Classification: 36410304 [AAZ377020]

Preferred name 36-41-03-04 Vane-cell pump
Keywords Blade type pump Liquid ring pump Vane pump
IRDI 0173-1#01-AAZ377#020
Already on the watchlist: 0 of max. 4

BASIC Properties: Vane-cell pump

  • Reference norm of the connection, muff A1
  • Protection type class of the electric motor
  • Reference norm of the bearing neck material
  • Reference norm of the plain bearing bush material
  • Material description of the can
  • Type description of the sealing
  • Construction of the connection, muff A2
  • code of conformity evaluation
  • Material description of the coating, room1
  • Material description of the shaft protection sleeve
  • Valuelist Material number of the static seal, housing
  • Shaft performance for nominal speed, drive
  • Material number of the can
  • Max. feed flow
  • Valuelist guideline for conformity declaration
  • Material description of the rotor
  • Valuelist Construction form of the coupling
  • Max. overpressure of the shaft seal
  • Max. permissible overpressure PS1+ at TS1, room1
  • Max. permissible underpressure PS2- at TS2, room1
  • Customs tariff number
  • Valuelist Type of customs tariff number
  • Valuelist Use of customs tariff number
  • HS-Code of the WCO
  • Valuelist Construction form of the seal surface, connection, muff A2
  • reference standard
  • Material description of the plain bearing bush
  • code of class
  • Max. permissible underpressure PS2- at TS2, room2
  • Min. feed flow
  • Reference norm material of the displacement units
  • Valuelist Nominal pressure of the muffs, A1
  • Material description of the static seal, housing
  • Reference norm material of the stator
  • Material number of the shaft protective sleeve
  • Measurement performance of the electric motor
  • Valuelist Material number of the shaft
  • empty weight
  • Material description of the pumping medium
  • Explosion protection temperature class of the electric motor
  • Initial breakaway torque of the drive
  • Product country of origin
  • Material description of the stator
  • Torque at nominal speed, drive
  • Material number of the pumping medium
  • Explosion protection code of the electric motor
  • Reference norm material of the drive housing
  • Feed volume per revolution
  • Year of construction
  • Reference norm of the coating, room1
  • Reference norm protection type of electric motor
  • Material description of the bearing neck
  • Reference norm material, pumping medium
  • classification system
  • Material number of the plain bearing bush
  • fabrication number
  • Construction of the connection, muff A1
  • Transmission ratio of the transmission
  • Class code of the transmission
  • Reference norm material of the rotor
  • Reference norm of the connection, muff A2
  • material of dynamic seal
  • Explosion protection category for devices , electric motor
  • Reference norm material of the static seal, housing
  • GTIN
  • address of additional link
  • name of supplier
  • Supplier product description
  • Supplier product family
  • Supplier product designation
  • product article number of supplier
  • Supplier product root
  • Supplier product order suffix
  • Supplier product type
  • GLN of supplier
  • Manufacturer product description
  • Brand
  • Manufacturer product order suffix
  • Manufacturer name
  • product article number of manufacturer
  • URI of the product
  • GLN of manufacturer
  • URI of manufacturer
  • Manufacturer product root
  • Manufacturer product family
  • Manufacturer product designation
  • Product type
  • description of class
  • overall length
  • over all height
  • Moment of inertia of the drive
  • Construction form of the electric motor
  • Construction form of the transmission
  • Min. permissible operating temperature at TS2, room1
  • Thickness of the coating, room1
  • Valuelist Overflow valve integrated
  • Valuelist construction size
  • Valuelist Type of drive
  • Type of coating application, room 1
  • Valuelist Explosion protection certificate present
  • Valuelist Manufacturer declaration present
  • Valuelist conformity declaration present
  • Valuelist Heater/cooler present
  • Measurement speed of the electric motor
  • maximum rotation speed of the pump
  • design
  • Construction type conveying element
  • Max. speed of the drive
  • Height over all, base plate
  • Min. speed of the drive
  • Nominal speed of the drive
  • minimum dynamic viscosity at design temperature
  • NPSH-nominal
  • Design temperature
