Search the ECLASS content

ECLASS offers you the opportunity to have a look at and search the latest ECLASS Releases free of charge. The search function is intuitive and allows you to get to know the standard in a quick and non-bureaucratic manner.

How to use the ECLASS search

Please first select ...

  • whether you want to search ECLASS Basic or Advanced
  • in which Release version you want to search
  • in which language you want to search
  • whether you want to search in the classes or for properties, values etc.

Then enter a search term (e.g. "pencil") and click on "Search".
 

Please note that the application of the ECLASS Standard requires a license. (see also ECLASS Terms of Use)

eclass image

Classification: 36432590 [AKL924018]

Preferred name 36-43-25-90 Vacuum pump (special execution, unspecified)
Definition Sub-group (4th level) for objects that cannot be classified into other specified sub-groups in the existing structure, but that are classified to their parent-class on the 3rd level
IRDI 0173-1#01-AKL924#018
Already on the watchlist: 0 of max. 4

BASIC Properties: Vacuum pump (special execution, unspecified)

  • asset ID
  • initial operation date
  • location
  • markings
  • component name
  • day of construction
  • manufacturer URI
  • device class
  • model
  • type of product
  • month of construction
  • year of construction
  • product code
  • URL
  • set operation mode
  • Valuelist actual operation mode
  • Valuelist control inversion
  • Valuelist reverse rotating direction
  • Valuelist enable
  • fault value
  • Valuelist fault action
  • Valuelist external signal
  • Valuelist property-status
  • derivative action coefficient
  • controller output variable
  • set control mode
  • controlled variable
  • feedback variable
  • Valuelist actual control mode
  • Valuelist on/off
  • final controlled variable
  • dead time
  • Valuelist Address of company representative
  • URI of the product
  • Manufacturer order code
  • hardware version
  • software version
  • National stock number
  • fabrication number
  • integral action coefficient
  • proportional action coefficient
  • manipulated variable
  • command variable
  • reference variable
  • operating mode
  • control difference variable
  • Customs tariff number
  • Valuelist Type of customs tariff number
  • HS-Code of the WCO
  • Valuelist Use of customs tariff number
  • GLN of supplier
  • Manufacturer product root
  • Manufacturer product order suffix
  • Manufacturer product designation
  • Manufacturer product family
  • Brand
  • Manufacturer product description
  • Manufacturer name
  • GTIN
  • product article number of manufacturer
  • Supplier product root
  • Supplier product family
  • Supplier product type
  • Supplier product order suffix
  • name of supplier
  • product article number of supplier
  • Supplier product description
  • Supplier product designation
  • GLN of manufacturer
  • Product type
  • URI of manufacturer
  • failure rate
  • Valuelist state of the item
  • down time
  • repair time
  • up time
  • idle time
  • standby time
  • Valuelist maintenance level
  • mean downtime
  • operating time
  • time to restoration
  • Max tolerable water vapour inlet pressure
  • Max working pressure
  • Critical pre-vacuum pressure
  • production based availability
  • operational reliability
  • intrinsic maintainability
  • maintainability
  • time based availability
  • Reliability according to norm
  • Valuelist obsolescence
  • mean time to restauration
  • mean repair time
  • maintenance time
  • operating time between failures
  • external disabled time
  • active maintenance time
  • operating time to failure
  • norminal frequence
  • Nominal speed
  • Power factor (cos phi)
  • Torque at nominal speed, drive
  • nominal power consumption
  • height of the outlet connection
  • Valuelist discrete output value
  • Counterpressure
  • Coolant temperature
  • height of the inlet connection
  • Nominal size of nozzle/pipe
  • water vapour capacity
  • Nominal pressure
  • compression ratio
  • throughput
  • motor efficiency
  • Min. nominal frequency
  • Valuelist nominal pressure (PN) of the flange
  • nominal voltage
  • Max. nominal frequency
  • enclosure type no/class
  • Valuelist energy efficiency class (motor)
  • Valuelist guideline for conformity declaration
  • min. ambient temperature during operation
  • Valuelist Controllable
  • Quick-acting speed
  • Valuelist supported protocol
  • max. ambient temperature
  • max. temperature
  • sound pressure level
  • Rotational direction of the pump
  • min. air humidity
  • max. air humidity
  • Control types
  • Process pressure
  • pump humidity
  • Valuelist conformity declaration present
  • maximum axial load
  • sound power
  • maximum radial load
  • design axial load
  • sound energy level
  • declaration of conformity
  • design radial load
  • pump efficiency curve
  • pump curve
  • sound energy
  • possible fluid
