Classification: 27131001 [AGG201005]

Preferred name 27-13-10-01 Overcurrent-, feeder- and arc protection
Definition Protective function, for current which exceed the rated value, for feeders with different neutral point type and for arc fault in busbars and encapsulated switchgear systems
IRDI 0173-1#01-AGG201#005
Already on the watchlist: 0 of max. 4

BASIC Properties: Overcurrent-, feeder- and arc protection

  • Valuelist Electrical interface (IEC 60870-5-103, RS 485 with RJ45 connector red.) present
  • Adjustable pick-up value voltage at digital input for threshold values (at DC)
  • Valuelist Operator software for protections function, IEC61850 system configurator present
  • Valuelist Direct. Sens. ground-fault det. for compensated and isolated network (ANSI 67Ns)
  • Selectable national language for SIGRA 4-software
  • Required operating system for SIGRA 4-software
  • Selectable national language for IEC 61850 system configurator software
  • Required operating system for IEC 61850 system configurator software
  • Type of cabling of arc detector
  • Product variations
  • Selectable national language for DIGSI-software
  • Required operating system for DIGSI-software
  • Power factor
  • Number of arc detector
  • Frame size of enclosure
  • Wire length to the arc detector
  • Number of low level signal-voltage transformer inputs
  • Number of low level signal-current transformer inputs
  • Number of sensor inputs for arc detector
  • max. number of LEDs
  • max. number of internal RTD-inputs
  • Valuelist max. number of digital outputs, inclusive signaling contact
  • max. number of voltage inputs
  • max. number of current inputs
  • Number of events
  • Valuelist Licence for DIGSI 4 Professional + IEC 61850 system configurator present
  • max. number of digital inputs
  • Number of parameter sets
  • Valuelist Operator software for protections function, SIGRA 4 present
  • Valuelist IRIG-B input present
  • Valuelist Licence for DIGSI 4 Professional present
  • Valuelist Licence for DIGSI 4 Basis present
  • Valuelist Protocol is supported (IEC 61850)
  • Valuelist Electrical interface (DNP 3 TCP, 100 Mbit/s, LC port) present
  • Valuelist Logic editor present
  • Valuelist Extended measured value acquisition present
  • Valuelist Protocol is supported (DNP3)
  • Valuelist Supports protocol for PROFINET I0
  • Valuelist Electrical interface (DNP 3 TCP, 100 Mbit/s, double RJ45 connector) present
  • Valuelist Electrical interface (DNP 3 serial, RS 485 with RJ45 connector) present
  • Valuelist Protocol is supported (PROFIBUS DP slave)
  • Valuelist Protocol is supported (IEC 60870-5-104)
  • Valuelist Protocol is supported (Modbus RTU-slave)
  • Valuelist Protocol is supported (Modbus TCP/IP)
  • Valuelist Measuring-voltage failure detection (ANSI 60FL) present
  • Valuelist Type of time synchronization of transmitter, minutes-pulse present
  • Valuelist Electrical interface (IEC 60870-5-103, RS 232) present
  • Valuelist Service interface (Reydisp at USB) present
  • Valuelist Protocol is supported (DHCP)
  • Valuelist Protocol is supported (HSR)
  • Valuelist Protocol is supported (SNTP)
  • Valuelist time synchronization present
  • Valuelist Software interface (DIGSI for Ethernet with RJ45 connector) present
  • Valuelist Software interface (DIGSI with RS 232) present
  • Valuelist Protocol is supported (PRP)
  • Valuelist Protocol is supported (RSTP)
  • Valuelist Electrical interface (IEC 61850, 100 Mbit/s, double RJ45 connector) present
  • Valuelist Electrical interface (DNP 3 serial, RS 485 with sub-D connection) present
  • Valuelist Protocol is supported (IEC 61850-9-2)
  • Valuelist Optical interface (IEC 61850, 100 Mbit/s, 1300 nm double LC port) present
  • Valuelist Electrical interface (PROFINET IO, 100 Mbit/s, double RJ45 connector) present
  • Valuelist Electrical interface (Modbus RTU-slave, RS 485 with sub-D connection) present
  • Valuelist Electrical interface (DNP 3 serial, RS 485 with terminal connection) present
  • Valuelist Optical interface (PROFINET IO, 100 Mbit/s, double LC port) present
  • Valuelist Electrical interface (PROFIBUS DP slave, RS 485 with sub-D connection) present
  • Valuelist Electrical interface (PROFIBUS DP slave) present
  • Valuelist Electrical interface (Modbus RTU-slave, RS 485 with terminal connection) present
  • Valuelist Electrical interface (Modbus TCP, 100 Mbit/s, double RJ45) present
  • Valuelist Electrical interface (IEC 60870-5-103, RS 485 with sub-D connection) present
  • Valuelist Electrical interface (IEC 60870-5-103, RS 485 with terminal connection) present
  • Valuelist Electrical interface (IEC 60870-5-104) present
  • Valuelist Optical interface (IEC 60870-5-103, 820 nm with ST(BFOC)) present
  • Valuelist Service interface present
