Search the ECLASS content

ECLASS offers you the opportunity to have a look at and search the latest ECLASS Releases free of charge. The search function is intuitive and allows you to get to know the standard in a quick and non-bureaucratic manner.

How to use the ECLASS search

Please first select ...

  • whether you want to search ECLASS Basic or Advanced
  • in which Release version you want to search
  • in which language you want to search
  • whether you want to search in the classes or for properties, values etc.

Then enter a search term (e.g. "pencil") and click on "Search".
 

Please note that the application of the ECLASS Standard requires a license. (see also ECLASS Terms of Use)

eclass image

Classification: 51410503 [AGW134005]

Preferred name 51-41-05-03 Vane pump, double eccentric, constant (hydraulics)
Definition hydraulic pump in which fluid is displaced via two chambers by a set of radial sliding vanes along a fixed stator
IRDI 0173-1#01-AGW134#005
Already on the watchlist: 0 of max. 4

BASIC Properties: Vane pump, double eccentric, constant (hydraulics)

  • Valuelist Pressure medium
  • max. storage temperature
  • max. dynamic viscosity
  • certification
  • MTTFd
  • min. dynamic viscosity
  • actual minimum mechanical power
  • maximum set inlet flow rate
  • actual maximum mechanical power
  • minimum set inlet flow rate
  • last mechanical power
  • last inlet flow rate
  • minimum set flow rate
  • actual mechanical power
  • specified minimum electrical power consumption
  • last flow rate
  • specified maximum electrical power consumption
  • actual flow rate
  • maximum set electrical power consumption
  • actual average flow rate
  • minimum set hydraulic power
  • actual minimum inlet flow rate
  • actual inlet flow rate
  • min. storage temperature
  • specified minimum hydraulic power
  • actual average inlet flow rate
  • specified maximum hydraulic power
  • actual maximum inlet flow rate
  • specified maximum mechanical power
  • specified maximum control flow rate
  • minimum set mechanical power
  • specified minimum control flow rate
  • maximum set mechanical power
  • frequency of measurement (inlet flow rate)
  • set mechanical power
  • time of measurement (inlet flow rate)
  • nominal mechanical power
  • set inlet flow rate
  • actual product life (time)
  • set pressure difference
  • specified minimum remaining operating time (time)
  • maximum set pressure difference
  • specified maximum remaining operating time (time)
  • minimum set pressure difference
  • maximum set of remaining operating time (time)
  • last pressure difference
  • set electrical power consumption
  • actual maximum flow rate
  • nominal electrical power consumption
  • actual minimum flow rate
  • actual minimum electrical power consumption
  • nominal flow rate
  • actual maximum electrical power consumption
  • specified maximum flow rate
  • maximum set hydraulic power
  • specified maximum inlet flow rate
  • set hydraulic power
  • specified minimum inlet flow rate
  • nominal hydraulic power
  • frequency of measurement (flow rate)
  • actual minimum hydraulic power
  • time of measurement (flow rate)
  • actual maximum hydraulic power
  • set flow rate
  • last hydraulic power
  • maximum set flow rate
  • signal feedback
  • actual hydraulic power
  • specified minimum flow rate
  • load collective
  • specified maximum remaining working time (cycles)
  • specified maximum pressure difference
  • maximum set operating time
  • maximum set of remaining working time (cycles)
  • actual operating time
  • last operating time
  • specified minimum working time (time)
  • time of measurement (working time (time))
  • specified minimum operating time
  • time of measurement (operating time)
  • minimum set operating time
  • specified maximum operating time
  • specified minimum working time (cycles)
  • time of measurement (working time (cycles))
  • maximum set working time (cycles)
  • specified maximum working time (cycles)
  • last electrical power consumption
  • design of the measuring connection
  • specified maximum product life (time)
  • actual electrical power consumption
  • specified minimum remaining working time (mileage)
  • specified minimum pressure difference
  • maximum set of remaining working time (mileage)
  • specified maximum remaining working time (mileage)
  • specified minimum remaining working time (time)
  • actual pressure difference
  • specified maximum remaining working time (time)
  • actual maximum pressure difference
  • maximum set of remaining working time (time)
  • actual minimum pressure difference
  • specified minimum remaining working time (cycles)
  • nominal pressure difference
  • nominal through drive torque
  • specified maximum through drive torque
  • minimum set assembly torque
  • specified minimum working time (mileage)
  • maximum set assembly torque
  • specified maximum working time (mileage)
  • set assembly torque
  • maximum set working time (mileage)
  • specified minimum drive torque
  • nominal assembly torque
  • nominal drive torque
  • specified maximum drive torque
  • time of measurement (ambient temperature)
  • frequency of measurement (ambient temperature)
  • specified maximum starting torque
