Search the ECLASS content

ECLASS offers you the opportunity to have a look at and search the latest ECLASS Releases free of charge. The search function is intuitive and allows you to get to know the standard in a quick and non-bureaucratic manner.

How to use the ECLASS search

Please first select ...

  • whether you want to search ECLASS Basic or Advanced
  • in which Release version you want to search
  • in which language you want to search
  • whether you want to search in the classes or for properties, values etc.

Then enter a search term (e.g. "pencil") and click on "Search".
 

Please note that the application of the ECLASS Standard requires a license. (see also ECLASS Terms of Use)

eclass image

Classification: 36410304 [AAZ377021]

Preferred name 36-41-03-04 Vane-cell pump
Keywords Blade type pump Liquid ring pump Vane pump
IRDI 0173-1#01-AAZ377#021
Already on the watchlist: 0 of max. 4

BASIC Properties: Vane-cell pump

  • frequency
  • energy consumption
  • current
  • torque
  • DC link voltage
  • voltage
  • motor current
  • mean rated velocity at outlet
  • total head at outlet area of the pump
  • power factor
  • motor voltage
  • motor temperature
  • DC link current
  • availability
  • time based availability
  • intrinsic reliability
  • intrinsic maintainability
  • production based availability
  • operational reliability
  • maintainability
  • durability
  • Valuelist auxiliary device fault - installation
  • Valuelist auxiliary device fault - humidity electronics
  • Valuelist obsolescence
  • instantaneous availability
  • expected reliability
  • Reliability according to norm
  • Valuelist distribution type
  • distribution priority
  • exchange time
  • maximum number of pumps in operation
  • Valuelist pump role
  • pump collective Ids
  • Valuelist operation mode
  • Valuelist exchange mode
  • atmospheric pressure
  • hydraulic efficiency
  • height of the outlet manometer
  • maximum dynamic sealing pressure
  • exchange time difference
  • Number of Pumps
  • height of the inlet manometer
  • pump rated power input
  • pump mechanical power losses
  • pump efficiency
  • pump best efficiency
  • overall efficiency
  • useful life
  • minimum allowable stable flow
  • mechanical efficiency
  • Valuelist direction
  • category
  • driver power input
  • ID carrier
  • severity
  • number of failures
  • corrective maintenance time
  • Valuelist process fluid fault - dry
  • Valuelist electronic fault - supply voltage low
  • Valuelist electronic fault - supply voltage high
  • Valuelist electronic fault - supply voltage
  • Valuelist electronic fault - winding temperature
  • Valuelist process fluid fault - pressure
  • Valuelist process fluid fault - liquid
  • Valuelist process fluid fault - gas
  • Valuelist mechanical fault - brake overheat
  • Valuelist mechanical fault - bearing fault
  • Valuelist mechanical fault - axial bearing overheat
  • Valuelist mechanical fault - axial bearing fault
  • Valuelist mechanical fault - axial bearing abrasion
  • Valuelist process fluid fault - stall
  • Valuelist process fluid fault - solid
  • Valuelist pump operation fault - accessory liquid flow
  • Valuelist auxiliary device fault - sensor element
  • Valuelist process fluid fault - flow
  • Valuelist mechanical fault - brake chopper
  • Valuelist process fluid fault - viscosity
  • Valuelist process fluid fault - temperature
  • Valuelist auxiliary device fault - vibration
  • Valuelist auxiliary device fault - temperature shock
  • Valuelist auxiliary device fault - start up
  • Valuelist software fault - memory
  • Valuelist auxiliary device fault - process influence
  • Valuelist auxiliary device fault - peripheral
  • Valuelist auxiliary device fault - parameter setting
  • Valuelist auxiliary device fault - wear reserve operation
  • Valuelist auxiliary device fault - interruption
  • Valuelist hardware fault - DC link supply
  • Valuelist auxiliary device fault - overloading
  • Valuelist hardware fault - control circuit
  • Valuelist auxiliary device fault - fouling
  • Valuelist auxiliary device fault - measured material electronics
  • Valuelist auxiliary device fault - material electronics
  • Valuelist auxiliary device fault - line length
  • Valuelist hardware fault - measure circuit
  • Valuelist hardware fault - IONA
  • Valuelist hardware fault - eprom
  • Valuelist hardware fault - uP
  • Valuelist auxiliary device fault - operating conditions
  • Valuelist hardware fault - computing circuit
  • Valuelist auxiliary device fault - mechanical damage
  • Valuelist hardware fault - network NA
  • Valuelist auxiliary device fault - electromagnetic interference
