Search the ECLASS content

ECLASS offers you the opportunity to have a look at and search the latest ECLASS Releases free of charge. The search function is intuitive and allows you to get to know the standard in a quick and non-bureaucratic manner.

How to use the ECLASS search

Please first select ...

  • whether you want to search ECLASS Basic or Advanced
  • in which Release version you want to search
  • in which language you want to search
  • whether you want to search in the classes or for properties, values etc.

Then enter a search term (e.g. "pencil") and click on "Search".
 

Please note that the application of the ECLASS Standard requires a license. (see also ECLASS Terms of Use)

eclass image

Classification: 27131003 [AGG203005]

Preferred name 27-13-10-03 Distance protection
Definition Protective function of open-wire lines and wires in all voltage levels between 5 and 765 kV. The calculation of impedance is the criterion of an error
IRDI 0173-1#01-AGG203#005
Already on the watchlist: 0 of max. 4

BASIC Properties: Distance protection

  • Valuelist Measuring-voltage failure detection (ANSI 60FL) present
  • Number of events
  • Valuelist Monitoring present
  • Number of parameter sets
  • Valuelist External trip initiation present
  • Valuelist Control present
  • Valuelist Fault recording analog and digital signals present
  • Valuelist Sequence-of-events recorder present
  • Valuelist Extended measured value acquisition present
  • Valuelist Logic editor present
  • Product variations
  • Valuelist IRIG-B input present
  • Valuelist Changeover of setting group present
  • max. number of digital inputs
  • max. number of current inputs
  • max. number of voltage inputs
  • Selectable national language for SIGRA 4-software
  • Required operating system for IEC 61850 system configurator software
  • Selectable national language for IEC 61850 system configurator software
  • Valuelist Licence for DIGSI 4 Basis present
  • Valuelist Operator software for protections function, DIGSI present
  • Required operating system for DIGSI-software
  • Selectable national language for DIGSI-software
  • Valuelist Operator software for protections function, SIGRA 4 present
  • Valuelist Licence for DIGSI 4 Professional present
  • Valuelist Licence for DIGSI 4 Professional + IEC 61850 system configurator present
  • Required operating system for SIGRA 4-software
  • Valuelist Operator software for protections function, IEC61850 system configurator present
  • Supplier product order suffix
  • Supplier product description
  • name of supplier
  • Supplier product type
  • Supplier product family
  • Supplier product designation
  • GLN of supplier
  • product article number of supplier
  • Supplier product root
  • GTIN
  • product article number of manufacturer
  • Manufacturer product order suffix
  • Manufacturer product designation
  • Manufacturer product root
  • Product type
  • Brand
  • URI of the product
  • Manufacturer product description
  • Manufacturer product family
  • Manufacturer name
  • GLN of manufacturer
  • URI of manufacturer
  • address of additional link
  • Customs tariff number
  • height
  • depth
  • Valuelist Suitable for Distance protection
  • Valuelist 3-pole tripping present
  • Valuelist Type of customs tariff number
  • Valuelist Use of customs tariff number
  • HS-Code of the WCO
  • width
  • Valuelist Frequency protection (ANSI 81) present
  • Valuelist Rate-of-frequency-change protection (ANSI 81R) present
  • Valuelist Lockout (ANSI 86) present
  • Valuelist Type of measured value acquisition of operational measured values, standard
  • Valuelist Overvoltage protection (ANSI 59) present
  • Valuelist Overvoltage protection-Zero-sequence system (ANSI 59N) present
  • Valuelist Power-swing blocking (ANSI 68) present
  • Valuelist Trip-circuit supervision (ANSI 74TC) present
  • Valuelist Operating sequences for control applications present
  • Valuelist Graphical Logic present
  • Valuelist Quicklogic present
  • Valuelist Inrush detection present
  • Valuelist Type of measured value acquisition, extended, min./max.-values, average values
  • Valuelist Switching statistic present
  • Valuelist CFC standard present
  • Valuelist CFC arthmetic present