Search the ECLASS content

ECLASS offers you the opportunity to have a look at and search the latest ECLASS Releases free of charge. The search function is intuitive and allows you to get to know the standard in a quick and non-bureaucratic manner.

How to use the ECLASS search

Please first select ...

  • whether you want to search ECLASS Basic or Advanced
  • in which Release version you want to search
  • in which language you want to search
  • whether you want to search in the classes or for properties, values etc.

Then enter a search term (e.g. "pencil") and click on "Search".
 

Please note that the application of the ECLASS Standard requires a license. (see also ECLASS Terms of Use)

eclass image

Classification: 36432290 [AKL910021]

Preferred name 36-43-22-90 Vacuum pump (rotating, unspecified)
Definition Sub-group (4th level) for objects that cannot be classified into other specified sub-groups in the existing structure, but that are classified to their parent-class on the 3rd level
Keywords Screw rotor vacuum pump Screw rotor vacuum compressor
IRDI 0173-1#01-AKL910#021
Already on the watchlist: 0 of max. 4

BASIC Properties: Vacuum pump (rotating, unspecified)

  • Valuelist auxiliary device fault - actuator element
  • Valuelist pump operation fault - wear reserve exhausted
  • Valuelist pump operation fault - velocity limit
  • Valuelist pump operation fault - under speed
  • Valuelist electronic fault - current inside device
  • Valuelist auxiliary device fault - ambient temperature
  • Valuelist electronic fault - field circuit
  • Valuelist auxiliary device fault - auxiliary medium absence
  • Valuelist auxiliary device fault - peripheral
  • Valuelist auxiliary device fault - parameter setting
  • Valuelist software fault - parameter
  • Valuelist software fault - OS
  • Valuelist auxiliary device fault - temperature shock
  • Valuelist auxiliary device fault - start up
  • Valuelist auxiliary device fault - sensor element
  • Valuelist auxiliary device fault - process influence
  • Valuelist electronic fault - armature circuit
  • Valuelist software fault - communication
  • Valuelist auxiliary device fault - wear reserve operation
  • Valuelist auxiliary device fault - vibration
  • Valuelist software fault - memory
  • Valuelist software fault - control
  • Valuelist auxiliary device fault - wear reserve wear
  • Valuelist software fault - application
  • Valuelist auxiliary device fault - interruption
  • Valuelist hardware fault - network NA
  • Valuelist auxiliary device fault - humidity electronics
  • Valuelist auxiliary device fault - line length
  • Valuelist hardware fault - power supply
  • Valuelist hardware fault - uP
  • Valuelist hardware fault - measure circuit
  • Valuelist hardware fault - ram
  • Valuelist auxiliary device fault - communication error
  • criticality
  • Valuelist auxiliary device fault - auxiliary power pole
  • Valuelist auxiliary device fault - corrosion
  • inlet temperature of the pump
  • Valuelist failure
  • Valuelist auxiliary device fault - exciter error
  • Valuelist electronic fault - supply frequency high
  • Valuelist auxiliary device fault - electronic fault
  • Valuelist electronic fault - supply frequency low
  • Valuelist electronic fault - supply voltage
  • Valuelist auxiliary device fault - auxiliary power range
  • Valuelist auxiliary device fault - evaluation electronics
  • Valuelist electronic fault - supply voltage high
  • Valuelist electronic fault - supply current low
  • Valuelist electronic fault - supply current high
  • Valuelist electronic fault - supply current
  • Valuelist electronic fault - short to earth
  • Valuelist electronic fault - supply frequency
  • Valuelist auxiliary device fault - energy supply
  • Valuelist auxiliary device fault - electromagnetic interference
  • Valuelist auxiliary device fault - deviation
  • Valuelist auxiliary device fault - auxiliary medium insufficiency
  • Valuelist pump operation fault - TMS failure
  • Valuelist electronic fault - insulation resistance
  • Valuelist electronic fault - installation fault
  • Valuelist electronic fault - short circuit
  • Valuelist electronic fault - phase failure
  • Valuelist pump operation fault - turbine operation
  • Valuelist pump operation fault - torque limit
  • Valuelist mechanical fault - axial bearing fault
  • Valuelist mechanical fault - axial bearing abrasion
