Classification: 36410501 [AAZ381022]

Preferred name 36-41-05-01 Axial piston pump
Keywords Nutating disk pump Swash plate pump
IRDI 0173-1#01-AAZ381#022
Already on the watchlist: 0 of max. 4

BASIC Properties: Axial piston pump

  • pump efficiency
  • pump best efficiency
  • pump rated power input
  • pump mechanical power losses
  • inlet area of the pump
  • overall efficiency
  • useful life
  • height of the inlet manometer
  • atmospheric pressure
  • height of the outlet manometer
  • hydraulic efficiency
  • maximum dynamic sealing pressure
  • minimum allowable stable flow
  • mechanical efficiency
  • ID carrier
  • redundant pump Ids
  • Valuelist direction
  • category
  • exchange time
  • maximum number of pumps in operation
  • exchange time difference
  • pump collective Ids
  • Valuelist pump role
  • distribution priority
  • Valuelist exchange mode
  • Valuelist distribution type
  • Valuelist pump operation fault - coolant flow
  • Valuelist pump operation fault - deceleration
  • Valuelist pump operation fault - coolant overheat
  • Valuelist pump operation fault - drive overheat
  • Valuelist operation mode
  • Number of Pumps
  • Valuelist pump operation fault - coolant high
  • Valuelist pump operation fault - lubricant
  • Valuelist pump operation fault - coolant low
  • Valuelist pump operation fault - maximum operation time
  • Valuelist pump operation fault - operation fault
  • Valuelist pump operation fault - dirty impeller
  • Valuelist pump operation fault - leakage
  • Valuelist pump operation fault - generator operation
  • Valuelist pump operation fault - maximum number starts
  • Valuelist pump operation fault - partial load
  • Valuelist pump operation fault - time out
  • Valuelist pump operation fault - temperature fault
  • Valuelist pump operation fault - motor humidity
  • Valuelist pump operation fault - motor overheat
  • Valuelist pump operation fault - over speed
  • Valuelist pump operation fault - over load
  • Valuelist pump operation fault - synchronisation
  • Valuelist process fluid fault - cavitation
  • Valuelist process fluid fault - dry
  • Valuelist mechanical fault - bearing fault
  • Valuelist mechanical fault - axial bearing overheat
  • Valuelist pump operation fault - maximum starts at time
  • Valuelist process fluid fault - blockage
  • Valuelist software fault - software reset
  • Valuelist process fluid fault - condensation
  • motor current
  • motor voltage
  • motor temperature
  • DC link voltage
  • frequency
  • energy consumption
  • sound power
  • leakage rate of flow
  • axial load of pump rotor
  • pump efficiency
  • lubricating oil consumption
  • level
  • mechanical efficiency
  • number of starts
  • radial load of pump rotor
  • clearance flow
  • pump temperature
  • hydraulic efficiency
  • bearing temperature
  • pump power output
  • axial rotor position
  • electronic temperature
  • overall efficiency
  • fluid temperature
  • sound energy level
  • housing temperature
  • sound energy
  • power loss due to internal leakage
  • next inspection date
  • last inspection date
  • next servicing date
  • last servicing date
  • Speed
  • outlet temperature of the pump
  • mean rated velocity at outlet
  • total head at outlet area of the pump
  • Min allowable inlet pressure
  • preventive maintenance time
  • active preventive maintenance time
  • installation date
  • kinematic viscosity
  • mean rated velocity at outlet area of the installation
  • Design differential pressure
  • mean rated velocity at inlet area of the installation
  • net positive suction head available
  • pump total head
  • installation total head
  • vapor pressure (gauge)
  • total head at outlet area of the installation
  • total head at inlet area of the installation
  • height of the NPSH datum plane
  • density
  • Explosion protection category for devices, pump
  • Object identifier within a plant
  • Explosion protection code of the pump
  • Explosion protection device group of the pump
  • Explosion protection Type of 'e' protection of the pump
  • Explosion protection explosion group of the pump
  • Valuelist pump kick mode
  • pump kick time difference
  • pump kick time
  • Explosion protection temperature class of the pump
  • Explosion protection explosion group of the electric motor
  • Explosion protection Equipment Protection Level (EPL) of the pump
