Classification: 27022201 [AKE148019]
Preferred name | 27-02-22-01 High voltage three-phase current asynchronous motor, squirrel-cage rotor (IEC) |
---|---|
Keywords | High-voltage motor Three-phase current high-voltage motor (> 6 kV) Three-phase current motor (high-voltage > 6 kV) DS-ASM DS-KL-ASM High-voltage motor (> 6 kV) HS-DS-ASM Motor (high-voltage, > 6 kV) Three-phase current induction motor 6 kV-motor |
IRDI | 0173-1#01-AKE148#019 |
|
BASIC Properties: High voltage three-phase current asynchronous motor, squirrel-cage rotor (IEC)
-
Valuelist Use of customs tariff number
-
Valuelist Type of customs tariff number
-
HS-Code of the WCO
-
Customs tariff number
-
address of additional link
-
Manufacturer name
-
GTIN
-
product article number of manufacturer
-
Brand
-
Manufacturer product description
-
Manufacturer product root
-
Manufacturer product order suffix
-
Manufacturer product designation
-
Manufacturer product family
-
GLN of manufacturer
-
Product type
-
URI of manufacturer
-
URI of the product
-
Valuelist Rated voltage at 60 Hz (reduced)
-
Valuelist Basic construction form
-
Valuelist Rated performance at 50 Hz (reduced)
-
Valuelist Rated performance at 60 Hz (reduced)
-
Valuelist Protection type (reduced)
-
Factor IA/IN
-
Factor MS/MN
-
Factor MA/MN
-
Factor MK/MN
-
Outer diameter / acc. to IEC 60072-1: Dimension P
-
Diameter / acc. to IEC 60072-1: Dimension AC
-
Spacing / acc. to IEC 60072-1: Dimension ED
-
Spacing / acc. to IEC 60072-1: Dimension G
-
Spacing / acc. to IEC 60072-1: Dimension HE
-
Length / acc. to IEC 60072-1: Dimension L1
-
Thickness / acc. to IEC 60072-1: Dimension LA
-
Depth / acc. to IEC 60072-1: Dimension I
-
Diameter / acc. to IEC 60072-1: Dimension S
-
Spacing / acc. to IEC 60072-1: Dimension AS
-
Spacing / acc. to IEC 60072-1: Dimension EA
-
Width / acc. to IEC 60072-1: Dimension F
-
Spacing / acc. to IEC 60072-1: Dimension H'
-
Width / acc. to IEC 60072-1: Dimension FA
-
Diameter / acc. to IEC 60072-1: Dimension DA
-
Width / acc. to IEC 60072-1: Dimension AA
-
Height / acc. to IEC 60072-1: Dimension T
-
Spacing / acc. to IEC 60072-1: Dimension AD
-
Spacing / acc. to IEC 60072-1: Dimension R
-
Spacing / acc. to IEC 60072-1: Dimension GA
-
Total length / acc. to IEC 60072-1: Dimension L
-
Spacing / acc. to IEC 60072-1: Dimension BC
-
Spacing / acc. to IEC 60072-1: Dimension H
-
Thickness / acc. to IEC 60072-1: Dimension HA
-
Total length / acc. to IEC 60072-1: Dimension LM
-
Length / acc. to IEC 60072-1: Dimension AG
-
Spacing / acc. to IEC 60072-1: Dimension Y
-
Spacing / acc. to IEC 60072-1: Dimension BE
-
Length / acc. to IEC 60072-1: Dimension EB
-
Spacing / acc. to IEC 60072-1: Dimension LE
-
Diameter / acc. to IEC 60072-1: dimension AQ
-
Spacing / acc. to IEC 60072-1: Dimension B
-
Width / acc. to IEC 60072-1: Dimension LL
-
Spacing / acc. to non-standard motor: Dimension HB
-
Spacing / acc. to IEC 60072-1: Dimension HH
-
Height / acc. to IEC 60072-1: Dimension GF
-
Total length / acc. to IEC 60072-1: Dimension LC
-
Dimensions / acc. to IEC 60072-1: Dimension BB
-
Spacing / acc. to IEC 60072-1: Dimension GB
-
Spacing / acc. to non-standard motor: dimension HK
-
Diameter / acc. to IEC 60072-1: Dimension D
-
Spacing / acc. to IEC 60072-1: Dimension C
-
Length / acc. to IEC 60072-1: dimension BA
-
Valuelist connection of motor winding
-
Pole number
-
Valuelist Motor type
-
Power loss, static, current-independent [Pls]
-
Valuelist Rotation speed
-
Valuelist Cooling type
-
Valuelist Rated voltage at 50 Hz (reduced)
-
name of supplier
-
Supplier product family
-
Supplier product description
-
Supplier product order suffix
-
Supplier product root
-
GLN of supplier
-
Supplier product type
-
product article number of supplier
-
Supplier product designation
-
Application standards
-
Valuelist certificate/approval
-
Number of mounting holes / acc. to IEC 60072-1: Dimension Z
-
Spacing / acc. to IEC 60072-1: Dimension A
-
Spacing / acc. to IEC 60072-1: Dimension EE
-
Spacing / acc. to IEC 60072-1: Dimension HC
-
Depth / acc. to IEC 60072-1: Dimension GH
-
Spacing / acc. to IEC 60072-1: Dimension AF
-
Spacing / acc. to IEC 60072-1: Dimension LF
-
Spacing / acc. to IEC 60072-1: Dimension GC
-
Height / acc. to IEC 60072-1: Dimension GD
-
Spacing / acc. to IEC 60072-1: Dimension HD
-
Dimensions / acc. to IEC 60072-1: Dimension AB
-
Diameter / acc. to IEC 60072-1: Dimension N
-
Length / acc. to IEC 60072-1: Dimension EC
-
Hole circle diameter / acc. to IEC 60072-1: Dimension M
-
Diameter / acc. to IEC 60072-1: Dimension K
-
Length / acc. to IEC 60072-1: Dimension E
-
Spacing / acc. to IEC 60072-1: dimension CA