Classification: 27131009 [AGG209005]

Preferred name 27-13-10-09 Motor protection (multifunctional protection)
Definition Protective function, which prevents engines from overload and short ( Protection of the winding insulation against inadmissible heating)
IRDI 0173-1#01-AGG209#005
Already on the watchlist: 0 of max. 4

BASIC Properties: Motor protection (multifunctional protection)

  • Supplier product family
  • Supplier product order suffix
  • Supplier product description
  • name of supplier
  • Supplier product type
  • product article number of supplier
  • Supplier product root
  • Supplier product designation
  • GLN of supplier
  • Manufacturer product order suffix
  • Manufacturer product designation
  • Manufacturer product root
  • Product type
  • GTIN
  • product article number of manufacturer
  • Manufacturer product description
  • Manufacturer product family
  • Manufacturer name
  • Brand
  • URI of the product
  • GLN of manufacturer
  • URI of manufacturer
  • address of additional link
  • Required operating system for IEC 61850 system configurator software
  • Selectable national language for DIGSI-software
  • Selectable national language for SIGRA 4-software
  • Selectable national language for IEC 61850 system configurator software
  • Valuelist IRIG-B input present
  • Product variations
  • Number of arc detector
  • Wire length to the arc detector
  • Type of cabling of arc detector
  • Valuelist Logic editor present
  • Valuelist forward-power protection (ANSI 32F) present
  • Valuelist reverse-power protection (ANSI 32R) present
  • Valuelist Type of time synchronization of transmitter, minutes-pulse present
  • Valuelist time synchronization present
  • Valuelist Extended measured value acquisition present
  • Valuelist Opt. interface (Modbus RTU-slave, 820 nm with ST(BFOC) opt. connector) present
  • Valuelist Direct. Sens. ground-fault det. for compensated and isolated network (ANSI 67Ns)
  • Valuelist Type of measured value acquisition of operational measured values, standard
  • Valuelist Type of measured value acquisition, extended, min./max.-values, average values
  • Valuelist Switching statistic present
  • Valuelist Circuit breaker monitoring present
  • Valuelist CFC standard present
  • Valuelist CFC arthmetic present
  • Valuelist Operating sequences for control applications present
  • Valuelist Graphical Logic present
  • Valuelist Quicklogic present
  • Valuelist National language user adjustable (Western European character set)
  • Valuelist Inrush detection present
  • Valuelist External trip initiation present
  • Valuelist Control present
  • Valuelist Fault recording analog and digital signals present
  • Valuelist Sequence-of-events recorder present
  • Valuelist Measuring-voltage failure detection (ANSI 60FL) present
  • Valuelist Protection function at blocked rotor (ANSI 14) present
  • Valuelist temperature monitoring (ANSI 38) present
  • Valuelist Starting-time supervision (ANSI 48) present
  • Valuelist Load-jam protection (ANSI 50L) present
  • Power factor
  • Valuelist Monitoring present
  • Valuelist Changeover of setting group present
  • Valuelist IO modules expandable
  • Number of events
  • Number of parameter sets
  • max. number of digital inputs
  • Valuelist max. number of digital outputs, inclusive signaling contact
  • max. number of internal RTD-inputs
  • max. number of current inputs
  • max. number of voltage inputs
  • Number of low level signal-current transformer inputs
  • Number of low level signal-voltage transformer inputs
  • max. number of LEDs
  • Frame size of enclosure
  • Valuelist LED, multi-colored present
  • Valuelist Pluggable terminal blocks present
  • Valuelist Service interface present
  • Valuelist Service interface (DIGSI at USB-A port) present
  • Valuelist Service interface (Reydisp at USB) present
  • Valuelist Operator software for protections function, DIGSI present
  • Valuelist Operator software for protections function, SIGRA 4 present