  • Valuelist Pluggable terminal blocks present
  • Valuelist Operator software for protections function, DIGSI present
  • Valuelist Service interface (DIGSI at USB-A port) present
  • Valuelist Changeover of setting group present
  • Valuelist Monitoring present
  • Valuelist Keyswitch present
  • Valuelist IO modules expandable
  • Valuelist Control present
  • Valuelist External trip initiation present
  • Valuelist Sequence-of-events recorder present
  • Valuelist Fault recording analog and digital signals present
  • Valuelist Quicklogic present
  • Valuelist Graphical Logic present
  • Valuelist Inrush detection present
  • Valuelist National language user adjustable (Western European character set)
  • Valuelist CFC standard present
  • Valuelist Circuit breaker monitoring present
  • Valuelist Operating sequences for control applications present
  • Valuelist CFC arthmetic present
  • Valuelist Type of measured value acquisition of operational measured values, standard
  • Valuelist Load Blinder (ANSI 21LB) present
  • Valuelist Switching statistic present
  • Valuelist Type of measured value acquisition, extended, min./max.-values, average values
  • Valuelist Differential protection (ANSI 87) present
  • Valuelist Lockout (ANSI 86) present
  • Valuelist Fault locator (ANSI FL) present
  • Valuelist High-impedance restricted ground-fault protection (ANSI 87N) present
  • Valuelist Frequency protection (ANSI 81) present
  • Valuelist automatically reclosing (ANSI 79) present
  • Valuelist Signal transmission method (ANSI 85) present
  • Valuelist Rate-of-frequency-change protection (ANSI 81R) present
  • Valuelist Directional time-overcurrent protection for ground-faults (ANSI 67N)
  • Valuelist Directional time-overcurrent protection, phase, phases (ANSI 67) present
  • Valuelist Trip-circuit supervision (ANSI 74TC) present
  • Valuelist Power-swing blocking (ANSI 68) present
  • Valuelist Rate-of-voltage-change protection (ANSI 59R/27R) present
  • Valuelist Overvoltage protection-Zero-sequence system (ANSI 59N) present
  • Valuelist Resetting interlock (ANSI 66) present
  • Valuelist Ground-fault protection (machine) (ANSI 64) present
  • Valuelist Voltage dependent overcurrent protection (ANSI 51V) present
  • Valuelist Cold loag pickup (ANSI 51C) present
  • Valuelist Overvoltage protection (ANSI 59) present
  • Valuelist power factor (ANSI 55) present
  • Valuelist Intermittent ground-fault protection (ANSI 50Ns) present
  • Valuelist Sensitive ground-current protection (ANSI 50Ns) present
  • Valuelist Inverse time-overcurrent protection (ANSI 51/51N) present
  • Valuelist Circuit-breaker failure protection (ANSI 50BF) present
  • Valuelist Definite time-overcurrent protection (ANSI 50/50N) present
  • Valuelist Thermal overload protection (ANSI 49) present
  • Valuelist Arc-protection (ANSI AFD) present
  • Valuelist Instantaneous tripping (ANSI SOTF) present
  • Valuelist Overcurrent protection-Negative-sequence system (ANSI 46) present
  • Valuelist Unbalanced load protection (ANSI 46) present
  • Valuelist Overvoltage protection-Negative-sequence system (ANSI 47) present
  • Valuelist Supervision of phase rotation (ANSI 47) present
  • Valuelist Undervoltage protection (ANSI 27) present
  • Valuelist Synchronising Check (ANSI 25) present
  • Valuelist Undercurrent protection (ANSI 37) present
  • Valuelist Directional power supervision (ANSI 32) present
  • Valuelist Voltage type
  • width
  • Valuelist 3-pole tripping present
  • Valuelist Suitable for overcurrent protection
  • depth
  • max. supply voltage
  • Valuelist Display type
  • height
  • min. supply voltage with DC
  • Max. operating temperature
  • min. supply voltage
  • max. supply voltage with DC
  • HS-Code of the WCO
  • Valuelist Use of customs tariff number
  • Min. operating temperature
  • Number of function keys
  • Valuelist Type of customs tariff number
  • Customs tariff number
  • URI of manufacturer
  • address of additional link
  • Brand
  • GLN of manufacturer
  • URI of the product
  • Manufacturer product family
  • Manufacturer name
  • product article number of manufacturer
  • Manufacturer product description
  • Manufacturer product root
  • Manufacturer product designation
  • GTIN
  • Product type
  • GLN of supplier
  • Manufacturer product order suffix
  • product article number of supplier
  • Supplier product designation
  • Supplier product root
  • name of supplier
  • Supplier product description
  • Supplier product type
  • Supplier product order suffix
  • Supplier product family
X

We need your consent

This website uses necessary cookies to ensure the operation of the website. There is no analysis of user behavior by third parties. You can find detailed information about the use of cookies in our privacy policy.