Classification: 27171202 [AHE430002]
Preferred name | 27-17-12-02 Surge arrester power engineering AC (type 2) |
---|---|
Definition | Devices for discharging surge currents coupled either directly (galvanically) or indirectly (inductively) into the AC power part of the electrical installation |
Keywords | Lightning protection External lightning protection |
IRDI | 0173-1#01-AHE430#002 |
|
BASIC Properties: Surge arrester power engineering AC (type 2)
-
Supplier product designation
-
name of supplier
-
GLN of supplier
-
product article number of supplier
-
Supplier product order suffix
-
Supplier product type
-
Supplier product family
-
Supplier product description
-
Supplier product root
-
Valuelist test standard
-
max. current of remote indication (DC)
-
Valuelist nominal voltage (for AC)
-
residual current AC
-
min. cross-section of the remote indication (flexible)
-
Valuelist protective element pluggable
-
max. cross-section of the remote indication (rigid)
-
Valuelist TOV - behaviour (200 ms)
-
Valuelist TOV - behaviour (120 min)
-
Valuelist SPD failure mode
-
Valuelist no leakage current
-
max. cross-section of the remote indication (flexible)
-
max. current of remote indication (AC)
-
transition surge current rating
-
max. overcurrent protective device (V-type wiring)
-
max. voltage of remote indication (DC)
-
Valuelist connection method of the remote indication
-
max. allowed elevation above mean sea level
-
Valuelist Approval certificates
-
depth of packing
-
Valuelist Assembly type
-
Contents per packing unit
-
max. continuous operating voltage AC
-
short-circuit breaking capacity
-
Valuelist suitable for outdoor use
-
minimum ambient temperature (during operation)
-
voltage protection level (L-PE/N-PE)
-
Max. nominal frequency
-
min. relative humidity (operation)
-
voltage protection level (L-N)
-
width of packing
-
Insulation stripped length
-
max. voltage of remote indication (AC)
-
distance to grounded or conductive parts
-
max. overcurrent protective device (branch wiring)
-
Integrated overcurrent protective device selective to fuse
-
nominal discharge current (8/20) µs (L-PE(N))
-
min. cross-section of the remote indication (rigid)
-
Valuelist type of remote indication contact
-
Valuelist characteristic of backup fuse
-
max. discharge current (8/20) µs (L-N)
-
max. discharge current (8/20) µs (L-PE(N))
-
Valuelist SPD type (IEC 61643)
-
max. discharge current (8/20) µs (N-PE)
-
Valuelist number of ports
-
nominal discharge current (8/20) µs (N-PE)
-
Valuelist remote indication integrated
-
Valuelist configuration of SPD
-
Net weight
-
Valuelist type of electrical terminal
-
Valuelist type of certificate
-
max. relative humidity (operation)
-
voltage protection level (N-PE)
-
Valuelist Degree of protection (IP), mounted
-
width
-
nominal discharge current (8/20) µs (L-N)
-
Valuelist Integrated overcurrent protective device
-
Valuelist flammability rating of the insulating material (based on UL 94)
-
length of packing
-
follow current extinguishing capability
-
gross weight
-
Min. nominal frequency
-
Valuelist system configuration
-
height
-
maximum ambient temperature (during operation)
-
depth
-
Valuelist fault indication at device
-
min. connectable conductor cross-section multiple wire
-
Valuelist width in units of measurement
-
Max. line cross section, rigid
-
Min. line cross section, rigid
-
max. connectable conductor cross-section multiple wire
-
min. temperature during operation, °F (UL 1449)
-
max. temperature during operation, °F (UL 1449)
-
Valuelist edition of UL 1449 used for testing
-
Valuelist type of load, alarm circuit (UL1449)
-
Valuelist mode of protection AC (UL 1449)
-
Valuelist service configuration (UL 1449)
-
Valuelist number of ports (UL 1449)
-
Valuelist degree of protection (IP) (UL1449)
-
Valuelist type of listing (UL 1449)
-
operating voltage, alarm circuit AC (UL 1449)
-
fuse [option 2], current rating (UL 1449)
-
Valuelist SPD Type (UL 1449)
-
fuse [option 2], voltage (UL 1449)
-
fuse [option 1], class
-
fuse [option 1], current rating (UL 1449)
-
fuse [option 2], class
-
Valuelist min. wire cross-section, alarm circuit (UL 1449)
-
fuse [option 1], voltage (UL 1449)
-
min. humidity during operation (UL 1449)
-
max. humidity during operation (UL 1449)
-
Valuelist mounting method (UL 1449)
-
max. allowed elevation above mean sea level, ft (UL 1449)
-
surge current capacity per phase (UL 1449)
-
max. allowed elevation above mean sea level, m (UL 1449)
-
min. temperature during operation, °C (UL 1449)
-
max. continuous operating voltage AC (L-G)
-
max. temperature during operation, °C (UL 1449)
-
nominal discharge current (UL 1449)
-
operating voltage, alarm circuit DC (UL 1449)
-
Valuelist operating voltage AC (UL 1449)
-
nominal load current, alarm circuit AC (UL1449)
-
nominal load current, alarm circuit DC (UL 1449)
-
Valuelist UL Category Code number (UL 1449)
-
AC frequency, alarm circuit (UL 1449)
-
Valuelist internal disconnect feature (UL 1449)
-
voltage protection rating (L-L) (UL 1449)
-
voltage protection rating (N-G) (UL 1449)
-
min. torque, alarm circuit (UL 1449)
-
min. torque (UL 1449)
-
max. torque (UL 1449)
-
short-circuit current rating acc. to UL 1449
-
load current rating AC (UL 1449)
-
max. continuous operating voltage AC (N-G)
-
voltage protection rating (L-N) (UL 1449)
-
max. continuous operating voltage AC (L-N)
-
voltage protection rating (L-G) (UL 1449)
-
Valuelist min. wire cross-section (UL 1449)
-
max. continuous operating voltage AC (L-L)
-
Valuelist max. wire cross-section, alarm circuit (UL 1449)
-
measured limiting voltage (L-L) (UL 1449)
-
AC power frequency
-
measured limiting voltage (N-G) (UL 1449)
-
Valuelist max. wire cross-section (UL 1449)
-
measured limiting voltage (L-G) (UL 1449)
-
max. torque, alarm circuit (UL 1449)
-
measured limiting voltage (L-N) (UL 1449)
-
Manufacturer product root
-
Manufacturer product family
-
Manufacturer product description
-
Manufacturer product order suffix
-
product article number of manufacturer
-
Manufacturer name
-
GTIN
-
Brand
-
Product type
-
GLN of manufacturer
-
Manufacturer product designation
-
address of additional link
-
Customs tariff number