  • Explosion protection Equipment Protection Level (EPL) of the pump
  • torque
  • power factor
  • DC link current
  • driver power input
  • Valuelist discrete input value
  • voltage
  • current
  • Relief valve set pressure
  • Relief valve overpressure
  • Relief valve locking pressure
  • Relief valve counter-pressure
  • Valuelist discrete output value
  • total head at inlet area of the pump
  • height of the inlet connection
  • height of the outlet connection
  • mean rated velocity at inlet
  • pump NPSH curve
  • net positive suction head required
  • maximum allowable head
  • net positive suction head required for a drop of 3 %
  • installation NPSH curve
  • minimum allowable head
  • minimum allowable thermal flow
  • leakage rate of flow
  • Coolant temperature
  • maximum radial load
  • maximum axial load
  • optimum rate of flow
  • balancing rate of flow
  • Counterpressure
  • sound energy level
  • sound energy
  • possible fluid
  • pump efficiency curve
  • sound power
  • declaration of conformity
  • design radial load
  • design axial load
  • Sound output level
  • Valuelist Controllable
  • Quick-acting speed
  • pump curve
  • Valuelist device type
  • pump power input curve
  • min. temperature
  • max. ambient temperature
  • max. air humidity
  • Control types
  • Rotational direction of the pump
  • min. ambient temperature during operation
  • max. temperature
  • sound pressure level
  • Valuelist supported protocol
  • Valuelist multi-phase
  • fluid
  • Valuelist operating mode
  • min. air humidity
  • volumetric efficiency
  • mean time to restauration
  • active maintenance time
  • operating time to failure
  • operating time between failures
  • mean repair time
  • maintenance time
  • Valuelist obsolescence
  • Valuelist state of the item
  • standby time
  • Valuelist maintenance level
  • up time
  • external disabled time
  • down time
  • repair time
  • failure rate
  • operating time
  • valve seat velocity
  • volumetric efficiency
  • idle time
  • time to restoration
  • mean downtime
  • total head at outlet area of the installation
  • total head at inlet area of the installation
  • net positive suction head
  • installation total head
  • valve spill velocity
  • Required net positive inlet pressure
  • Dynamic viscosity
  • lift circulating pump
  • kinematic viscosity
  • Installation inlet pressure
  • Instalation outlet pressure
  • Mass flow
  • differential pressure
  • motor efficiency
  • Min. nominal frequency
  • enclosure type no/class
  • Valuelist energy efficiency class (motor)
  • Nominal size of nozzle/pipe
  • Valuelist nominal pressure (PN) of the flange
  • norminal frequence
  • Nominal speed
  • nominal power consumption
  • nominal voltage
  • Max. nominal frequency
  • Power factor (cos phi)
  • minimum feed height
  • Min inlet pressure
  • Valuelist auxiliary device fault - parameter setting
  • Valuelist auxiliary device fault - sensor element
  • Valuelist auxiliary device fault - process influence
  • Valuelist auxiliary device fault - temperature shock
  • Valuelist software fault - control
  • Valuelist software fault - parameter
  • Valuelist software fault - OS
  • Valuelist auxiliary device fault - peripheral
  • Valuelist pump operation fault - wear reserve exhausted
  • Valuelist electronic fault - field circuit
  • Valuelist auxiliary device fault - auxiliary medium absence
  • Valuelist electronic fault - current inside device
  • Valuelist auxiliary device fault - start up
  • Valuelist pump operation fault - velocity limit
  • Valuelist pump operation fault - under speed
  • Valuelist auxiliary device fault - actuator element
  • Valuelist pump operation fault - TMS failure
  • Valuelist pump operation fault - turbine operation
  • Valuelist pump operation fault - torque limit
  • Valuelist electronic fault - short circuit
  • Valuelist auxiliary device fault - ambient temperature
  • Valuelist electronic fault - insulation resistance
  • Valuelist electronic fault - installation fault
  • Valuelist auxiliary device fault - auxiliary medium insufficiency
  • Valuelist electronic fault - supply current high
  • Valuelist auxiliary device fault - electromagnetic interference
  • Valuelist auxiliary device fault - deviation
  • Valuelist electronic fault - supply frequency
  • Valuelist electronic fault - phase failure
  • Valuelist electronic fault - supply current
  • Valuelist electronic fault - short to earth