  • Valuelist auxiliary device fault - deviation
  • Valuelist auxiliary device fault - corrosion
  • Valuelist auxiliary device fault - communication error
  • Valuelist hardware fault - ram
  • Valuelist hardware fault - power supply
  • Valuelist auxiliary device fault - auxiliary power range
  • Valuelist auxiliary device fault - auxiliary power pole
  • Valuelist electronic fault - supply frequency
  • Valuelist auxiliary device fault - energy supply
  • Valuelist auxiliary device fault - electronic fault
  • Valuelist electronic fault - voltage inside device
  • Valuelist electronic fault - supply frequency low
  • Valuelist auxiliary device fault - exciter error
  • Valuelist electronic fault - supply frequency high
  • Valuelist auxiliary device fault - evaluation electronics
  • Valuelist hardware fault - communication
  • Valuelist pump operation fault - coolant high
  • Valuelist pump operation fault - coolant flow
  • Valuelist pump operation fault - converter overheat
  • Valuelist pump operation fault - case overheat
  • Valuelist pump operation fault - ambient temperature
  • Valuelist pump operation fault - accessory liquid pressure
  • Valuelist pump operation fault - accessory liquid overheat
  • Valuelist pump operation fault - turbine operation
  • Valuelist pump operation fault - torque limit
  • Valuelist electronic fault - field circuit
  • Valuelist auxiliary device fault - auxiliary medium absence
  • Valuelist pump operation fault - controller overheat
  • Valuelist pump operation fault - TMS failure
  • Valuelist pump operation fault - velocity limit
  • Valuelist pump operation fault - under speed
  • Valuelist electronic fault - short circuit
  • Valuelist electronic fault - phase failure
  • Valuelist electronic fault - insulation resistance
  • Valuelist electronic fault - installation fault
  • Valuelist electronic fault - current inside device
  • Valuelist auxiliary device fault - ambient temperature
  • Valuelist auxiliary device fault - actuator element
  • Valuelist pump operation fault - wear reserve exhausted
  • Valuelist electronic fault - short to earth
  • Valuelist pump operation fault - operation fault
  • Valuelist pump operation fault - motor overheat
  • Valuelist pump operation fault - motor humidity
  • Valuelist auxiliary device fault - auxiliary medium insufficiency
  • Valuelist electronic fault - supply current low
  • Valuelist electronic fault - supply current high
  • Valuelist electronic fault - supply current
  • Valuelist software fault - application
  • Valuelist process fluid fault - blockage
  • Valuelist software fault - software reset
  • Valuelist software fault - parameter
  • Valuelist software fault - control
  • Valuelist electronic fault - armature circuit
  • Valuelist software fault - communication
  • Valuelist auxiliary device fault - wear reserve wear
  • Valuelist pump operation fault - coolant overheat
  • Valuelist pump operation fault - coolant low
  • Valuelist pump operation fault - leakage
  • Valuelist pump operation fault - generator operation
  • Valuelist software fault - OS
  • Valuelist process fluid fault - condensation
  • Valuelist process fluid fault - cavitation
  • Valuelist pump operation fault - deceleration
  • Valuelist pump operation fault - lubricant
  • Valuelist mechanical fault - excess vibration
  • Valuelist mechanical fault - radial bearing fault
  • Valuelist mechanical fault - radial bearing abrasion
  • Valuelist pump operation fault - drive overheat
  • Valuelist pump operation fault - dirty impeller
  • Valuelist pump operation fault - maximum operation time
  • Valuelist pump operation fault - maximum number starts
  • Valuelist pump operation fault - accessory liquid high
  • Valuelist mechanical fault - rotor station rubbing
  • Valuelist mechanical fault - rotor blocked
  • Valuelist mechanical fault - radial bearing overheat
  • Valuelist mechanical fault - misalignment
  • Valuelist mechanical fault - gap wear
  • Valuelist pump operation fault - accessory liquid low
  • Valuelist mechanical fault - unbalance
  • bearing temperature
  • pump power output
  • axial rotor position
  • hydraulic efficiency
  • electronic temperature
  • radial load of pump rotor
  • clearance flow
  • pump temperature
  • fluid temperature
  • sound energy level
  • housing temperature
  • sound energy
  • Speed
  • sound energy
  • declaration of conformity
  • design radial load
  • design axial load
  • outlet temperature of the pump
  • sound power
  • sound energy level
  • maximum axial load
  • Valuelist device type
  • pump power input curve
  • min. temperature
  • possible fluid
  • pump efficiency curve
  • pump curve
  • maximum radial load
