Classification: 36030403 [AKL251018]

Preferred name 36-03-04-03 Silo, bunker (open)
IRDI 0173-1#01-AKL251#018
Already on the watchlist: 0 of max. 4

BASIC Properties: Silo, bunker (open)

  • Material description of the room1
  • Volume of the room2
  • Construction form of the container bottom
  • Reference norm material, design
  • Valuelist Construction type
  • Reference norm of the surface properties, room1
  • Number of supports nominal group 3
  • Reference norm of the explosion protection
  • Code of the manufacturer declaration
  • Reference norm material of the room3
  • Reference norm material of the device flange
  • Type description
  • Material description of the room2
  • Reference norm the number of muffs
  • Volume of the room3
  • item list number of manufacturer
  • Reference norm wind load
  • Material number of the design
  • Material number of the carrying construction
  • Construction of the thermal transfer surface room3/room1
  • Material number of the coating, room1
  • drawing number of manufacturer
  • Nominal volume
  • Material description of the carrying construction
  • Valuelist material code of coating (external surface)
  • Reference norm material, design, room 3
  • Volume of the room1
  • Reference norm material of the static seal, room1
  • Material description of the device flange
  • Material number of the room2
  • Material number of the room3
  • Material number of the design room3
  • Reference norm of the dampening
  • supplier of the identifier
  • Construction of the thermal transfer surface room2/room1
  • Reference norm material of the coating, room1
  • Max. permissible overpressure PS1+ at TS1, room3
  • Max. permissible overpressure PS1+ at TS1, room2
  • Valuelist explosion protection marking
  • Number of rooms
  • design
  • Max. permissible underpressure PS2- at TS2, room3
  • Max. permissible underpressure PS1- at TS1, room3
  • Max. permissible overpressure PS2+ at TS2, room3
  • Construction form of the holder, dampening
  • Construction form of the carrying construction
  • Nominal diameter of the room1
  • overall width
  • Max. permissible operating temperature at TS1, room3
  • Thermal transfer surface room1/room3
  • Thermal transfer surface room1/room2
  • Construction form of the dampening
  • description of class
  • overall length
  • Min. permissible operating temperature at TS2, room1
  • Opening tilt of the funnel
  • Valuelist Earthquake load to be applied
  • over all height
  • thickness of coating (external surface)
  • Thickness of the coating, room1
  • Valuelist Wind load to be applied
  • Valuelist conformity declaration present
  • Valuelist Manufacturer declaration present
  • Valuelist Explosion protection certificate present
  • Supplier product family
  • Supplier product description
  • name of supplier
  • GLN of supplier
  • Supplier product type
  • Supplier product order suffix
  • Supplier product root
  • HS-Code of the WCO
  • Valuelist Use of customs tariff number
  • Valuelist Type of customs tariff number
  • Customs tariff number
  • Max. permissible underpressure PS1- at TS1, room1
  • Max. permissible underpressure PS2- at TS2, room2
  • Max. permissible underpressure PS2- at TS2, room1
  • Max. permissible overpressure PS1+ at TS1, room1
  • Max. permissible overpressure PS2+ at TS2, room1
  • Thickness of the dampening
  • Max. permissible underpressure PS1- at TS1, room2
  • Wall thickness of the container case
  • Reference norm material of the room1
  • Nominal width of the device flange
  • Number of the discharge aids
  • Max. permissible overpressure PS2+ at TS2, room2
  • order code of manufacturer
  • reference standard
  • Material number of the device flange
  • reference standard for material of the coating (external surface)
  • Earthquake zone
  • Max. permissible operating weight
  • material of coating (external surface)
  • Reference norm of the static seal, room1
  • code of class
  • Material number of the room1
  • Construction of the static seal, room1
  • Material number of the static seal, room1
  • code of conformity evaluation
  • Reference norm of the earthquake zone
  • Material description of the coating, room1
  • Material description of the design room2
  • Valuelist guideline for conformity declaration
  • Material description of the room3
  • Material description of the design room3
  • Number of supports nominal group 2
  • classification system
  • Material description of the design
  • Reference norm of the coating, room1
  • Number of device flanges
  • fabrication number
  • Reference norm material, design, room 2
  • Construction of the seal surface, device flange
  • Material number of the design room2
  • Material description of the static seal, room1
  • Reference norm material of the room2
  • Reference norm of the device flange
  • empty weight
  • reference standard for the coating (external surface)
  • Number of supports nominal group 1
  • Wind load zone
  • Product country of origin
  • Reference norm material of the carrying construction
  • address of additional link
  • GTIN
  • product article number of manufacturer
  • Manufacturer name
  • Manufacturer product order suffix
  • Brand
  • Manufacturer product description
  • Product type
  • Manufacturer product designation
  • Manufacturer product family
  • Manufacturer product root
  • URI of manufacturer
  • GLN of manufacturer
  • URI of the product
  • product article number of supplier
  • Supplier product designation
  • Type of coating application, room 1
  • Type of coating application, external surface
  • Valuelist construction size
  • Valuelist Dampening holder present
  • Construction type of the discharge aid
  • country of manufacturer
  • Layout of the installation venue
  • Surface properties of the room1
  • Min. permissible operating temperature at TS2, room3
  • Min. permissible operating temperature at TS2, room2
  • Max. permissible operating temperature at TS1, room2
  • Max. permissible operating temperature at TS1, room1