Classification: 27131005 [AGG205004]

Preferred name 27-13-10-05 Breaker management
Definition Protective function for automatic reclosing, synchronising check and circuit breaker failure protection, which goes into action at 1- and 3-pole reclosings of a circuit breaker, after release of this switch due to an error
IRDI 0173-1#01-AGG205#004
Already on the watchlist: 0 of max. 4

BASIC Properties: Breaker management

  • Valuelist Undervoltage protection (ANSI 27) present
  • Valuelist Thermal overload protection (ANSI 49) present
  • Valuelist Definite time-overcurrent protection (ANSI 50/50N) present
  • Valuelist Instantaneous tripping (ANSI SOTF) present
  • Customs tariff number
  • width
  • height
  • depth
  • Valuelist Trip-circuit supervision (ANSI 74TC) present
  • Valuelist Frequency protection (ANSI 81) present
  • Valuelist Rate-of-frequency-change protection (ANSI 81R) present
  • Valuelist Lockout (ANSI 86) present
  • Valuelist Arc-protection (ANSI AFD) present
  • Valuelist Circuit-breaker failure protection (ANSI 50BF) present
  • Valuelist Overvoltage protection (ANSI 59) present
  • Valuelist Overvoltage protection-Zero-sequence system (ANSI 59N) present
  • Valuelist CFC arthmetic present
  • Valuelist Operating sequences for control applications present
  • Valuelist Graphical Logic present
  • Valuelist Quicklogic present
  • Valuelist Type of measured value acquisition of operational measured values, standard
  • Valuelist Type of measured value acquisition, extended, min./max.-values, average values
  • Valuelist Switching statistic present
  • Valuelist CFC standard present
  • Valuelist Sequence-of-events recorder present
  • Valuelist Monitoring present
  • Valuelist Measuring-voltage failure detection (ANSI 60FL) present
  • Number of events
  • Valuelist Inrush detection present
  • Valuelist External trip initiation present
  • Valuelist Control present
  • Valuelist Fault recording analog and digital signals present
  • Number of sensor inputs for arc detector
  • Number of arc detector
  • Type of cabling of arc detector
  • Wire length to the arc detector
  • Number of parameter sets
  • Valuelist Changeover of setting group present
  • Valuelist Extended measured value acquisition present
  • Valuelist Logic editor present
  • Product variations
  • Supplier product family
  • Supplier product order suffix
  • Supplier product description
  • Supplier product root
  • Supplier product designation
  • GLN of supplier
  • name of supplier
  • Supplier product type
  • product article number of supplier
  • Manufacturer product root
  • Product type
  • GTIN
  • product article number of manufacturer
  • Manufacturer product order suffix
  • Manufacturer product designation
  • Manufacturer product family
  • Manufacturer name
  • Manufacturer product description
  • product identifier
  • address of additional link
  • Brand
  • URI of the product
  • GLN of manufacturer
  • URI of manufacturer
  • customs tariff number (TARIC)
  • Valuelist Type of customs tariff number
  • Valuelist Use of customs tariff number
  • HS-Code of the WCO
X

We need your consent

This website uses necessary cookies to ensure the operation of the website. There is no analysis of user behavior by third parties. You can find detailed information about the use of cookies in our privacy policy.