Search the ECLASS content

ECLASS offers you the opportunity to have a look at and search the latest ECLASS Releases free of charge. The search function is intuitive and allows you to get to know the standard in a quick and non-bureaucratic manner.

How to use the ECLASS search

Please first select ...

  • whether you want to search ECLASS Basic or Advanced
  • in which Release version you want to search
  • in which language you want to search
  • whether you want to search in the classes or for properties, values etc.

Then enter a search term (e.g. "pencil") and click on "Search".
 

Please note that the application of the ECLASS Standard requires a license. (see also ECLASS Terms of Use)

eclass image

Classification: 36432402 [AKL918018]

Preferred name 36-43-24-02 Turbomolecular pump (axial flow)
IRDI 0173-1#01-AKL918#018
Already on the watchlist: 0 of max. 4

BASIC Properties: Turbomolecular pump (axial flow)

  • Valuelist pump kick mode
  • pump kick time
  • pump kick time difference
  • Valuelist direction
  • inlet area of the pump
  • pump collective Ids
  • Valuelist pump role
  • Valuelist distribution type
  • redundant pump Ids
  • exchange time difference
  • maximum number of pumps in operation
  • Valuelist operation mode
  • exchange time
  • distribution priority
  • Number of Pumps
  • Valuelist exchange mode
  • Base pressure
  • volume flow rate
  • volume flow rate of backing pump
  • Valuelist property-status
  • Valuelist discrete input value
  • pump efficiency
  • pump mechanical power losses
  • maximum dynamic sealing pressure
  • height of the outlet manometer
  • useful life
  • mechanical efficiency
  • atmospheric pressure
  • pump rated power input
  • hydraulic efficiency
  • height of the inlet manometer
  • Min. feed flow
  • ID carrier
  • category
  • pump best efficiency
  • minimum allowable stable flow
  • Max. feed flow
  • overall efficiency
  • Valuelist software fault - parameter
  • Valuelist software fault - software reset
  • Valuelist process fluid fault - blockage
  • Valuelist process fluid fault - cavitation
  • Valuelist software fault - communication
  • Valuelist electronic fault - armature circuit
  • Valuelist software fault - memory
  • Valuelist software fault - OS
  • Valuelist auxiliary device fault - interruption
  • Valuelist auxiliary device fault - fouling
  • Valuelist auxiliary device fault - material electronics
  • Valuelist auxiliary device fault - installation
  • Valuelist hardware fault - ram
  • Valuelist hardware fault - uP
  • Valuelist auxiliary device fault - humidity electronics
  • Valuelist auxiliary device fault - parameter setting
  • Valuelist auxiliary device fault - operating conditions
  • Valuelist hardware fault - control circuit
  • Valuelist hardware fault - eprom
  • Valuelist hardware fault - computing circuit
  • Valuelist auxiliary device fault - mechanical damage
  • Valuelist auxiliary device fault - line length
  • Valuelist auxiliary device fault - overloading
  • Valuelist auxiliary device fault - measured material electronics
  • Valuelist mechanical fault - radial bearing abrasion
  • Valuelist hardware fault - network NA
  • Valuelist mechanical fault - radial bearing overheat
  • Valuelist mechanical fault - misalignment
  • Valuelist hardware fault - measure circuit
  • Valuelist hardware fault - DC link supply
  • Valuelist hardware fault - power supply
  • Valuelist hardware fault - IONA
  • radial load of pump rotor
  • electronic temperature
  • sound energy level
  • hydraulic efficiency
  • pump power output
  • bearing temperature
  • sound energy
  • housing temperature
  • number of starts
  • mechanical efficiency
  • Sound output level
  • sound pressure level
  • level
  • sound power
  • lubricating oil consumption
  • leakage rate of flow
  • Valuelist process fluid fault - condensation
  • Valuelist auxiliary device fault - peripheral
  • Valuelist auxiliary device fault - process influence
  • fluid temperature
  • Speed
  • outlet temperature of the pump
  • Valuelist software fault - application
  • Valuelist auxiliary device fault - wear reserve wear
  • Valuelist software fault - control
  • Valuelist auxiliary device fault - wear reserve operation
  • Valuelist auxiliary device fault - sensor element
  • Valuelist auxiliary device fault - start up
  • Valuelist auxiliary device fault - temperature shock
  • Valuelist auxiliary device fault - vibration
  • mean time between failures (MTBF)
  • Critical pre-vacuum pressure
  • water vapour capacity
  • external disabled time
  • operating time to failure
  • operating time
  • mean downtime
  • time based availability
  • maintainability
  • availability
  • production based availability
  • Max working pressure
  • Max tolerable water vapour inlet pressure
  • operational reliability
  • intrinsic reliability
  • instantaneous availability
  • Reliability according to norm
  • durability
  • expected reliability
  • Valuelist obsolescence