  • min. temperature
  • Sound output level
  • Valuelist device type
  • pump power input curve
  • maximum ambient temperature (during operation)
  • minimum ambient temperature (during operation)
  • Useful life
  • min. temperature range
  • water vapour tolerable load
  • on off cycle
  • standard gas flowrate
  • maximum allowable throughput
  • cool-down time for a vapour jet pump or a diffusion pump
  • Starting pressure
  • warm-up time for a vapour jet pump or a diffusion pump
  • volume flow rate of backing pump
  • volume flow rate
  • Base pressure
  • Valuelist multi-phase
  • fluid
  • throughput
  • required control mode
  • gas content
  • Valuelist operating mode
  • height of the inlet side of the installation
  • height of the pump
  • Valuelist Field bus system
  • reference plane
  • height of the outlet side of the installation
  • working temperature
  • max. temperature range
  • solids volume fraction
  • mean time between failures (MTBF)
  • address of additional link
  • severity
  • number of failures
  • Valuelist process fluid fault - solid
  • corrective maintenance time
  • Valuelist process fluid fault - viscosity
  • Valuelist process fluid fault - temperature
  • Valuelist mechanical fault - axial bearing fault
  • Valuelist mechanical fault - axial bearing abrasion
  • Valuelist mechanical fault - unbalance
  • Valuelist pump operation fault - accessory liquid high
  • Valuelist pump operation fault - accessory liquid flow
  • Valuelist pump operation fault - accessory liquid low
  • Valuelist pump operation fault - accessory liquid overheat
  • Valuelist hardware fault - communication
  • Valuelist mechanical fault - rotor station rubbing
  • Valuelist pump operation fault - accessory liquid pressure
  • Valuelist process fluid fault - blockage
  • Valuelist software fault - software reset
  • Valuelist pump operation fault - motor humidity
  • Valuelist pump operation fault - maximum starts at time
  • Valuelist process fluid fault - dry
  • Valuelist mechanical fault - bearing fault
  • Valuelist process fluid fault - condensation
  • Valuelist process fluid fault - cavitation
  • Valuelist mechanical fault - brake overheat
  • Valuelist process fluid fault - flow
  • Valuelist mechanical fault - axial bearing overheat
  • Valuelist process fluid fault - gas
  • Valuelist process fluid fault - liquid
  • Valuelist process fluid fault - stall
  • Valuelist mechanical fault - brake chopper
  • Valuelist process fluid fault - pressure
  • Valuelist auxiliary device fault - mechanical damage
  • Valuelist hardware fault - DC link supply
  • Valuelist auxiliary device fault - operating conditions
  • Valuelist hardware fault - computing circuit
  • Valuelist hardware fault - IONA
  • Valuelist hardware fault - eprom
  • Valuelist auxiliary device fault - overloading
  • Valuelist hardware fault - control circuit
  • Valuelist auxiliary device fault - humidity electronics
  • Valuelist auxiliary device fault - line length
  • Valuelist auxiliary device fault - fouling
  • Valuelist auxiliary device fault - installation
  • Valuelist hardware fault - measure circuit
  • Valuelist hardware fault - ram
  • Valuelist auxiliary device fault - interruption
  • Valuelist hardware fault - network NA
  • Valuelist pump operation fault - converter overheat
  • Valuelist pump operation fault - controller overheat
  • Valuelist pump operation fault - case overheat
  • Valuelist pump operation fault - ambient temperature
  • Valuelist mechanical fault - gap wear
  • Valuelist mechanical fault - radial bearing fault
  • Valuelist mechanical fault - excess vibration
  • Valuelist mechanical fault - misalignment
  • Valuelist mechanical fault - radial bearing overheat
  • Valuelist electronic fault - voltage inside device
  • Valuelist mechanical fault - radial bearing abrasion
  • Valuelist mechanical fault - rotor blocked
  • Valuelist auxiliary device fault - measured material electronics
  • Valuelist auxiliary device fault - material electronics
  • Valuelist electronic fault - supply voltage low
  • Valuelist electronic fault - winding temperature
  • Valuelist pump operation fault - velocity limit
  • Valuelist pump operation fault - under speed
  • Valuelist auxiliary device fault - temperature shock
  • Valuelist auxiliary device fault - start up
  • Valuelist electronic fault - field circuit
  • Valuelist auxiliary device fault - auxiliary medium absence
  • Valuelist auxiliary device fault - actuator element
  • Valuelist pump operation fault - wear reserve exhausted
  • Valuelist electronic fault - insulation resistance
  • Valuelist electronic fault - installation fault
  • Valuelist electronic fault - current inside device
  • Valuelist auxiliary device fault - ambient temperature
  • Valuelist pump operation fault - turbine operation
  • Valuelist pump operation fault - torque limit
  • Valuelist auxiliary device fault - auxiliary medium insufficiency
  • Valuelist pump operation fault - TMS failure