  • Valuelist electronic fault - supply current low
  • Valuelist electronic fault - supply frequency high
  • Valuelist auxiliary device fault - evaluation electronics
  • Valuelist electronic fault - supply voltage high
  • Valuelist electronic fault - supply voltage
  • Valuelist auxiliary device fault - energy supply
  • Valuelist auxiliary device fault - electronic fault
  • Valuelist electronic fault - supply frequency low
  • Valuelist auxiliary device fault - exciter error
  • criticality
  • Valuelist failure
  • Min allowable outet pressure
  • Valuelist auxiliary device fault - auxiliary power range
  • Valuelist auxiliary device fault - auxiliary power pole
  • Valuelist auxiliary device fault - corrosion
  • Valuelist auxiliary device fault - communication error
  • availability
  • instantaneous availability
  • expected reliability
  • inlet temperature of the pump
  • durability
  • operational reliability
  • time based availability
  • Reliability according to norm
  • intrinsic reliability
  • intrinsic maintainability
  • maintainability
  • production based availability
  • Valuelist process fluid fault - pressure
  • Valuelist process fluid fault - liquid
  • Valuelist process fluid fault - stall
  • Valuelist process fluid fault - solid
  • Valuelist process fluid fault - gas
  • Valuelist mechanical fault - brake overheat
  • Valuelist process fluid fault - flow
  • Valuelist mechanical fault - brake chopper
  • Valuelist mechanical fault - axial bearing abrasion
  • Valuelist process fluid fault - viscosity
  • Valuelist process fluid fault - temperature
  • Valuelist pump operation fault - accessory liquid flow
  • corrective maintenance time
  • severity
  • number of failures
  • Valuelist mechanical fault - axial bearing fault
  • Valuelist pump operation fault - accessory liquid pressure
  • Valuelist pump operation fault - accessory liquid overheat
  • Valuelist hardware fault - communication
  • Valuelist pump operation fault - case overheat
  • Valuelist pump operation fault - accessory liquid low
  • Valuelist mechanical fault - unbalance
  • Valuelist pump operation fault - accessory liquid high
  • Valuelist mechanical fault - rotor station rubbing
  • Valuelist mechanical fault - misalignment
  • Valuelist mechanical fault - gap wear
  • Valuelist mechanical fault - radial bearing fault
  • Valuelist mechanical fault - radial bearing abrasion
  • Valuelist pump operation fault - ambient temperature
  • Valuelist pump operation fault - converter overheat
  • Valuelist pump operation fault - controller overheat
  • Valuelist mechanical fault - excess vibration
  • Valuelist electronic fault - winding temperature
  • Valuelist auxiliary device fault - measured material electronics
  • Valuelist auxiliary device fault - material electronics
  • Valuelist auxiliary device fault - operating conditions
  • Valuelist mechanical fault - rotor blocked
  • Valuelist mechanical fault - radial bearing overheat
  • Valuelist electronic fault - voltage inside device
  • Valuelist electronic fault - supply voltage low
  • Valuelist hardware fault - control circuit
  • Valuelist hardware fault - IONA
  • Valuelist hardware fault - eprom
  • Valuelist auxiliary device fault - fouling
  • Valuelist hardware fault - computing circuit
  • Valuelist auxiliary device fault - mechanical damage
  • Valuelist hardware fault - DC link supply
  • Valuelist auxiliary device fault - overloading
  • Valuelist hardware fault - network NA
  • Valuelist hardware fault - measure circuit
  • Valuelist hardware fault - ram
  • Valuelist hardware fault - power supply
  • Valuelist auxiliary device fault - installation
  • Valuelist auxiliary device fault - humidity electronics
  • Valuelist auxiliary device fault - line length
  • Valuelist auxiliary device fault - interruption
  • Valuelist software fault - communication
  • Valuelist auxiliary device fault - wear reserve wear
  • Valuelist software fault - application
  • Valuelist software fault - memory
  • Valuelist hardware fault - uP
  • Valuelist auxiliary device fault - wear reserve operation
  • Valuelist auxiliary device fault - vibration
  • Valuelist electronic fault - armature circuit
  • Min. permissible operating temperature at TS2, room2
  • Max. permissible operating temperature at TS1, room2
  • Max. permissible operating temperature at TS1, room1
  • Max. work temperature