  • severity
  • number of failures
  • Valuelist pump operation fault - accessory liquid flow
  • Valuelist pump operation fault - accessory liquid low
  • Valuelist process fluid fault - viscosity
  • Valuelist process fluid fault - temperature
  • Valuelist mechanical fault - brake chopper
  • Valuelist process fluid fault - pressure
  • Valuelist mechanical fault - brake overheat
  • Valuelist process fluid fault - flow
  • Valuelist process fluid fault - solid
  • corrective maintenance time
  • Valuelist process fluid fault - liquid
  • Valuelist process fluid fault - stall
  • Valuelist process fluid fault - condensation
  • Valuelist process fluid fault - cavitation
  • Valuelist process fluid fault - blockage
  • Valuelist software fault - software reset
  • Valuelist mechanical fault - axial bearing overheat
  • Valuelist process fluid fault - gas
  • Valuelist process fluid fault - dry
  • Valuelist mechanical fault - bearing fault
  • Valuelist pump operation fault - synchronisation
  • Valuelist pump operation fault - partial load
  • Valuelist pump operation fault - over speed
  • Valuelist pump operation fault - over load
  • Valuelist pump operation fault - motor humidity
  • Valuelist pump operation fault - maximum starts at time
  • Valuelist pump operation fault - time out
  • Valuelist pump operation fault - temperature fault
  • Valuelist auxiliary device fault - overloading
  • Valuelist hardware fault - control circuit
  • Valuelist auxiliary device fault - mechanical damage
  • Valuelist hardware fault - DC link supply
  • Valuelist auxiliary device fault - fouling
  • Valuelist auxiliary device fault - installation
  • Valuelist hardware fault - IONA
  • Valuelist hardware fault - eprom
  • Valuelist electronic fault - supply voltage low
  • Valuelist electronic fault - winding temperature
  • Valuelist mechanical fault - radial bearing overheat
  • Valuelist electronic fault - voltage inside device
  • Valuelist auxiliary device fault - operating conditions
  • Valuelist hardware fault - computing circuit
  • Valuelist auxiliary device fault - measured material electronics
  • Valuelist auxiliary device fault - material electronics
  • Valuelist mechanical fault - excess vibration
  • Valuelist mechanical fault - misalignment
  • Valuelist pump operation fault - converter overheat
  • Valuelist pump operation fault - controller overheat
  • Valuelist mechanical fault - radial bearing abrasion
  • Valuelist mechanical fault - rotor blocked
  • Valuelist mechanical fault - gap wear
  • Valuelist mechanical fault - radial bearing fault
  • Valuelist mechanical fault - rotor station rubbing
  • Valuelist pump operation fault - accessory liquid pressure
  • Valuelist mechanical fault - unbalance
  • Valuelist pump operation fault - accessory liquid high
  • Valuelist pump operation fault - case overheat
  • Valuelist pump operation fault - ambient temperature
  • Valuelist pump operation fault - accessory liquid overheat
  • Valuelist hardware fault - communication
  • mechanical efficiency
  • height of the inlet manometer
  • maximum dynamic sealing pressure
  • minimum allowable stable flow
  • Max. feed flow
  • Min. feed flow
  • atmospheric pressure
  • height of the outlet manometer
  • useful life
  • pump efficiency
  • overall efficiency
  • pump mechanical power losses
  • hydraulic efficiency
  • pump best efficiency
  • pump rated power input
  • last servicing date
  • preventive maintenance time
  • last inspection date
  • next servicing date
  • inlet area of the pump
  • active preventive maintenance time
  • installation date
  • fluid temperature
  • Speed
  • next inspection date
  • outlet temperature of the pump
  • Valuelist pump operation fault - maximum number starts
  • Valuelist pump operation fault - lubricant
  • Valuelist pump operation fault - leakage
  • Valuelist pump operation fault - generator operation
  • Valuelist pump operation fault - operation fault
  • Valuelist pump operation fault - motor overheat
  • Valuelist pump operation fault - coolant low
  • Valuelist pump operation fault - maximum operation time
  • Valuelist pump operation fault - coolant high
  • Valuelist pump operation fault - coolant flow
  • Number of Pumps
  • Valuelist pump operation fault - drive overheat
  • Valuelist pump operation fault - dirty impeller