  • intrinsic maintainability
  • pump efficiency
  • axial load of pump rotor
  • pump temperature
  • clearance flow
  • overall efficiency
  • axial rotor position
  • power loss due to internal leakage
  • max. air humidity
  • Quick-acting speed
  • min. air humidity
  • Valuelist supported protocol
  • max. ambient temperature
  • min. ambient temperature during operation
  • Process pressure
  • pump humidity
  • throughput
  • Valuelist Controllable
  • min. temperature
  • Valuelist conformity declaration present
  • Rotational direction of the pump
  • Valuelist state of the item
  • failure rate
  • Valuelist maintenance level
  • maintenance time
  • standby time
  • time to restoration
  • idle time
  • down time
  • active maintenance time
  • repair time
  • mean time to restauration
  • up time
  • operating time between failures
  • mean repair time
  • fault value
  • height of the outlet connection
  • on off cycle
  • Valuelist discrete output value
  • Valuelist fault action
  • Pre-vacuum pressure
  • Inlet pressure
  • Nominal size of nozzle/pipe
  • height of the inlet connection
  • Valuelist device type
  • maximum axial load
  • sound energy
  • maximum radial load
  • pump curve
  • possible fluid
  • pump power input curve
  • pump efficiency curve
  • Control types
  • design radial load
  • Valuelist guideline for conformity declaration
  • max. temperature
  • sound energy level
  • sound power
  • declaration of conformity
  • design axial load
  • nominal power consumption
  • Nominal speed
  • throughput
  • Torque at nominal speed, drive
  • norminal frequence
  • enclosure type no/class
  • Power factor (cos phi)
  • height of the pump
  • Valuelist operating mode
  • Valuelist multi-phase
  • Nominal pressure
  • compression ratio
  • Valuelist nominal pressure (PN) of the flange
  • required control mode
  • height of the inlet side of the installation
  • working temperature
  • min. temperature range
  • reference plane
  • gas content
  • height of the outlet side of the installation
  • fluid
  • max. temperature range
  • Valuelist Field bus system
  • maximum ambient temperature (during operation)
  • Useful life
  • minimum ambient temperature (during operation)
  • solids volume fraction
  • National stock number
  • software version
  • hardware version
  • Valuelist Address of company representative
  • fabrication number
  • asset ID
  • Manufacturer order code
  • control difference variable
  • proportional action coefficient
  • controller output variable
  • set control mode
  • reference variable
  • command variable
  • integral action coefficient
  • derivative action coefficient
  • operating mode
  • final controlled variable
  • controlled variable
  • Valuelist on/off
  • Valuelist actual control mode
  • feedback variable
  • Max. nominal frequency
  • Min. nominal frequency
  • nominal voltage
  • Valuelist energy efficiency class (motor)
  • dead time
  • manipulated variable
  • Starting pressure
  • maximum allowable throughput
  • Valuelist reverse rotating direction
  • warm-up time for a vapour jet pump or a diffusion pump
  • water vapour tolerable load
  • cool-down time for a vapour jet pump or a diffusion pump
  • standard gas flowrate
  • Valuelist external signal
  • Valuelist actual operation mode
  • Valuelist enable
  • set operation mode
  • Valuelist control inversion
  • manufacturer URI
  • type of product
  • product code
  • day of construction
  • Counterpressure
  • Coolant temperature
  • location
  • initial operation date
  • device class
  • component name
  • month of construction
  • markings
  • URL
  • year of construction
  • model
  • address of additional link
  • name of supplier
  • Supplier product designation
  • product article number of supplier
  • Supplier product root
  • Supplier product order suffix
  • Supplier product description
  • Supplier product family
  • URI of the product
  • GLN of manufacturer
  • Manufacturer product designation
  • Product type
  • URI of manufacturer
  • Manufacturer product description
  • product article number of manufacturer
  • Manufacturer product root
  • Manufacturer product family
  • Brand
  • Manufacturer product order suffix
  • Manufacturer name
  • GTIN
  • Valuelist Use of customs tariff number
  • HS-Code of the WCO
  • Supplier product type
  • GLN of supplier
  • Customs tariff number
  • Valuelist Type of customs tariff number
  • last servicing date
  • installation date
  • preventive maintenance time
  • next inspection date
  • inlet temperature of the pump
  • last inspection date
  • energy consumption
  • voltage
  • motor current
  • driver power input
  • active preventive maintenance time
  • next servicing date
  • DC link voltage
  • DC link current
  • motor voltage
  • torque
  • current
  • motor temperature
  • frequency
  • power factor
  • motor efficiency
  • Valuelist auxiliary device fault - exciter error
  • Valuelist electronic fault - supply frequency low