  • Valuelist Operator software for protections function, IEC61850 system configurator present
  • Valuelist Electrical interface (IEC 60870-5-103, RS 485 with terminal connection) present
  • Valuelist Electrical interface (PROFIBUS DP slave) present
  • Valuelist Electrical interface (PROFIBUS DP slave, RS 485 with sub-D connection) present
  • Valuelist Electrical interface (Modbus RTU-slave, RS 485 with terminal connection) present
  • Valuelist Electrical interface (Modbus RTU-slave, RS 485 with sub-D connection) present
  • Valuelist Electrical interface (PROFINET IO, 100 Mbit/s, double RJ45 connector) present
  • Valuelist Electrical interface (DNP 3 serial, RS 485 with terminal connection) present
  • Valuelist Electrical interface (DNP 3 serial, RS 485 with sub-D connection) present
  • Valuelist Electrical interface (IEC 61850, 100 Mbit/s, double RJ45 connector) present
  • Valuelist Electrical interface (DNP 3 TCP, 100 Mbit/s, double RJ45 connector) present
  • Valuelist Electrical interface (DNP 3 TCP, 100 Mbit/s, LC port) present
  • Valuelist Protocol is supported (IEC 61850-9-2)
  • Valuelist Protocol is supported (RSTP)
  • Valuelist Protocol is supported (PRP)
  • Valuelist Protocol is supported (HSR)
  • Valuelist Protocol is supported (IEC 61850)
  • Valuelist Licence for DIGSI 4 Basis present
  • Valuelist Licence for DIGSI 4 Professional present
  • Valuelist Licence for DIGSI 4 Professional + IEC 61850 system configurator present
  • Required operating system for DIGSI-software
  • Required operating system for SIGRA 4-software
  • Customs tariff number
  • Valuelist Type of customs tariff number
  • Valuelist Use of customs tariff number
  • HS-Code of the WCO
  • Valuelist Display type
  • Number of function keys
  • max. supply voltage
  • max. supply voltage with DC
  • min. supply voltage
  • min. supply voltage with DC
  • Valuelist Voltage type
  • Max. operating temperature
  • Min. operating temperature
  • width
  • height
  • depth
  • Valuelist Suitable for motor protection
  • Valuelist 3-pole tripping present
  • Valuelist Undervoltage protection (ANSI 27) present
  • Valuelist Directional power supervision (ANSI 32) present
  • Valuelist Undercurrent protection (ANSI 37) present
  • Valuelist Unbalanced load protection (ANSI 46) present
  • Valuelist Overcurrent protection-Negative-sequence system (ANSI 46) present
  • Valuelist Supervision of phase rotation (ANSI 47) present
  • Valuelist Overvoltage protection-Negative-sequence system (ANSI 47) present
  • Valuelist Thermal overload protection (ANSI 49) present
  • Valuelist Definite time-overcurrent protection (ANSI 50/50N) present
  • Valuelist Instantaneous tripping (ANSI SOTF) present
  • Valuelist Sensitive ground-current protection (ANSI 50Ns) present
  • Valuelist Intermittent ground-fault protection (ANSI 50Ns) present
  • Valuelist Circuit-breaker failure protection (ANSI 50BF) present
  • Valuelist Inverse time-overcurrent protection (ANSI 51/51N) present
  • Valuelist Cold loag pickup (ANSI 51C) present
  • Valuelist Voltage dependent overcurrent protection (ANSI 51V) present
  • Valuelist power factor (ANSI 55) present
  • Valuelist Overvoltage protection (ANSI 59) present
  • Valuelist Overvoltage protection-Zero-sequence system (ANSI 59N) present
  • Valuelist Rate-of-voltage-change protection (ANSI 59R/27R) present
  • Valuelist Ground-fault protection (machine) (ANSI 64) present
  • Valuelist Resetting interlock (ANSI 66) present
  • Valuelist Directional time-overcurrent protection, phase, phases (ANSI 67) present
  • Valuelist Directional time-overcurrent protection for ground-faults (ANSI 67N)
  • Valuelist Trip-circuit supervision (ANSI 74TC) present
  • Valuelist Frequency protection (ANSI 81) present
  • Valuelist Rate-of-frequency-change protection (ANSI 81R) present
  • Valuelist Lockout (ANSI 86) present
  • Valuelist High-impedance restricted ground-fault protection (ANSI 87N) present
  • Valuelist Load Blinder (ANSI 21LB) present