  • material of housing
  • Rotational direction of the drive
  • Operation type time sequence of the drive
  • Load moment of the drive
  • Min. work temperature
  • Type of control
  • Type of elevation adjustment
  • material code of housing
  • Type of coating application, room 1
  • Valuelist Type of drive
  • Valuelist construction size
  • Valuelist Overflow valve integrated
  • country of manufacturer
  • Construction type of the connection, muff A1
  • description of class
  • Construction type of the connection, muff A2
  • proportional action coefficient
  • operating mode
  • control difference variable
  • command variable
  • National stock number
  • manipulated variable
  • integral action coefficient
  • controller output variable
  • Valuelist on/off
  • final controlled variable
  • feedback variable
  • reference variable
  • set control mode
  • controlled variable
  • derivative action coefficient
  • Manufacturer order code
  • Valuelist actual control mode
  • dead time
  • height of the outlet side of the installation
  • height of the pump
  • Valuelist Field bus system
  • solids volume fraction
  • height of the inlet side of the installation
  • required control mode
  • gas content
  • reference plane
  • min. temperature range
  • maximum ambient temperature (during operation)
  • minimum ambient temperature (during operation)
  • mean time between failures (MTBF)
  • working temperature
  • max. temperature range
  • Useful life
  • Valuelist actual operation mode
  • Valuelist enable
  • Valuelist control inversion
  • on off cycle
  • set operation mode
  • clearance volume
  • geometric displacement volume
  • slip flow
  • geometrical flow
  • Valuelist reverse rotating direction
  • Valuelist external signal
  • Pre-charge pressure
  • Valuelist fault action
  • Valuelist property-status
  • piston velocity
  • Stroke volume
  • fault value
  • initial operation date
  • component name
  • day of construction
  • location
  • asset ID
  • device class
  • product code
  • URL
  • month of construction
  • markings
  • model
  • type of product
  • manufacturer URI
  • software version
  • year of construction
  • hardware version
  • Valuelist Address of company representative
  • Max. permissible underpressure PS2- at TS2, room2
  • Max. permissible underpressure PS2- at TS2, room1
  • Max. permissible overpressure PS1+ at TS1, room1
  • Valuelist Construction form of the coupling
  • Max. permissible overpressure PS2+ at TS2, room1
  • Max. permissible underpressure PS1- at TS1, room2
  • Max. permissible underpressure PS1- at TS1, room1
  • Valuelist Sealing type
  • Valuelist Type of customs tariff number
  • Customs tariff number
  • HS-Code of the WCO
  • Valuelist Use of customs tariff number
  • Supplier product order suffix
  • Supplier product root
  • Supplier product family
  • Supplier product description
  • GLN of supplier
  • Supplier product type
  • URI of manufacturer
  • name of supplier
  • product article number of supplier
  • Supplier product designation
  • Manufacturer product family
  • Manufacturer product root
  • Manufacturer product order suffix
  • Brand
  • GLN of manufacturer
  • URI of the product
  • Product type
  • Manufacturer product designation
  • Manufacturer name
  • GTIN
  • Manufacturer product description
  • product article number of manufacturer
  • address of additional link
  • Valuelist Nominal pressure of the muffs, A2
  • design of dynamic seal
  • Code of the manufacturer declaration
  • Type description
  • Construction of the electric motor
  • Reference norm of the secondary sealing element material
  • Classification system of the electric motor
  • item list number of manufacturer
  • Valuelist Construction type
  • Explosion protection Type of 'e' protection of the electric motor
  • Classification system of the transmission
  • Class code of the electric motor
  • Material description of the valve ball/valve cone
  • Measurement tension of the electric motor
  • Material description of the secondary sealing element
  • Material number of the pump head
  • Product country of origin
  • Initial breakaway torque of the drive
  • Reference norm material of the drive housing
  • Explosion protection code of the electric motor
  • Reference norm of the explosion protection
  • Reference norm material of the valve ball/valve cone
  • Material description of the drive housing