  • Valuelist electronic fault - supply voltage high
  • Valuelist electronic fault - supply voltage low
  • Valuelist electronic fault - supply frequency
  • Valuelist auxiliary device fault - evaluation electronics
  • Valuelist electronic fault - supply voltage
  • Valuelist auxiliary device fault - energy supply
  • Valuelist pump operation fault - torque limit
  • Valuelist electronic fault - supply current low
  • Valuelist pump operation fault - under speed
  • Valuelist pump operation fault - TMS failure
  • Valuelist electronic fault - voltage inside device
  • Valuelist electronic fault - winding temperature
  • Valuelist electronic fault - supply current
  • Valuelist electronic fault - supply current high
  • Valuelist auxiliary device fault - actuator element
  • Valuelist auxiliary device fault - ambient temperature
  • Valuelist auxiliary device fault - auxiliary medium insufficiency
  • Valuelist electronic fault - installation fault
  • Valuelist pump operation fault - wear reserve exhausted
  • Valuelist pump operation fault - turbine operation
  • Valuelist electronic fault - current inside device
  • Valuelist pump operation fault - velocity limit
  • Valuelist electronic fault - short circuit
  • Valuelist electronic fault - short to earth
  • Valuelist failure
  • criticality
  • Valuelist auxiliary device fault - auxiliary medium absence
  • Valuelist electronic fault - field circuit
  • Valuelist electronic fault - insulation resistance
  • Valuelist electronic fault - phase failure
  • Valuelist pump operation fault - motor overheat
  • Valuelist pump operation fault - maximum starts at time
  • Valuelist pump operation fault - over load
  • Valuelist pump operation fault - motor humidity
  • Valuelist process fluid fault - stall
  • Valuelist process fluid fault - temperature
  • Valuelist process fluid fault - viscosity
  • Valuelist pump operation fault - accessory liquid flow
  • Valuelist pump operation fault - time out
  • Valuelist pump operation fault - synchronisation
  • Valuelist pump operation fault - coolant low
  • Valuelist pump operation fault - coolant overheat
  • Valuelist pump operation fault - partial load
  • Valuelist pump operation fault - operation fault
  • Valuelist pump operation fault - temperature fault
  • Valuelist pump operation fault - over speed
  • Valuelist pump operation fault - leakage
  • Valuelist pump operation fault - lubricant
  • Valuelist pump operation fault - maximum number starts
  • Valuelist pump operation fault - maximum operation time
  • Valuelist pump operation fault - deceleration
  • Valuelist pump operation fault - dirty impeller
  • Valuelist pump operation fault - drive overheat
  • Valuelist pump operation fault - generator operation
  • Valuelist auxiliary device fault - electronic fault
  • Valuelist auxiliary device fault - corrosion
  • Valuelist electronic fault - supply frequency high
  • Valuelist auxiliary device fault - electromagnetic interference
  • Valuelist auxiliary device fault - communication error
  • Valuelist auxiliary device fault - auxiliary power pole
  • Valuelist auxiliary device fault - deviation
  • Valuelist auxiliary device fault - auxiliary power range
  • Valuelist hardware fault - communication
  • Valuelist pump operation fault - accessory liquid overheat
  • Valuelist mechanical fault - unbalance
  • Valuelist pump operation fault - accessory liquid low
  • Valuelist pump operation fault - accessory liquid high
  • Valuelist mechanical fault - radial bearing fault
  • Valuelist mechanical fault - rotor blocked
  • Valuelist mechanical fault - rotor station rubbing
  • Valuelist pump operation fault - converter overheat
  • Valuelist pump operation fault - coolant flow
  • Valuelist mechanical fault - gap wear
  • Valuelist pump operation fault - coolant high
  • Valuelist pump operation fault - accessory liquid pressure
  • Valuelist pump operation fault - ambient temperature
  • Valuelist pump operation fault - case overheat
  • Valuelist pump operation fault - controller overheat
  • Valuelist mechanical fault - axial bearing overheat
  • severity
  • Valuelist process fluid fault - flow
  • Valuelist mechanical fault - axial bearing fault
  • number of failures
  • Valuelist mechanical fault - excess vibration
  • Valuelist mechanical fault - axial bearing abrasion
  • corrective maintenance time
  • Valuelist mechanical fault - brake overheat
  • Valuelist process fluid fault - gas
  • Valuelist process fluid fault - pressure
  • Valuelist process fluid fault - solid
  • Valuelist process fluid fault - dry
  • Valuelist mechanical fault - brake chopper
  • Valuelist process fluid fault - liquid
  • Valuelist mechanical fault - bearing fault
X

We need your consent

This website uses necessary cookies to ensure the operation of the website. There is no analysis of user behavior by third parties. You can find detailed information about the use of cookies in our privacy policy.