  • Valuelist pump operation fault - deceleration
  • Valuelist pump operation fault - coolant overheat
  • Valuelist distribution type
  • exchange time
  • distribution priority
  • Valuelist exchange mode
  • pump collective Ids
  • Valuelist operation mode
  • maximum number of pumps in operation
  • exchange time difference
  • category
  • ID carrier
  • Valuelist direction
  • redundant pump Ids
  • Valuelist pump role
  • Inlet pressure
  • Pre-vacuum pressure
  • current
  • torque
  • voltage
  • Valuelist pump kick mode
  • Valuelist discrete input value
  • pump kick time difference
  • pump kick time
  • hydraulic efficiency
  • sound energy level
  • clearance flow
  • pump temperature
  • power loss due to internal leakage
  • overall efficiency
  • housing temperature
  • sound energy
  • pump efficiency
  • bearing temperature
  • leakage rate of flow
  • axial load of pump rotor
  • electronic temperature
  • radial load of pump rotor
  • pump power output
  • axial rotor position
  • lubricating oil consumption
  • motor voltage
  • motor temperature
  • number of starts
  • sound power
  • level
  • mechanical efficiency
  • driver power input
  • DC link voltage
  • power factor
  • DC link current
  • motor current
  • frequency
  • energy consumption
  • Max. permissible operating temperature at TS1, room1
  • Temperature at the inlet
  • Min. permissible operating temperature at TS2, room2
  • Max. permissible operating temperature at TS1, room2
  • Manufacturer order code
  • Construction form of the dynamic seal, shaft
  • Construction form of the transmission
  • Thickness of the coating, room1
  • Thickness of the coating, travel wheel
  • Design temperature
  • Filling volume of the equipment
  • Construction form of the electric motor
  • overall width
  • description of class
  • Moment of inertia of the drive
  • Valuelist Manufacturer declaration present
  • Valuelist Explosion protection certificate present
  • Min. permissible operating temperature at TS2, room1
  • thickness of coating (external surface)
  • over all height
  • overall length
  • Construction type of the connection, muff A1
  • Construction type of the connection, muff A2
  • Load moment of the drive
  • country of manufacturer
  • Valuelist construction size
  • Valuelist conformity declaration present
  • Type of coating application, room 1
  • Type of coating application, external surface
  • material of housing
  • Operating type feed of the operating medium
  • Temperature differential overall
  • material code of housing
  • Rotational direction of the drive
  • Operation type time sequence of the drive
  • Type of coating application, travel wheel
  • Type of set-up
  • component name
  • day of construction
  • asset ID
  • initial operation date
  • model
  • type of product
  • location
  • markings
  • Valuelist property-status
  • fault value
  • Valuelist fault action
  • Valuelist enable
  • set operation mode
  • Valuelist actual operation mode
  • Valuelist external signal
  • Valuelist control inversion
  • Valuelist reverse rotating direction
  • volume flow rate
  • Base pressure
  • standard gas flowrate
  • maximum allowable throughput
  • warm-up time for a vapour jet pump or a diffusion pump
  • volume flow rate of backing pump
  • Valuelist on/off
  • final controlled variable
  • derivative action coefficient
  • controller output variable
  • dead time
  • feedback variable
  • Valuelist actual control mode
  • operating mode
  • control difference variable
  • integral action coefficient
  • proportional action coefficient
  • set control mode
  • controlled variable
  • command variable
  • reference variable
  • Valuelist Address of company representative
  • manipulated variable
  • software version
  • National stock number
  • product code
  • URL
  • manufacturer URI
  • device class
  • hardware version
  • month of construction
  • year of construction
  • max. temperature
  • sound pressure level
  • min. ambient temperature during operation
  • max. air humidity
  • Control types
  • Valuelist supported protocol
  • max. ambient temperature
  • Valuelist device type
  • pump power input curve
  • pump efficiency curve
  • pump curve
  • Valuelist Controllable
  • Quick-acting speed
  • min. temperature
  • Sound output level
  • declaration of conformity
  • design radial load
  • maximum axial load
  • sound power