  • overall width
  • normal feed flow
  • Filling volume of the equipment
  • Volume flow of the sealing liquid
  • maximum dynamic viscosity at design temperature
  • Operation type time sequence of the drive
  • Rotational direction of the drive
  • Type of set-up
  • material of housing
  • Construction type of the connection, muff A2
  • Construction type of the connection, muff A1
  • country of manufacturer
  • Load moment of the drive
  • Max. permissible operating temperature at TS1, room1
  • Max. permissible operating temperature at TS1, room2
  • Min. permissible operating temperature at TS2, room2
  • material code of housing
  • type of dynamic seal
  • Min. work temperature
  • Max. work temperature
  • Classification system of the electric motor
  • reference standard for the dynamic seal
  • Reference norm of the secondary sealing element material
  • Construction of the electric motor
  • design of dynamic seal
  • Reference norm material of the shaft
  • Valuelist Nominal pressure of the muffs, A2
  • item list number of manufacturer
  • Manufacturer's name of the sealing
  • Valuelist Nominal width of the muffs, A2
  • drawing number of manufacturer
  • Type of the seal
  • Valuelist Construction form of the seal surface, connection, muff A1
  • Explosion protection device group of the electric motor
  • Material number of the rotor
  • reference standard for material of the housing
  • Reference norm of the explosion protection
  • Classification system of the transmission
  • Explosion protection Type of 'e' protection of the electric motor
  • material code of dynamic seal
  • Reference norm of the static seal, housing
  • Material description of the drive housing
  • Reference norm material of the shaft protection sleeve
  • Class code of the electric motor
  • Measurement tension of the electric motor
  • material code of dynamic seal
  • Type description
  • Code of the manufacturer declaration
  • Reference norm material of the can
  • Valuelist Construction type
  • Material description of the secondary sealing element
  • Material number of the bearing neck
  • required supply pressure
  • Valuelist explosion protection marking
  • Max. feed pressure suction-side
  • Max. feed pressure, suction-side
  • Length over all, base plate
  • Max. permissible overpressure PS2+ at TS2, room1
  • Max. permissible overpressure PS2+ at TS2, room2
  • Setting pressure of the overflow valve
  • width over all, base plate
  • maximum density at design temperature
  • minimum density at design temperature
  • Rotation speed pump
  • Max. permissible pressure differential
  • Max. permissible overpressure PS1+ at TS1, room2
  • nominal feed height
  • Min. feed pressure, suction-side
  • Construction of the transmission
  • Reference norm material of the coating, room1
  • Valuelist Nominal width of the muffs, A1
  • Material number of the displacement units
  • Material number of the coating, room1
  • Material description of the shaft
  • Material number of the drive housing
  • Material number of the stator
  • Material description of the displacement units
  • Valuelist Sealing type
  • Max. permissible underpressure PS1- at TS1, room1
  • Max. permissible underpressure PS1- at TS1, room2
  • Reference norm of the explosion protection of the electric motor
  • supplier of the identifier
  • Material number of the secondary sealing element
  • Construction of the static seal, housing
  • height of the outlet connection
  • order code of manufacturer
  • feedback variable
  • manipulated variable
  • total head at inlet area of the installation
  • total head at outlet area of the installation
  • reference variable
  • geometrical flow
  • slip flow
  • geometric displacement volume
  • clearance volume
  • Valuelist on/off
  • Valuelist property-status
  • Stroke volume
  • volumetric efficiency
  • net positive inlet pressure
  • lift circulating pump
  • Nominal size of nozzle/pipe
  • Valuelist nominal pressure (PN) of the flange
  • net positive suction head
  • outlet pressure of the installation
  • inlet pressure of the installation
  • installation total head
  • Dynamic viscosity
  • differential pressure
  • kinematic viscosity
  • Mass flow
  • National stock number
  • Valuelist Address of company representative
  • hardware version
  • controller output variable
  • derivative action coefficient
  • component name
  • year of construction
  • month of construction
  • initial operation date
  • software version
  • operating mode