  • Valuelist pump operation fault - over load
  • Valuelist pump operation fault - time out
  • Valuelist pump operation fault - temperature fault
  • criticality
  • Valuelist pump operation fault - maximum starts at time
  • Valuelist pump operation fault - synchronisation
  • Valuelist pump operation fault - partial load
  • Valuelist pump operation fault - over speed
  • inlet temperature of the pump
  • next inspection date
  • last inspection date
  • Valuelist failure
  • Min allowable outet pressure
  • active preventive maintenance time
  • sound power
  • lubricating oil consumption
  • installation date
  • preventive maintenance time
  • next servicing date
  • last servicing date
  • axial load of pump rotor
  • pump efficiency
  • power loss due to internal leakage
  • overall efficiency
  • level
  • leakage rate of flow
  • mechanical efficiency
  • number of starts
  • type of product
  • manufacturer URI
  • asset ID
  • initial operation date
  • product code
  • URL
  • markings
  • model
  • software version
  • month of construction
  • year of construction
  • component name
  • derivative action coefficient
  • controller output variable
  • hardware version
  • Valuelist Address of company representative
  • National stock number
  • control difference variable
  • command variable
  • controlled variable
  • integral action coefficient
  • final controlled variable
  • sound pressure level
  • min. ambient temperature during operation
  • Control types
  • max. air humidity
  • Valuelist supported protocol
  • Valuelist Controllable
  • max. temperature
  • min. air humidity
  • Rotational direction of the pump
  • installation NPSH curve
  • max. ambient temperature
  • Quick-acting speed
  • Sound output level
  • minimum allowable thermal flow
  • leakage rate of flow
  • optimum rate of flow
  • net positive suction head required for a drop of 3 %
  • minimum allowable head
  • pump NPSH curve
  • net positive suction head required
  • maximum allowable head
  • day of construction
  • location
  • device class
  • balancing rate of flow
  • Counterpressure
  • Coolant temperature
  • Nominal size of nozzle/pipe
  • height of the inlet connection
  • volumetric efficiency
  • Valuelist nominal pressure (PN) of the flange
  • set control mode
  • set operation mode
  • Valuelist enable
  • Valuelist control inversion
  • total head at inlet area of the pump
  • mean rated velocity at inlet
  • height of the pump
  • Valuelist multi-phase
  • height of the inlet side of the installation
  • Valuelist actual operation mode
  • Valuelist actual control mode
  • Valuelist reverse rotating direction
  • Valuelist external signal
  • Valuelist operating mode
  • height of the outlet side of the installation
  • min. temperature range
  • mean time between failures (MTBF)
  • required control mode
  • gas content
  • reference plane
  • fluid
  • Pre-charge pressure
  • piston velocity
  • clearance volume
  • proportional action coefficient
  • operating mode
  • dead time
  • Valuelist property-status
  • Valuelist on/off
  • geometric displacement volume
  • slip flow
  • geometrical flow
  • Stroke volume
  • total head at outlet area of the installation
  • total head at inlet area of the installation
  • installation total head
  • manipulated variable
  • feedback variable
  • reference variable
  • kinematic viscosity
  • differential pressure
  • Dynamic viscosity
  • lift circulating pump
  • Installation inlet pressure
  • Instalation outlet pressure
  • net positive suction head
  • Mass flow
  • nominal voltage
  • Valuelist energy efficiency class (motor)
  • height of the outlet connection
  • nominal power consumption
  • Nominal speed
  • norminal frequence
  • Manufacturer order code
  • Useful life
  • maximum ambient temperature (during operation)
  • working temperature
  • max. temperature range
  • Valuelist Field bus system
  • solids volume fraction
  • minimum ambient temperature (during operation)
  • minimum feed height
  • on off cycle
  • Min inlet pressure
  • Valuelist fault action
  • Relief valve set pressure
  • Relief valve locking pressure
  • Valuelist discrete output value
  • fault value
  • Max. nominal frequency
  • Power factor (cos phi)
  • Min. nominal frequency
  • enclosure type no/class
  • Relief valve counter-pressure
  • Relief valve overpressure
  • motor efficiency
  • minimum dynamic viscosity at design temperature
  • maximum dynamic viscosity at design temperature
  • Volume flow of the sealing liquid
  • Filling volume of the equipment
  • Construction form of the electric motor
  • overall width
  • Design temperature
  • NPSH-nominal
