Classification: 27022201 [AKE148019]

Preferred name 27-02-22-01 High voltage three-phase current asynchronous motor, squirrel-cage rotor (IEC)
Keywords High-voltage motor Three-phase current high-voltage motor (> 6 kV) Three-phase current motor (high-voltage > 6 kV) DS-ASM DS-KL-ASM High-voltage motor (> 6 kV) HS-DS-ASM Motor (high-voltage, > 6 kV) Three-phase current induction motor 6 kV-motor
IRDI 0173-1#01-AKE148#019
Already on the watchlist: 0 of max. 4

BASIC Properties: High voltage three-phase current asynchronous motor, squirrel-cage rotor (IEC)

  • Valuelist Use of customs tariff number
  • Valuelist Type of customs tariff number
  • HS-Code of the WCO
  • Customs tariff number
  • address of additional link
  • Manufacturer name
  • GTIN
  • product article number of manufacturer
  • Brand
  • Manufacturer product description
  • Manufacturer product root
  • Manufacturer product order suffix
  • Manufacturer product designation
  • Manufacturer product family
  • GLN of manufacturer
  • Product type
  • URI of manufacturer
  • URI of the product
  • Valuelist Rated voltage at 60 Hz (reduced)
  • Valuelist Basic construction form
  • Valuelist Rated performance at 50 Hz (reduced)
  • Valuelist Rated performance at 60 Hz (reduced)
  • Valuelist Protection type (reduced)
  • Factor IA/IN
  • Factor MS/MN
  • Factor MA/MN
  • Factor MK/MN
  • Outer diameter / acc. to IEC 60072-1: Dimension P
  • Diameter / acc. to IEC 60072-1: Dimension AC
  • Spacing / acc. to IEC 60072-1: Dimension ED
  • Spacing / acc. to IEC 60072-1: Dimension G
  • Spacing / acc. to IEC 60072-1: Dimension HE
  • Length / acc. to IEC 60072-1: Dimension L1
  • Thickness / acc. to IEC 60072-1: Dimension LA
  • Depth / acc. to IEC 60072-1: Dimension I
  • Diameter / acc. to IEC 60072-1: Dimension S
  • Spacing / acc. to IEC 60072-1: Dimension AS
  • Spacing / acc. to IEC 60072-1: Dimension EA
  • Width / acc. to IEC 60072-1: Dimension F
  • Spacing / acc. to IEC 60072-1: Dimension H'
  • Width / acc. to IEC 60072-1: Dimension FA
  • Diameter / acc. to IEC 60072-1: Dimension DA
  • Width / acc. to IEC 60072-1: Dimension AA
  • Height / acc. to IEC 60072-1: Dimension T
  • Spacing / acc. to IEC 60072-1: Dimension AD
  • Spacing / acc. to IEC 60072-1: Dimension R
  • Spacing / acc. to IEC 60072-1: Dimension GA
  • Total length / acc. to IEC 60072-1: Dimension L
  • Spacing / acc. to IEC 60072-1: Dimension BC
  • Spacing / acc. to IEC 60072-1: Dimension H
  • Thickness / acc. to IEC 60072-1: Dimension HA
  • Total length / acc. to IEC 60072-1: Dimension LM
  • Length / acc. to IEC 60072-1: Dimension AG
  • Spacing / acc. to IEC 60072-1: Dimension Y
  • Spacing / acc. to IEC 60072-1: Dimension BE
  • Length / acc. to IEC 60072-1: Dimension EB
  • Spacing / acc. to IEC 60072-1: Dimension LE
  • Diameter / acc. to IEC 60072-1: dimension AQ
  • Spacing / acc. to IEC 60072-1: Dimension B
  • Width / acc. to IEC 60072-1: Dimension LL
  • Spacing / acc. to non-standard motor: Dimension HB
  • Spacing / acc. to IEC 60072-1: Dimension HH
  • Height / acc. to IEC 60072-1: Dimension GF
  • Total length / acc. to IEC 60072-1: Dimension LC
  • Dimensions / acc. to IEC 60072-1: Dimension BB
  • Spacing / acc. to IEC 60072-1: Dimension GB
  • Spacing / acc. to non-standard motor: dimension HK
  • Diameter / acc. to IEC 60072-1: Dimension D
  • Spacing / acc. to IEC 60072-1: Dimension C
  • Length / acc. to IEC 60072-1: dimension BA
  • Valuelist connection of motor winding
  • Pole number
  • Valuelist Motor type
  • Power loss, static, current-independent [Pls]
  • Valuelist Rotation speed
  • Valuelist Cooling type
  • Valuelist Rated voltage at 50 Hz (reduced)
  • name of supplier
  • Supplier product family
  • Supplier product description
  • Supplier product order suffix
  • Supplier product root
  • GLN of supplier
  • Supplier product type
  • product article number of supplier
  • Supplier product designation
  • Application standards
  • Valuelist certificate/approval
  • Number of mounting holes / acc. to IEC 60072-1: Dimension Z
  • Spacing / acc. to IEC 60072-1: Dimension A
  • Spacing / acc. to IEC 60072-1: Dimension EE
  • Spacing / acc. to IEC 60072-1: Dimension HC
  • Depth / acc. to IEC 60072-1: Dimension GH
  • Spacing / acc. to IEC 60072-1: Dimension AF
  • Spacing / acc. to IEC 60072-1: Dimension LF
  • Spacing / acc. to IEC 60072-1: Dimension GC
  • Height / acc. to IEC 60072-1: Dimension GD
  • Spacing / acc. to IEC 60072-1: Dimension HD
  • Dimensions / acc. to IEC 60072-1: Dimension AB
  • Diameter / acc. to IEC 60072-1: Dimension N
  • Length / acc. to IEC 60072-1: Dimension EC
  • Hole circle diameter / acc. to IEC 60072-1: Dimension M
  • Diameter / acc. to IEC 60072-1: Dimension K
  • Length / acc. to IEC 60072-1: Dimension E
  • Spacing / acc. to IEC 60072-1: dimension CA