  • proportional action coefficient
  • command variable
  • piston velocity
  • pre-charge pressure
  • dead time
  • integral action coefficient
  • controlled variable
  • control difference variable
  • final controlled variable
  • minimum feed height
  • Valuelist fault action
  • fault value
  • Valuelist discrete output value
  • on off cycle
  • working temperature
  • minimum inlet pressure
  • Nominal speed
  • nominal power consumption
  • enclosure type no/class
  • Min. nominal frequency
  • Valuelist energy efficiency class (motor)
  • nominal voltage
  • norminal frequence
  • relief-valve accumulation pressure
  • relief-valve back pressure
  • relief-valve reseat pressure
  • relief-valve set pressure
  • Power factor (cos phi)
  • Max. nominal frequency
  • motor efficiency
  • Valuelist actual control mode
  • Valuelist actual operation mode
  • Valuelist control inversion
  • Valuelist enable
  • height of the pump
  • Valuelist external signal
  • Valuelist reverse rotating direction
  • total head at inlet area of the pump
  • height of the inlet connection
  • set operation mode
  • set control mode
  • mean rated velocity at inlet
  • Valuelist Field bus system
  • max. temperature range
  • mean time between failures (MTBF)
  • min. temperature range
  • maximum ambient temperature (during operation)
  • Useful life
  • minimum ambient temperature (during operation)
  • solids volume fraction
  • gas content
  • required control mode
  • height of the inlet side of the installation
  • Valuelist multi-phase
  • height of the outlet side of the installation
  • Valuelist operating mode
  • fluid
  • reference plane
  • next servicing date
  • preventive maintenance time
  • installation date
  • last inspection date
  • sound power
  • active preventive maintenance time
  • last servicing date
  • minimum allowable outet pressure
  • Valuelist failure
  • criticality
  • next inspection date
  • inlet temperature of the pump
  • clearance flow
  • radial load of pump rotor
  • electronic temperature
  • overall efficiency
  • axial rotor position
  • pump power output
  • bearing temperature
  • pump temperature
  • mechanical efficiency
  • leakage rate of flow
  • level
  • lubricating oil consumption
  • power loss due to internal leakage
  • pump efficiency
  • axial load of pump rotor
  • number of starts
  • Valuelist auxiliary device fault - actuator element
  • Valuelist auxiliary device fault - ambient temperature
  • Valuelist electronic fault - current inside device
  • Valuelist auxiliary device fault - auxiliary medium absence
  • Valuelist electronic fault - insulation resistance
  • Valuelist electronic fault - phase failure
  • Valuelist electronic fault - short circuit
  • Valuelist pump operation fault - wear reserve exhausted
  • Valuelist pump operation fault - velocity limit
  • Valuelist pump operation fault - TMS failure
  • Valuelist pump operation fault - controller overheat
  • Valuelist pump operation fault - converter overheat
  • Valuelist electronic fault - field circuit
  • Valuelist pump operation fault - torque limit
  • Valuelist pump operation fault - turbine operation
  • Valuelist pump operation fault - under speed
  • Valuelist pump operation fault - partial load
  • Valuelist pump operation fault - synchronisation
  • Valuelist pump operation fault - maximum starts at time
  • Valuelist pump operation fault - motor humidity
  • Valuelist pump operation fault - temperature fault
  • Valuelist pump operation fault - time out
  • Valuelist pump operation fault - over load
  • Valuelist pump operation fault - over speed
  • Valuelist electronic fault - supply current high
  • Valuelist electronic fault - supply current low
  • Valuelist auxiliary device fault - auxiliary medium insufficiency
  • Valuelist electronic fault - installation fault
  • Valuelist pump operation fault - motor overheat
  • Valuelist pump operation fault - operation fault
  • Valuelist electronic fault - short to earth
  • Valuelist electronic fault - supply current
  • net positive suction head required
  • pump NPSH curve
  • minimum allowable head
  • installation NPSH curve
  • optimum rate of flow
  • leakage rate of flow
  • minimum allowable thermal flow
  • maximum allowable head
  • Quick-acting speed
  • max. ambient temperature
  • Control types
  • Rotational direction of the pump
  • min. air humidity
  • Sound output level
  • markings
  • URL
  • product code
  • device class
  • asset ID
  • manufacturer URI