  • sound energy
  • possible fluid
  • design axial load
  • sound energy level
  • height of the inlet connection
  • height of the outlet connection
  • maximum radial load
  • Coolant temperature
  • on off cycle
  • maximum ambient temperature (during operation)
  • minimum ambient temperature (during operation)
  • cool-down time for a vapour jet pump or a diffusion pump
  • Starting pressure
  • water vapour tolerable load
  • solids volume fraction
  • mean time between failures (MTBF)
  • height of the pump
  • Valuelist Field bus system
  • Useful life
  • min. temperature range
  • working temperature
  • max. temperature range
  • Valuelist operating mode
  • height of the inlet side of the installation
  • Valuelist multi-phase
  • fluid
  • reference plane
  • height of the outlet side of the installation
  • required control mode
  • gas content
  • Rotational direction of the pump
  • min. air humidity
  • throughput
  • Process pressure
  • pump humidity
  • standby time
  • Valuelist maintenance level
  • failure rate
  • Valuelist state of the item
  • time to restoration
  • up time
  • idle time
  • active maintenance time
  • operating time to failure
  • Valuelist obsolescence
  • mean time to restauration
  • down time
  • repair time
  • operating time between failures
  • external disabled time
  • time based availability
  • Reliability according to norm
  • production based availability
  • operational reliability
  • mean repair time
  • maintenance time
  • instantaneous availability
  • durability
  • availability
  • intrinsic maintainability
  • maintainability
  • expected reliability
  • intrinsic reliability
  • nominal power consumption
  • norminal frequence
  • Nominal speed
  • Valuelist discrete output value
  • enclosure type no/class
  • Valuelist energy efficiency class (motor)
  • motor efficiency
  • Min. nominal frequency
  • Power factor (cos phi)
  • nominal voltage
  • Max. nominal frequency
  • compression ratio
  • throughput
  • Nominal size of nozzle/pipe
  • Valuelist nominal pressure (PN) of the flange
  • Nominal pressure
  • Critical pre-vacuum pressure
  • mean downtime
  • operating time
  • water vapour capacity
  • Max tolerable water vapour inlet pressure
  • Max working pressure
  • Manufacturer product family
  • Manufacturer product root
  • Product type
  • Manufacturer product designation
  • Manufacturer product description
  • Manufacturer product order suffix
  • Brand
  • product article number of supplier
  • Supplier product designation
  • GLN of manufacturer
  • URI of the product
  • URI of manufacturer
  • Supplier product order suffix
  • Supplier product root
  • GLN of supplier
  • Supplier product type
  • name of supplier
  • Supplier product family
  • Supplier product description
  • Valuelist Type of customs tariff number
  • Customs tariff number
  • HS-Code of the WCO
  • Valuelist Use of customs tariff number
  • address of additional link
  • Manufacturer name
  • product article number of manufacturer
  • GTIN
  • Valuelist Material number of the static seal, housing
  • Material description of the shaft protection sleeve
  • Shaft performance for nominal speed, drive
  • Material description of the travel wheel
  • Nominal width of the suction supports
  • Protection type class of the electric motor
  • Material description of the coating, room1
  • Valuelist guideline for conformity declaration
  • Material description of the design
  • Reference norm protection type of electric motor
  • Reference norm of the connection, muff A2
  • Construction of the shaft end, drive
  • fabrication number
  • classification system
  • Reference norm of the coating, room1
  • Year of construction
  • Class code of the transmission
  • Material number of the conveying element
  • reference standard for the coating (external surface)
  • Valuelist Material number of the shaft
  • Reference norm material of the static seal, housing
  • Explosion protection category for devices , electric motor
  • Transmission ratio of the transmission
  • Construction of the connection, muff A1
  • Material description of the conveying element
  • Material description of the static seal, housing
  • Measurement performance of the electric motor
  • Material number of the shaft protective sleeve
  • Explosion protection temperature class of the electric motor