  • specified minimum starting torque
  • last working time (cycles)
  • actual average assembly torque
  • actual working time (cycles)
  • specified minimum assembly torque
  • specified maximum working time (time)
  • specified maximum assembly torque
  • last working time (time)
  • maximum set working time (time)
  • last working time (mileage)
  • actual working time (time)
  • actual minimum assembly torque
  • actual working time (mileage)
  • last assembly torque
  • actual maximum assembly torque
  • specified minimum through drive torque
  • actual assembly torque
  • specified maximum outlet pressure
  • nominal outlet pressure
  • address of additional link
  • set pressure
  • specified minimum outlet pressure
  • specified minimum set pressure
  • specified maximum set pressure
  • Supplier product order suffix
  • start time of inlet pressure-measurement
  • end time of inlet pressure-measurement
  • Supplier product type
  • time of measurement (inlet pressure)
  • name of supplier
  • frequency of measurement (inlet pressure)
  • Supplier product family
  • maximum set inlet pressure
  • set inlet pressure
  • last inlet pressure
  • Supplier product description
  • minimum set inlet pressure
  • GLN of supplier
  • actual maximum inlet pressure
  • Supplier product designation
  • actual inlet pressure
  • set ambient temperature
  • nominal starting torque
  • actual minimum ambient temperature
  • actual maximum ambient temperature
  • actual ambient temperature
  • last ambient temperature
  • specified minimum ambient temperature
  • specified maximum ambient temperature
  • time of measurement (fluid temperature)
  • frequency of measurement (fluid temperature)
  • minimum set ambient temperature
  • maximum set ambient temperature
  • Valuelist Type of customs tariff number
  • frequency of measurement (outlet pressure)
  • Customs tariff number
  • maximum set fluid temperature
  • HS-Code of the WCO
  • actual outlet pressure
  • Valuelist Use of customs tariff number
  • time of measurement (outlet pressure)
  • GTIN
  • last total flow rate
  • specified minimum flow ripple
  • Manufacturer product description
  • set fluid temperature
  • URI of the product
  • minimum set fluid temperature
  • actual minimum fluid temperature
  • Manufacturer name
  • actual maximum fluid temperature
  • actual fluid temperature
  • last fluid temperature
  • specified maximum fluid temperature
  • set total flow rate
  • maximum set total flow rate
  • Valuelist unit of measure
  • weight per unit of measure
  • specified minimum fluid temperature
  • minimum set control flow rate
  • minimum set total flow rate
  • Supplier product root
  • nominal inlet pressure
  • product article number of supplier
  • actual minimum inlet pressure
  • specified minimum inlet pressure
  • specified maximum inlet pressure
  • Manufacturer product order suffix
  • maximum set flow ripple
  • GLN of manufacturer
  • set flow ripple
  • minimum set working time (time)
  • Manufacturer product root
  • minimum set flow ripple
  • Brand
  • minimum set working time (cycles)
  • Product type
  • last flow ripple
  • minimum set working time (mileage)
  • Manufacturer product designation
  • actual flow ripple
  • Manufacturer product family
  • actual maximum flow ripple
  • actual average flow ripple
  • specified maximum flow ripple
  • product article number of manufacturer
  • actual minimum flow ripple
  • Valuelist Flow direction
  • Valuelist Direction of rotation
  • Grade of filtration
  • Valuelist Type of shaft end
  • Valuelist Position sensing
  • Valuelist Max. admissible degree of contamination of hydraulic fluid (cleanliness class)
  • specified minimum mechanical power
  • actual control flow rate
  • actual average total flow rate
  • actual total flow rate
  • actual minimum total flow rate
  • actual maximum total flow rate
  • Construction series
  • specified maximum total flow rate
  • Size
  • nominal total flow rate
  • Valuelist Pressure transmission medium
  • set control flow rate
  • Valuelist material sealing
  • specified minimum total flow rate
  • hysteresis
  • Valuelist mounting orientation
  • maximum set control flow rate
  • Mounting pattern
  • Valuelist Mounting pattern (standard)
  • Valuelist Actuation type
  • Valuelist Working port (standard)
  • flow rate
  • product life (time)
  • control flow rate
  • ambient temperature
  • flow ripple
  • overload pressure
  • working time (time)
  • differential pressure
  • assembly torque
  • remaining working time (cycles)
  • mechanical power
  • drive torque
  • working time (cycles)
  • storage temperature
  • burst pressure
  • working time (mileage)
  • initial value of the measuring range (pressure)
  • total flow rate
  • initial value of the measuring range (temperature)
  • initial value of the measuring range (flow rate)
  • fluid temperature
  • operating time
  • electrical power consumption
  • end value of the measuring range (pressure)
  • end value of the measuring range (temperature)
  • end value of the measuring range (flow rate)
  • through drive torque
  • inlet pressure
  • inlet flow rate
  • set pressure
  • remaining operating time (time)
  • remaining working time (time)
  • outlet pressure
  • hydraulic power