  • Measurement speed of the electric motor
  • Nominal speed of the drive
  • Min. speed of the drive
  • Height over all, base plate
  • normal feed flow
  • Construction type conveying element
  • design
  • maximum rotation speed of the pump
  • width over all, base plate
  • Min. feed pressure, suction-side
  • nominal feed height
  • Max. permissible overpressure PS1+ at TS1, room2
  • Max. speed of the drive
  • Rotation speed pump
  • minimum density at design temperature
  • maximum density at design temperature
  • required supply pressure
  • Setting pressure of the overflow valve
  • Max. permissible overpressure PS2+ at TS2, room2
  • Max. permissible overpressure PS2+ at TS2, room1
  • Max. permissible pressure differential
  • Max. feed pressure, suction-side
  • Max. feed pressure suction-side
  • Valuelist explosion protection marking
  • Max. permissible operating temperature at TS1, room1
  • Max. work temperature
  • Min. work temperature
  • type of dynamic seal
  • Min. permissible operating temperature at TS2, room2
  • Max. permissible operating temperature at TS1, room2
  • Operation type time sequence of the drive
  • Load moment of the drive
  • country of manufacturer
  • Construction type of the connection, muff A1
  • material code of housing
  • material of housing
  • Type of set-up
  • Rotational direction of the drive
  • Valuelist Overflow valve integrated
  • Valuelist Heater/cooler present
  • Valuelist conformity declaration present
  • Valuelist Manufacturer declaration present
  • Construction type of the connection, muff A2
  • Type of coating application, room 1
  • Valuelist Type of drive
  • Valuelist construction size
  • description of class
  • Thickness of the coating, room1
  • Min. permissible operating temperature at TS2, room1
  • Construction form of the transmission
  • Valuelist Explosion protection certificate present
  • Moment of inertia of the drive
  • over all height
  • overall length
  • Measurement tension of the electric motor
  • Material number of the bearing neck
  • Material description of the secondary sealing element
  • Valuelist Construction type
  • design of dynamic seal
  • Code of the manufacturer declaration
  • Type description
  • material code of dynamic seal
  • Reference norm of the explosion protection
  • Class code of the electric motor
  • Reference norm material of the shaft protection sleeve
  • Material description of the drive housing
  • Reference norm material of the can
  • material code of dynamic seal
  • Explosion protection Type of 'e' protection of the electric motor
  • Classification system of the transmission
  • Initial breakaway torque of the drive
  • Feed volume per revolution
  • Reference norm material of the drive housing
  • Explosion protection code of the electric motor
  • Reference norm of the static seal, housing
  • Torque at nominal speed, drive
  • Material description of the stator
  • Product country of origin
  • Material description of the static seal, housing
  • Explosion protection temperature class of the electric motor
  • Material description of the pumping medium
  • empty weight
  • Material number of the pumping medium
  • Measurement performance of the electric motor
  • Material number of the shaft protective sleeve
  • Reference norm material of the stator
  • Material description of the displacement units
  • Construction of the static seal, housing
  • Material number of the secondary sealing element
  • supplier of the identifier
  • Length over all, base plate
  • Max. permissible underpressure PS1- at TS1, room2
  • Max. permissible underpressure PS1- at TS1, room1
  • Valuelist Sealing type
  • Construction of the transmission
  • Material number of the stator
  • Material number of the drive housing
  • Material description of the shaft
  • Reference norm of the explosion protection of the electric motor
  • Material number of the displacement units
  • Valuelist Nominal width of the muffs, A1
  • Reference norm material of the coating, room1
  • Manufacturer's name of the sealing
  • reference standard for material of the housing
  • Material number of the rotor
  • Explosion protection device group of the electric motor
  • Material number of the coating, room1
  • Type of the seal
  • drawing number of manufacturer
  • Valuelist Nominal width of the muffs, A2
  • Classification system of the electric motor
  • item list number of manufacturer
  • Valuelist Nominal pressure of the muffs, A2
  • Reference norm material of the shaft
  • Valuelist Construction form of the seal surface, connection, muff A1
  • Construction of the electric motor
  • Reference norm of the secondary sealing element material