  • type of product
  • model
  • Counterpressure
  • balancing rate of flow
  • net positive suction head required for a drop of 3 %
  • location
  • day of construction
  • Coolant temperature
  • sound power
  • outlet temperature of the pump
  • design radial load
  • declaration of conformity
  • sound energy
  • sound energy level
  • sound energy
  • housing temperature
  • sound energy level
  • hydraulic efficiency
  • fluid temperature
  • Speed
  • Valuelist Controllable
  • Valuelist supported protocol
  • max. air humidity
  • min. temperature
  • min. ambient temperature during operation
  • sound pressure level
  • max. temperature
  • pump curve
  • pump efficiency curve
  • possible fluid
  • design axial load
  • pump power input curve
  • Valuelist device type
  • maximum axial load
  • maximum radial load
  • Valuelist auxiliary device fault - auxiliary power range
  • Valuelist hardware fault - power supply
  • Valuelist hardware fault - ram
  • Valuelist hardware fault - uP
  • Valuelist auxiliary device fault - corrosion
  • Valuelist auxiliary device fault - deviation
  • Valuelist auxiliary device fault - electromagnetic interference
  • Valuelist auxiliary device fault - auxiliary power pole
  • Valuelist auxiliary device fault - mechanical damage
  • Valuelist hardware fault - computing circuit
  • Valuelist auxiliary device fault - operating conditions
  • Valuelist hardware fault - control circuit
  • Valuelist hardware fault - eprom
  • Valuelist hardware fault - IONA
  • Valuelist hardware fault - measure circuit
  • Valuelist hardware fault - network NA
  • Valuelist electronic fault - supply voltage
  • Valuelist electronic fault - supply voltage high
  • Valuelist electronic fault - supply voltage low
  • Valuelist electronic fault - voltage inside device
  • corrective maintenance time
  • number of failures
  • severity
  • Valuelist electronic fault - winding temperature
  • Valuelist electronic fault - supply frequency high
  • Valuelist auxiliary device fault - exciter error
  • Valuelist electronic fault - supply frequency low
  • Valuelist auxiliary device fault - communication error
  • Valuelist auxiliary device fault - electronic fault
  • Valuelist auxiliary device fault - energy supply
  • Valuelist electronic fault - supply frequency
  • Valuelist auxiliary device fault - evaluation electronics
  • maintainability
  • operational reliability
  • production based availability
  • intrinsic reliability
  • time based availability
  • availability
  • durability
  • motor temperature
  • motor voltage
  • power factor
  • torque
  • total head at outlet area of the pump
  • mean rated velocity at outlet
  • DC link current
  • Valuelist auxiliary device fault - material electronics
  • Valuelist auxiliary device fault - measured material electronics
  • Valuelist auxiliary device fault - fouling
  • Valuelist auxiliary device fault - humidity electronics
  • Valuelist auxiliary device fault - overloading
  • Valuelist hardware fault - DC link supply
  • Valuelist auxiliary device fault - interruption
  • Valuelist auxiliary device fault - line length
  • expected reliability
  • instantaneous availability
  • Valuelist obsolescence
  • intrinsic maintainability
  • Valuelist auxiliary device fault - installation
  • Reliability according to norm
  • Valuelist pump operation fault - maximum operation time
  • Valuelist pump operation fault - dirty impeller
  • Valuelist pump operation fault - drive overheat
  • Valuelist pump operation fault - generator operation
  • Valuelist mechanical fault - radial bearing fault
  • Valuelist mechanical fault - excess vibration
  • Valuelist pump operation fault - lubricant
  • Valuelist pump operation fault - maximum number starts
  • Valuelist process fluid fault - cavitation
  • Valuelist process fluid fault - condensation
  • Valuelist software fault - OS
  • Valuelist software fault - parameter
  • Valuelist pump operation fault - leakage
  • Valuelist pump operation fault - coolant low
  • Valuelist pump operation fault - coolant overheat
  • Valuelist pump operation fault - deceleration
  • Valuelist pump operation fault - accessory liquid pressure
  • Valuelist pump operation fault - ambient temperature
  • Valuelist pump operation fault - case overheat
  • Valuelist mechanical fault - radial bearing overheat
  • Valuelist pump operation fault - coolant flow
  • Valuelist pump operation fault - coolant high
  • Valuelist hardware fault - communication