  • empty weight
  • Material number of the coating, travel wheel
  • Construction of the dynamic seal, shaft
  • minimum permissible counterpressure
  • Max. permissible overpressure PS1+ at TS1, room1
  • Max. permissible underpressure PS2- at TS2, room1
  • Counterpressure
  • Max. overpressure of the shaft seal
  • Valuelist Construction form of the coupling
  • Max. permissible overpressure PS2+ at TS2, room2
  • Max. permissible overpressure PS2+ at TS2, room1
  • Pressure suction-side
  • Max. pressure differential
  • Valuelist Sealing type
  • Max. permissible underpressure PS2- at TS2, room2
  • Max. permissible underpressure PS1- at TS1, room2
  • Max. permissible underpressure PS1- at TS1, room1
  • Valuelist Construction form of the seal surface, connection, muff A2
  • Valuelist Nominal pressure of the muffs, A1
  • code of class
  • reference standard
  • Max. permissible overpressure PS1+ at TS1, room2
  • Valuelist explosion protection marking
  • reference standard for material of the coating (external surface)
  • Valuelist Material number of the travel wheel
  • Reference norm of the connection, muff A1
  • Material key of the dynamic seal, shaft
  • Material number of the dynamic seal, shaft
  • Nominal volume flow of the suction side
  • Construction of the connection, muff A2
  • Type description of the sealing
  • code of conformity evaluation
  • material of coating (external surface)
  • Manufacturer's name of the sealing
  • Suction capacity
  • Valuelist Nominal width of the muffs, A2
  • Reference norm of the dynamic seal, shaft
  • Explosion protection device group of the electric motor
  • Valuelist Construction form of the seal surface, connection, muff A1
  • reference standard for material of the housing
  • Material number of the design
  • Construction of the transmission
  • Material number of the drive housing
  • Valuelist Nominal width of the muffs, A1
  • Reference norm material of the coating, room1
  • Material number of the coating, room1
  • drawing number of manufacturer
  • Material description of the shaft
  • Valuelist material code of coating (external surface)
  • Reference norm material of the coating, travel wheel
  • Construction of the static seal, housing
  • minimum density at design temperature
  • maximum density at design temperature
  • Nominal width of the press supports
  • Reference norm of the explosion protection of the electric motor
  • Material description of the coating, travel wheel
  • supplier of the identifier
  • design
  • Measurement speed of the electric motor
  • Construction type conveying element
  • Ratio of the specific heat capacities
  • Max. speed of the drive
  • Rotation speed pump
  • Nominal speed of the drive
  • Min. speed of the drive
  • Torque at nominal speed, drive
  • Product country of origin
  • Reference norm material, design
  • Reference norm of the static seal, housing
  • Reference norm material of the travel wheel
  • Explosion protection code of the electric motor
  • Initial breakaway torque of the drive
  • Reference norm material of the drive housing
  • Classification system of the transmission
  • Class code of the electric motor
  • Material description of the can
  • Explosion protection Type of 'e' protection of the electric motor
  • Material description of the drive housing
  • Material number of the can
  • Reference norm of the explosion protection
  • Reference norm material of the shaft protection sleeve
  • Measurement tension of the electric motor
  • Reference norm of the conveying element material
  • Type description
  • Material number of the operating liquid
  • Material description of the operating liquid
  • Valuelist Construction type
  • Reference norm of the shaft end, drive
  • Reference norm of the can material
  • Classification system of the electric motor
  • Reference norm of the coating, travel wheel
  • Construction of the electric motor
  • Material description of the dynamic seal, shaft
  • Reference norm material of the shaft
  • Code of the manufacturer declaration
  • item list number of manufacturer
  • Valuelist Nominal pressure of the muffs, A2
X

We need your consent

This website uses necessary cookies to ensure the operation of the website. There is no analysis of user behavior by third parties. You can find detailed information about the use of cookies in our privacy policy.