  • reference standard for the dynamic seal
  • Valuelist Construction form of the seal surface, connection, muff A2
  • Valuelist Nominal pressure of the muffs, A1
  • Reference norm material of the displacement units
  • Min. feed flow
  • Material description of the can
  • code of class
  • Material description of the plain bearing bush
  • reference standard
  • Valuelist Construction form of the coupling
  • HS-Code of the WCO
  • Max. permissible underpressure PS2- at TS2, room2
  • Max. permissible underpressure PS2- at TS2, room1
  • Max. permissible overpressure PS1+ at TS1, room1
  • Max. overpressure of the shaft seal
  • GLN of supplier
  • Valuelist Use of customs tariff number
  • Valuelist Type of customs tariff number
  • Customs tariff number
  • Supplier product description
  • name of supplier
  • product article number of supplier
  • Supplier product type
  • Supplier product order suffix
  • Supplier product root
  • Supplier product family
  • Construction of the connection, muff A1
  • Reference norm material of the static seal, housing
  • Explosion protection category for devices , electric motor
  • material of dynamic seal
  • Valuelist Material number of the shaft
  • Reference norm material of the rotor
  • Class code of the transmission
  • Transmission ratio of the transmission
  • Year of construction
  • fabrication number
  • Material number of the plain bearing bush
  • classification system
  • Reference norm of the connection, muff A2
  • Material description of the bearing neck
  • Reference norm protection type of electric motor
  • Reference norm of the coating, room1
  • Material description of the coating, room1
  • Material description of the rotor
  • Valuelist guideline for conformity declaration
  • Max. feed flow
  • Reference norm material, pumping medium
  • Shaft performance for nominal speed, drive
  • Valuelist Material number of the static seal, housing
  • Material description of the shaft protection sleeve
  • Reference norm of the connection, muff A1
  • code of conformity evaluation
  • Construction of the connection, muff A2
  • Type description of the sealing
  • Material number of the can
  • Reference norm of the plain bearing bush material
  • Reference norm of the bearing neck material
  • Protection type class of the electric motor
  • URI of manufacturer
  • GLN of manufacturer
  • URI of the product
  • Product type
  • Supplier product designation
  • Brand
  • Manufacturer product description
  • Manufacturer product designation
  • Manufacturer product family
  • Manufacturer product root
  • Manufacturer product order suffix
  • product article number of manufacturer
  • Manufacturer name
  • GTIN
  • address of additional link
  • Valuelist state of the item
  • standby time
  • mean repair time
  • maintenance time
  • Required net positive inlet pressure
  • failure rate
  • active maintenance time
  • operating time to failure
  • operating time between failures
  • Valuelist maintenance level
  • up time
  • idle time
  • time to restoration
  • mean downtime
  • operating time
  • mean time to restauration
  • external disabled time
  • down time
  • repair time
  • Valuelist pump kick mode
  • redundant pump Ids
  • Valuelist discrete input value
  • pump kick time difference
  • pump kick time
  • Explosion protection category for devices, pump
  • Object identifier within a plant
  • Explosion protection code of the pump
  • Explosion protection explosion group of the electric motor
  • Explosion protection Type of 'e' protection of the pump
  • Explosion protection explosion group of the pump
  • Explosion protection device group of the pump
  • Explosion protection temperature class of the pump
  • height of the NPSH datum plane
  • mean rated velocity at outlet area of the installation
  • Design differential pressure
  • mean rated velocity at inlet area of the installation
  • Explosion protection Equipment Protection Level (EPL) of the pump
  • Explosion protection Equipment Protection Level (EPL) of the pump
  • pump total head
  • installation total head
  • vapor pressure (gauge)
  • density
  • kinematic viscosity
  • net positive suction head available
  • total head at outlet area of the installation
  • total head at inlet area of the installation
  • valve seat velocity
  • volumetric efficiency
  • valve spill velocity
  • inlet area of the pump
  • Min allowable inlet pressure
X

We need your consent

This website uses necessary cookies to ensure the operation of the website. There is no analysis of user behavior by third parties. You can find detailed information about the use of cookies in our privacy policy.