ripple
-
torque ripple
-
flow rate a-b
-
operating time
-
initial value of the measuring range (flow rate)
-
end value of the measuring range (pressure)
-
fluid temperature
-
total flow rate
-
output torque
-
initial value of the measuring range (pressure)
-
inlet flow rate
-
set pressure
-
remaining operating time (time)
-
remaining working time (time)
-
end value of the measuring range (flow rate)
-
electrical power consumption
-
through drive torque
-
inlet pressure
-
Supplier product order suffix
-
Supplier product family
-
Supplier product type
-
供货商名称
-
GLN of supplier
-
Supplier product designation
-
Supplier product description
-
Supplier product root
-
商品编号
-
Valuelist Type of customs tariff number
-
customs tariff number (TARIC)
-
HS-Code of the WCO
-
Valuelist Use of customs tariff number
-
Customs tariff number
-
address of additional link
-
product identifier
-
certification
-
min. storage temperature
-
specified minimum operating time
-
specified maximum operating time
-
frequency of measurement (operating time)
-
time of measurement (operating time)
-
specified minimum working time (time)
-
minimum set working time (time)
-
time of measurement (working time (time))
-
maximum set switching pressure difference
-
frequency of measurement (working time (time))
-
set switching pressure difference
-
actual operating time
-
time of measurement (switching pressure difference)
-
last operating time
-
frequency of measurement (switching pressure difference)
-
max. storage temperature
-
maximum set operating time
-
actual minimum fluid temperature
-
last fluid temperature
-
set fluid temperature
-
actual maximum fluid temperature
-
minimum set total flow rate
-
minimum set fluid temperature
-
maximum set total flow rate
-
specified minimum fluid temperature
-
maximum set of remaining working time (time)
-
last total flow rate
-
specified maximum remaining working time (time)
-
actual storage time
-
specified minimum remaining working time (time)
-
minimum set operating time
-
specified maximum storage time
-
specified maximum ambient temperature
-
specified minimum ambient temperature
-
last ambient temperature
-
actual ambient temperature
-
actual maximum ambient temperature
-
actual minimum ambient temperature
-
last working time (time)
-
actual working time (time)
-
maximum set working time (time)
-
nominal switching pressure difference
-
specified maximum working time (time)
-
actual switching pressure difference
-
specified maximum fluid temperature
-
minimum set switching pressure difference
-
actual fluid temperature
-
set total flow rate
-
actual total flow rate
-
specified minimum pneumatic power
-
last pneumatic power
-
actual pneumatic power
-
time of measurement (ambient temperature)
-
maximum set control flow rate
-
frequency of measurement (ambient temperature)
-
actual control flow rate
-
minimum set ambient temperature
-
minimum set control flow rate
-
maximum set ambient temperature
-
specified minimum control flow rate
-
set ambient temperature
-
specified maximum control flow rate
-
frequency of measurement (fluid temperature)
-
time of measurement (fluid temperature)
-
specified minimum flow rate
-
specified minimum remaining operating time (time)
-
set control flow rate
-
actual maximum pneumatic power
-
specified minimum total flow rate
-
actual minimum pneumatic power
-
specified maximum total flow rate
-
nominal pneumatic power
-
nominal total flow rate
-
set pneumatic power
-
actual minimum total flow rate
-
maximum set pneumatic power
-
actual maximum total flow rate
-
minimum set pneumatic power
-
actual average total flow rate
-
specified maximum pneumatic power
-
specified maximum flow rate
-
actual maximum electrical power consumption
-
actual minimum electrical power consumption
-
specified maximum switching pressure difference
-
nominal electrical power consumption
-
nominal flow rate
-
set electrical power consumption
-
actual minimum flow rate
-
end value of the measuring range (pressure)
-
actual maximum flow rate
-
specified maximum outlet pressure
-
specified minimum outlet pressure
-
actual outlet pressure
-
nominal outlet pressure
-
specified maximum remaining operating time (time)
-
maximum set of remaining operating time (time)
-
maximum set electrical power consumption
-
load collective
-
specified maximum electrical power consumption
-
actual average flow rate
-
specified minimum electrical power consumption
-
actual flow rate
-
minimum set flow rate
-
last flow rate
-
frequency of measurement (outlet pressure)
-
time of measurement (outlet pressure)
-
actual electrical power consumption
-
last electrical power consumption
-
switching pressure difference
-
specified minimum switching pressure difference
-
end value of the measuring range (flow rate)
-
actual hydraulic power
-
signal feedback
-
maximum set flow rate
-
last hydraulic power
-
set flow rate
-
actual maximum hydraulic power
-
time of measurement (flow rate)
-
actual minimum hydraulic power
-
maximum set fluid temperature
-
frequency of measurement (flow rate)