  • Valuelist pump operation fault - accessory liquid overheat
  • Valuelist pump operation fault - accessory liquid low
  • Valuelist mechanical fault - gap wear
  • Valuelist mechanical fault - misalignment
  • Valuelist mechanical fault - radial bearing abrasion
  • Valuelist mechanical fault - rotor blocked
  • Valuelist mechanical fault - rotor station rubbing
  • Valuelist pump operation fault - accessory liquid high
  • Valuelist mechanical fault - unbalance
  • Valuelist process fluid fault - viscosity
  • Valuelist mechanical fault - brake chopper
  • Valuelist process fluid fault - flow
  • Valuelist mechanical fault - brake overheat
  • Valuelist pump operation fault - accessory liquid flow
  • Valuelist process fluid fault - solid
  • Valuelist process fluid fault - stall
  • Valuelist process fluid fault - temperature
  • Valuelist mechanical fault - axial bearing fault
  • Valuelist mechanical fault - axial bearing overheat
  • Valuelist mechanical fault - bearing fault
  • Valuelist process fluid fault - dry
  • Valuelist process fluid fault - gas
  • Valuelist process fluid fault - liquid
  • Valuelist process fluid fault - pressure
  • Valuelist mechanical fault - axial bearing abrasion
  • Valuelist software fault - communication
  • Valuelist electronic fault - armature circuit
  • Valuelist software fault - control
  • Valuelist software fault - memory
  • Valuelist software fault - software reset
  • Valuelist process fluid fault - blockage
  • Valuelist software fault - application
  • Valuelist auxiliary device fault - wear reserve wear
  • Valuelist auxiliary device fault - parameter setting
  • Valuelist auxiliary device fault - peripheral
  • Valuelist auxiliary device fault - process influence
  • Valuelist auxiliary device fault - sensor element
  • Valuelist auxiliary device fault - start up
  • Valuelist auxiliary device fault - temperature shock
  • Valuelist auxiliary device fault - vibration
  • Valuelist auxiliary device fault - wear reserve operation
  • total head at outlet area of the installation
  • net positive suction head available
  • kinematic viscosity
  • mean rated velocity at inlet area of the installation
  • density
  • vapor pressure (gauge)
  • total head at inlet area of the installation
  • pump total head
  • Explosion protection Equipment Protection Level (EPL) of the pump
  • Explosion protection Equipment Protection Level (EPL) of the pump
  • Explosion protection explosion group of the electric motor
  • rated differential pressure
  • mean rated velocity at outlet area of the installation
  • height of the NPSH datum plane
  • installation total head
  • net positive inlet pressure required
  • valve spill velocity
  • mean repair time
  • standby time
  • Valuelist state of the item
  • failure rate
  • inlet area of the pump
  • volumetric efficiency
  • valve seat velocity
  • minimum allowable inlet pressure
  • Explosion protection device group of the pump
  • Explosion protection explosion group of the pump
  • Explosion protection Type of 'e' protection of the pump
  • Explosion protection code of the pump
  • Object identifier within a plant
  • Explosion protection category for devices, pump
  • Explosion protection temperature class of the pump
  • minimum allowable stable flow
  • useful life
  • overall efficiency
  • maximum dynamic sealing pressure
  • pump efficiency
  • pump mechanical power losses
  • pump rated power input
  • mechanical efficiency
  • Number of Pumps
  • exchange time difference
  • maximum number of pumps in operation
  • height of the outlet manometer
  • hydraulic efficiency
  • atmospheric pressure
  • height of the inlet manometer
  • voltage
  • DC link voltage
  • driver power input
  • current
  • energy consumption
  • frequency
  • motor current
  • pump best efficiency
  • category
  • Valuelist direction
  • ID carrier
  • down time
  • external disabled time
  • mean time to restauration
  • operating time
  • mean downtime
  • repair time
  • idle time
  • up time
  • Valuelist maintenance level
  • maintenance time
  • operating time between failures
  • operating time to failure
  • active maintenance time
  • time to restoration
  • Valuelist operation mode
  • pump collective Ids
  • Valuelist pump role
  • redundant pump Ids
  • exchange time
  • distribution priority
  • Valuelist distribution type
  • Valuelist exchange mode
  • pump kick time difference
  • Valuelist discrete input value
  • Valuelist pump kick mode
  • pump kick time