  • Torque at nominal speed, drive
  • Material description of the pumping medium
  • empty weight
  • Class code of the transmission
  • Number of cylinders
  • Material number of the pumping medium
  • Measurement performance of the electric motor
  • Number of pump heads
  • Explosion protection temperature class of the electric motor
  • Reference norm of the connection, muff A2
  • Reference norm protection type of electric motor
  • Reference norm of the coating, room1
  • Year of construction
  • Material description of the valve face
  • Transmission ratio of the transmission
  • Construction of the connection, muff A1
  • Explosion protection category for devices , electric motor
  • Material number of the valve body
  • Valuelist guideline for conformity declaration
  • Reference norm of the valve body material
  • Max. feed flow
  • fabrication number
  • classification system
  • Shaft performance for nominal speed, drive
  • Material description of the coating, room1
  • Construction of the connection, muff A2
  • Material description of the membrane
  • code of class
  • reference standard
  • Protection type class of the electric motor
  • Reference norm of the connection, muff A1
  • Material description of the pump head
  • code of conformity evaluation
  • Reference norm material of the membrane
  • Setting pressure of the overflow valve
  • Max. permissible overpressure PS2+ at TS2, room2
  • Length over all, base plate
  • Valuelist Construction form of the seal surface, connection, muff A2
  • Valuelist Nominal pressure of the muffs, A1
  • Reference norm material of the displacement units
  • Min. feed flow
  • Moment of inertia of the drive
  • Min. permissible operating temperature at TS2, room1
  • over all height
  • overall length
  • Valuelist Heater/cooler present
  • Valuelist conformity declaration present
  • Valuelist Manufacturer declaration present
  • Valuelist Explosion protection certificate present
  • Construction form of the transmission
  • Construction form of the electric motor
  • overall width
  • Design temperature
  • Thickness of the coating, room1
  • Stroke length
  • Max. length of the stroke
  • External diameter of the displacement unit
  • normal feed flow
  • design
  • Measurement speed of the electric motor
  • Stroke rate piston
  • NPSH-nominal
  • minimum dynamic viscosity at design temperature
  • maximum dynamic viscosity at design temperature
  • Filling volume of the equipment
  • Max. speed of the drive
  • Max. number of strokes per minute for the piston
  • minimum density at design temperature
  • maximum density at design temperature
  • Min. number of strokes per minute for the piston
  • Nominal speed of the drive
  • Height over all, base plate
  • Min. speed of the drive
  • Max. permissible overpressure PS1+ at TS1, room2
  • Max. permissible pressure differential
  • Max. feed pressure, suction-side
  • Max. feed pressure suction-side
  • width over all, base plate
  • nominal feed height
  • Min. feed pressure, suction-side
  • maximum permissible counterpressure
  • Material number of the displacement units
  • Reference norm of the explosion protection of the electric motor
  • Valuelist Nominal width of the muffs, A1
  • Reference norm material of the coating, room1
  • Valuelist explosion protection marking
  • Material description of the displacement units
  • Material number of the secondary sealing element
  • supplier of the identifier
  • Material number of the coating, room1
  • drawing number of manufacturer
  • Valuelist Nominal width of the muffs, A2
  • Manufacturer's name of the sealing
  • Material number of the membrane
  • Construction of the transmission
  • Material number of the drive housing
  • Type of the seal
  • Explosion protection device group of the electric motor
  • Valuelist Construction form of the seal surface, connection, muff A1
  • Material number of the valve face
  • Reference norm material of the valve face
  • reference standard for material of the housing
  • Reference norm material of the pump head
  • Material description of the valve body
  • Material number of the valve ball, valve cone
X

We need your consent

This website uses necessary cookies to ensure the operation of the website. There is no analysis of user behavior by third parties. You can find detailed information about the use of cookies in our privacy policy.