Classification: 27171204 [AHE432002]

Preferred name 27-17-12-04 Combination arrester power engineering AC (type 1+2)
Definition devices for lightning equipotential bonding between the external lightning protection system and the AC power part of the electrical installation, capable of dissipating both lightning currents and surge currents
Keywords Lightning protection External lightning protection
IRDI 0173-1#01-AHE432#002
Already on the watchlist: 0 of max. 4

BASIC Properties: Combination arrester power engineering AC (type 1+2)

  • width of packing
  • Insulation stripped length
  • min. relative humidity (operation)
  • voltage protection level (L-N)
  • voltage protection level (L-PE/N-PE)
  • Max. nominal frequency
  • Valuelist suitable for outdoor use
  • minimum ambient temperature (during operation)
  • Valuelist flammability rating of the insulating material (based on UL 94)
  • length of packing
  • nominal discharge current (8/20) µs (L-N)
  • Valuelist Integrated overcurrent protective device
  • Valuelist Degree of protection (IP), mounted
  • width
  • max. relative humidity (operation)
  • voltage protection level (N-PE)
  • depth
  • Valuelist fault indication at device
  • height
  • maximum ambient temperature (during operation)
  • Min. nominal frequency
  • Valuelist system configuration
  • follow current extinguishing capability
  • gross weight
  • Valuelist type of certificate
  • Net weight
  • Valuelist type of electrical terminal
  • Supplier product family
  • Supplier product description
  • Supplier product order suffix
  • Supplier product type
  • product article number of supplier
  • name of supplier
  • GLN of supplier
  • Supplier product root
  • Supplier product designation
  • Manufacturer product root
  • Manufacturer product family
  • Brand
  • Manufacturer name
  • GTIN
  • product article number of manufacturer
  • Manufacturer product description
  • Manufacturer product order suffix
  • Manufacturer product designation
  • Product type
  • GLN of manufacturer
  • address of additional link
  • Customs tariff number
  • max. connectable conductor cross-section multiple wire
  • Max. line cross section, rigid
  • min. connectable conductor cross-section multiple wire
  • Valuelist width in units of measurement
  • Min. line cross section, rigid
  • max. overcurrent protective device (branch wiring)
  • Integrated overcurrent protective device selective to fuse
  • max. voltage of remote indication (AC)
  • distance to grounded or conductive parts
  • max. overcurrent protective device (V-type wiring)
  • max. voltage of remote indication (DC)
  • max. current of remote indication (AC)
  • transition surge current rating
  • Valuelist SPD type (IEC 61643)
  • max. discharge current (8/20) µs (N-PE)
  • max. discharge current (8/20) µs (L-N)
  • max. discharge current (8/20) µs (L-PE(N))
  • Valuelist type of remote indication contact
  • Valuelist characteristic of backup fuse
  • nominal discharge current (8/20) µs (L-PE(N))
  • min. cross-section of the remote indication (rigid)
  • Valuelist remote indication integrated
  • total discharge current (10/350) µs
  • Valuelist configuration of SPD
  • impulse discharge current (10/350) µs (N-PE)
  • Valuelist number of ports
  • impulse discharge current (10/350) µs (L-N)
  • nominal discharge current (8/20) µs (N-PE)
  • impulse discharge current (10/350) µs (L-PE(N))
  • max. continuous operating voltage AC
  • short-circuit breaking capacity
  • Valuelist Assembly type
  • Contents per packing unit
  • Valuelist Approval certificates
  • depth of packing
  • Valuelist connection method of the remote indication
  • max. allowed elevation above mean sea level
  • Valuelist nominal voltage (for AC)
  • residual current AC
  • Valuelist test standard
  • max. current of remote indication (DC)
  • Valuelist no leakage current
  • max. cross-section of the remote indication (flexible)
  • Valuelist TOV - behaviour (120 min)
  • Valuelist SPD failure mode
  • max. cross-section of the remote indication (rigid)
  • Valuelist TOV - behaviour (200 ms)
  • min. cross-section of the remote indication (flexible)
  • Valuelist protective element pluggable
  • max. continuous operating voltage AC (N-G)
  • voltage protection rating (L-N) (UL 1449)
  • short-circuit current rating acc. to UL 1449
  • load current rating AC (UL 1449)
  • Valuelist min. wire cross-section, alarm circuit (UL 1449)
  • fuse [option 1], voltage (UL 1449)
  • fuse [option 1], current rating (UL 1449)
  • fuse [option 2], class
  • AC power frequency
  • measured limiting voltage (N-G) (UL 1449)
  • Valuelist max. wire cross-section, alarm circuit (UL 1449)
  • measured limiting voltage (L-L) (UL 1449)
  • Valuelist min. wire cross-section (UL 1449)
  • max. continuous operating voltage AC (L-L)
  • max. continuous operating voltage AC (L-N)
  • voltage protection rating (L-G) (UL 1449)
  • voltage protection rating (N-G) (UL 1449)
  • min. torque, alarm circuit (UL 1449)
  • Valuelist internal disconnect feature (UL 1449)
  • voltage protection rating (L-L) (UL 1449)
  • max. torque, alarm circuit (UL 1449)
  • measured limiting voltage (L-N) (UL 1449)
  • Valuelist max. wire cross-section (UL 1449)
  • measured limiting voltage (L-G) (UL 1449)
  • min. torque (UL 1449)
  • max. torque (UL 1449)
  • Valuelist mounting method (UL 1449)
  • max. allowed elevation above mean sea level, ft (UL 1449)
  • min. humidity during operation (UL 1449)
  • max. humidity during operation (UL 1449)
  • min. temperature during operation, °F (UL 1449)
  • max. temperature during operation, °F (UL 1449)
  • operating voltage, alarm circuit DC (UL 1449)
  • Valuelist operating voltage AC (UL 1449)
  • max. temperature during operation, °C (UL 1449)
  • nominal discharge current (UL 1449)
  • min. temperature during operation, °C (UL 1449)
  • max. continuous operating voltage AC (L-G)
  • surge current capacity per phase (UL 1449)
  • max. allowed elevation above mean sea level, m (UL 1449)
  • Valuelist mode of protection AC (UL 1449)
  • Valuelist service configuration (UL 1449)
  • Valuelist edition of UL 1449 used for testing
  • Valuelist type of load, alarm circuit (UL1449)
  • Valuelist UL Category Code number (UL 1449)
  • AC frequency, alarm circuit (UL 1449)
  • nominal load current, alarm circuit AC (UL1449)
  • nominal load current, alarm circuit DC (UL 1449)
  • fuse [option 2], voltage (UL 1449)
  • fuse [option 1], class
  • fuse [option 2], current rating (UL 1449)
  • Valuelist SPD Type (UL 1449)
  • Valuelist type of listing (UL 1449)
  • operating voltage, alarm circuit AC (UL 1449)
  • Valuelist number of ports (UL 1449)
  • Valuelist degree of protection (IP) (UL1449)
X

We need your consent

This website uses necessary cookies to ensure the operation of the website. There is no analysis of user behavior by third parties. You can find detailed information about the use of cookies in our privacy policy.