Classification: 36100190 [AKL447018]

Preferred name 36-10-01-90 Centrifuge (for liquids, unspecified)
Definition Sub-group (4th level) for objects that cannot be classified into other specified sub-groups in the existing structure, but that are classified to their parent-class on the 3rd level
IRDI 0173-1#01-AKL447#018
Already on the watchlist: 0 of max. 4

BASIC Properties: Centrifuge (for liquids, unspecified)

  • Max. permissible overpressure PS1+ at TS1, room1
  • Max. permissible underpressure PS2- at TS2, room1
  • Max. permissible underpressure PS2- at TS2, room2
  • Max. permissible underpressure PS1- at TS1, room1
  • Max. permissible underpressure PS1- at TS1, room2
  • Max. permissible overpressure PS2+ at TS2, room1
  • Thickness of the dampening
  • Reference norm material of the room1
  • reference standard for the shaft end
  • reference standard for material of the coating (external surface)
  • Valuelist Nominal pressure of the muffs, A1
  • Valuelist Construction form of the seal surface, connection, muff A2
  • reference standard
  • code of class
  • Separation degree at maximum volume flow
  • Reference norm of the static seal, room1
  • Supplier product description
  • Supplier product family
  • Supplier product root
  • Supplier product order suffix
  • Supplier product type
  • GLN of supplier
  • Customs tariff number
  • Valuelist Type of customs tariff number
  • Valuelist Use of customs tariff number
  • HS-Code of the WCO
  • Valuelist Construction form of the coupling
  • Manufacturer product description
  • Brand
  • Manufacturer product order suffix
  • Manufacturer product root
  • Manufacturer product family
  • Manufacturer product designation
  • Product type
  • URI of the product
  • GLN of manufacturer
  • URI of manufacturer
  • Supplier product designation
  • product article number of supplier
  • name of supplier
  • address of additional link
  • GTIN
  • Manufacturer name
  • product article number of manufacturer
  • order code of manufacturer
  • Valuelist construction size
  • Valuelist Type of drive
  • Type of coating application, external surface
  • Type of coating application, room 1
  • Construction type of the connection, muff A3
  • Construction type of the connection, muff A2
  • Construction type of the connection, muff A1
  • country of manufacturer
  • Load moment of the drive
  • Operation type time sequence of the drive
  • Rotational direction of the drive
  • type of dynamic seal
  • Type of storage temperature monitoring
  • Max. permissible operating temperature at TS1, room1
  • Max. permissible operating temperature at TS1, room2
  • Min. permissible operating temperature at TS2, room2
  • Thermal transfer surface room1/room2
  • Construction form of the shaft bearing
  • Length of the drum
  • Internal diameter of the drum
  • Min. permissible operating temperature at TS2, room1
  • Thickness of the coating, room1
  • thickness of coating (external surface)
  • description of class
  • overall length
  • over all height
  • Moment of inertia of the drive
  • Valuelist Explosion protection certificate present
  • Valuelist Manufacturer declaration present
  • Valuelist conformity declaration present
  • Valuelist Inerting possible
  • Valuelist Gas-proof design present
  • Material number of the drum
  • Max. permissible overpressure PS2+ at TS2, room2
  • Valuelist explosion protection marking
  • Max. permissible overpressure PS1+ at TS1, room2
  • Max. speed of the drive
  • Min. speed of the drive
  • Nominal speed of the drive
  • Measurement speed of the electric motor
  • Max. permissible speed of the centrifuge
  • design
  • overall width
  • Construction form of the carrying construction
  • Construction form of the holder, dampening
  • Construction form of the dampening
  • Construction form of the electric motor
  • Construction form of the transmission
  • Material number of the coating, room1
  • Construction form of the seal surface, connection, muff A3
  • Reference norm material of the static seal, room1
  • Volume of the room1
  • Material description of the shaft
  • Valuelist material code of coating (external surface)
  • Material number of the drive housing
  • Material number of the room2
  • Nominal width of the muffs, A3
  • Construction of the transmission
  • Reference norm material of the coating, room1
  • Valuelist Nominal width of the muffs, A1
  • Reference norm of the explosion protection of the electric motor
  • Construction of the thermal transfer surface room2/room1
  • supplier of the identifier
  • Reference norm of the dampening
  • design of dynamic seal
  • Reference norm material of the shaft
  • Valuelist Nominal pressure of the muffs, A2
  • item list number of manufacturer
  • Classification system of the electric motor
  • reference standard for the dynamic seal
  • Construction of the electric motor
  • Reference norm the number of muffs
  • Valuelist Construction form of the seal surface, connection, muff A1
  • Explosion protection device group of the electric motor
  • Material description of the room2
  • Material number of the carrying construction
  • Material number of the design
  • Valuelist Nominal width of the muffs, A2
  • Material description of the carrying construction
  • drawing number of manufacturer
  • Material description of the room1
  • Nominal pressure of the muffs, A3
  • Class code of the electric motor
  • Reference norm of the explosion protection
  • Classification system of the transmission
  • Explosion protection Type of 'e' protection of the electric motor
  • material code of dynamic seal
  • Number of supports nominal group 3
  • Valuelist Construction type
  • style of shaft end
  • Measurement tension of the electric motor
  • material code of dynamic seal
  • Type description
  • Reference norm material of the drum
  • Max. sound pressure level
  • Code of the manufacturer declaration
  • empty weight
  • Explosion protection temperature class of the electric motor
  • Measurement performance of the electric motor
  • Explosion protection code of the electric motor
  • Reference norm material of the room2
  • Reference norm material of the drive housing
  • Reference norm material of the carrying construction
  • Initial breakaway torque of the drive
  • Product country of origin
  • Max. volume flow am inlet
  • Torque at nominal speed, drive
  • Number of supports nominal group 1
  • Reference norm material, design
  • Construction of the connection, muff A3
  • Material description of the drive housing
  • Volume of the room2
  • fabrication number
  • Reference norm of the connection, muff A3
  • Reference norm of the coating, room1
  • Reference norm protection type of electric motor
  • Material description of the design
  • Reference norm of the connection, muff A2
  • Material description of the static seal, room1
  • material of dynamic seal
  • Explosion protection category for devices , electric motor
  • Construction of the connection, muff A1
  • Material number of the design room2
  • Transmission ratio of the transmission
  • Class code of the transmission
  • Reference norm material, design, room 2
  • Valuelist Material number of the shaft
  • reference standard for the coating (external surface)
  • Construction of the connection, muff A2
  • material of coating (external surface)
  • Max. permissible operating weight
  • code of conformity evaluation
  • Material number of the static seal, room1
  • Reference norm of the connection, muff A1
  • Protection type class of the electric motor
  • Construction of the static seal, room1
  • Material number of the room1
  • Material description of the drum
  • Valuelist guideline for conformity declaration
  • Material description of the design room2
  • Material description of the coating, room1
  • Shaft performance for nominal speed, drive
  • classification system
  • Number of supports nominal group 2
X

We need your consent

This website uses necessary cookies to ensure the operation of the website. There is no analysis of user behavior by third parties. You can find detailed information about the use of cookies in our privacy policy.