  • Valuelist auxiliary device fault - wear reserve operation
  • Valuelist auxiliary device fault - vibration
  • Valuelist hardware fault - power supply
  • Valuelist hardware fault - uP
  • Valuelist auxiliary device fault - wear reserve wear
  • Valuelist software fault - application
  • Valuelist electronic fault - armature circuit
  • Valuelist software fault - communication
  • Valuelist software fault - parameter
  • Valuelist software fault - OS
  • Valuelist software fault - memory
  • Valuelist software fault - control
  • Valuelist auxiliary device fault - sensor element
  • Valuelist auxiliary device fault - process influence
  • Valuelist auxiliary device fault - peripheral
  • Valuelist auxiliary device fault - parameter setting
  • Valuelist auxiliary device fault - auxiliary power pole
  • Valuelist auxiliary device fault - corrosion
  • Valuelist electronic fault - supply voltage
  • Valuelist auxiliary device fault - auxiliary power range
  • Valuelist failure
  • Valuelist auxiliary device fault - communication error
  • criticality
  • durability
  • availability
  • inlet temperature of the pump
  • expected reliability
  • intrinsic reliability
  • instantaneous availability
  • Valuelist electronic fault - supply current
  • Valuelist electronic fault - short to earth
  • Valuelist electronic fault - short circuit
  • Valuelist electronic fault - phase failure
  • Valuelist auxiliary device fault - electromagnetic interference
  • Valuelist auxiliary device fault - deviation
  • Valuelist electronic fault - supply current low
  • Valuelist electronic fault - supply current high
  • Valuelist auxiliary device fault - electronic fault
  • Valuelist electronic fault - supply frequency low
  • Valuelist electronic fault - supply frequency
  • Valuelist auxiliary device fault - energy supply
  • Valuelist auxiliary device fault - evaluation electronics
  • Valuelist electronic fault - supply voltage high
  • Valuelist auxiliary device fault - exciter error
  • Valuelist electronic fault - supply frequency high
  • Pre-vacuum pressure
  • Valuelist discrete input value
  • voltage
  • Inlet pressure
  • power factor
  • DC link current
  • current
  • torque
  • frequency
  • energy consumption
  • driver power input
  • DC link voltage
  • pump kick time difference
  • pump kick time
  • Valuelist pump kick mode
  • clearance flow
  • pump temperature
  • electronic temperature
  • radial load of pump rotor
  • housing temperature
  • sound energy
  • hydraulic efficiency
  • sound energy level
  • power loss due to internal leakage
  • overall efficiency
  • outlet temperature of the pump
  • fluid temperature
  • Speed
  • motor voltage
  • motor temperature
  • motor current
  • level
  • mechanical efficiency
  • lubricating oil consumption
  • leakage rate of flow
  • axial load of pump rotor
  • number of starts
  • sound power
  • pump power output
  • axial rotor position
  • pump efficiency
  • bearing temperature
  • maximum dynamic sealing pressure
  • minimum allowable stable flow
  • pump mechanical power losses
  • hydraulic efficiency
  • atmospheric pressure
  • height of the outlet manometer
  • mechanical efficiency
  • height of the inlet manometer
  • Valuelist direction
  • Max. feed flow
  • Min. feed flow
  • category
  • ID carrier
  • last inspection date
  • next servicing date
  • next inspection date
  • active preventive maintenance time
  • installation date
  • last servicing date
  • preventive maintenance time
  • overall efficiency
  • inlet area of the pump
  • pump best efficiency
  • pump rated power input
  • useful life
  • pump efficiency
  • Valuelist pump operation fault - leakage
  • Valuelist pump operation fault - generator operation
  • Valuelist pump operation fault - drive overheat
  • Valuelist pump operation fault - dirty impeller
  • Valuelist pump operation fault - coolant low
  • Valuelist pump operation fault - maximum operation time
  • Valuelist pump operation fault - maximum number starts
  • Valuelist pump operation fault - lubricant
  • Valuelist pump operation fault - over speed
  • Valuelist pump operation fault - over load
  • Valuelist pump operation fault - operation fault
  • Valuelist pump operation fault - motor overheat
  • Valuelist pump operation fault - time out
  • Valuelist pump operation fault - temperature fault
  • Valuelist pump operation fault - synchronisation
  • Valuelist pump operation fault - partial load
  • distribution priority
  • Valuelist exchange mode
  • redundant pump Ids
  • Valuelist pump role
  • maximum number of pumps in operation
  • exchange time difference
  • Valuelist distribution type
  • exchange time
  • Number of Pumps
  • pump collective Ids
  • Valuelist operation mode
  • Valuelist pump operation fault - deceleration
  • Valuelist pump operation fault - coolant overheat
  • Valuelist pump operation fault - coolant high
  • Valuelist pump operation fault - coolant flow