Search the ECLASS content

ECLASS offers you the opportunity to have a look at and search the latest ECLASS Releases free of charge. The search function is intuitive and allows you to get to know the standard in a quick and non-bureaucratic manner.

How to use the ECLASS search

Please first select ...

  • whether you want to search ECLASS Basic or Advanced
  • in which Release version you want to search
  • in which language you want to search
  • whether you want to search in the classes or for properties, values etc.

Then enter a search term (e.g. "pencil") and click on "Search".
 

Please note that the application of the ECLASS Standard requires a license. (see also ECLASS Terms of Use)

eclass image

Classification: 51410104 [AGW109004]

Preferred name 51-41-01-04 Axial piston pump, swashplate design, variable (hydraulics)
Definition axial piston pump in which the drive shaft is in line with the common shaft, and the variable swashplate is not connected to the drive shaft
IRDI 0173-1#01-AGW109#004
Already on the watchlist: 0 of max. 4

BASIC Properties: Axial piston pump, swashplate design, variable (hydraulics)

  • specified minimum total flow rate
  • specified maximum total flow rate
  • maximum set control flow rate
  • set control flow rate
  • actual control flow rate
  • minimum set control flow rate
  • actual total flow rate
  • specified minimum mechanical power
  • actual maximum total flow rate
  • actual average total flow rate
  • nominal total flow rate
  • actual minimum total flow rate
  • frequency of measurement (fluid temperature)
  • specified minimum ambient temperature
  • maximum set ambient temperature
  • time of measurement (fluid temperature)
  • maximum set fluid temperature
  • minimum set ambient temperature
  • time of measurement (outlet pressure)
  • frequency of measurement (outlet pressure)
  • nominal starting torque
  • specified maximum starting torque
  • actual maximum ambient temperature
  • set ambient temperature
  • last ambient temperature
  • actual minimum ambient temperature
  • specified maximum ambient temperature
  • actual ambient temperature
  • frequency of measurement (inlet pressure)
  • start time of inlet pressure-measurement
  • set inlet pressure
  • time of measurement (inlet pressure)
  • minimum set inlet pressure
  • maximum set inlet pressure
  • actual inlet pressure
  • last inlet pressure
  • nominal outlet pressure
  • actual outlet pressure
  • specified minimum outlet pressure
  • specified maximum outlet pressure
  • specified maximum set pressure
  • set pressure
  • end time of inlet pressure-measurement
  • specified minimum set pressure
  • last flow ripple
  • minimum set working time (time)
  • actual flow ripple
  • minimum set working time (cycles)
  • actual average flow ripple
  • minimum set working time (mileage)
  • actual minimum flow ripple
  • actual maximum flow ripple
  • actual minimum inlet pressure
  • actual maximum inlet pressure
  • specified maximum inlet pressure
  • nominal inlet pressure
  • set flow ripple
  • specified minimum inlet pressure
  • minimum set flow ripple
  • maximum set flow ripple
  • set total flow rate
  • actual fluid temperature
  • Valuelist unit of measure
  • specified maximum fluid temperature
  • specified minimum fluid temperature
  • maximum set total flow rate
  • minimum set total flow rate
  • weight per unit of measure
  • specified minimum flow ripple
  • specified maximum flow ripple
  • minimum set fluid temperature
  • last total flow rate
  • actual maximum fluid temperature
  • set fluid temperature
  • last fluid temperature
  • actual minimum fluid temperature
  • remaining working time (time)
  • remaining operating time (time)
  • inlet pressure
  • inlet flow rate
  • burst pressure
  • through drive torque
  • assembly torque
  • working time (mileage)
  • Valuelist Max. admissible degree of contamination of hydraulic fluid (cleanliness class)
  • Valuelist Manual override
  • Valuelist Position sensing
  • control flow rate
  • hydraulic power
  • drive torque
  • set pressure
  • total flow rate
  • end value of the measuring range (pressure)
  • electrical power consumption
  • end value of the measuring range (temperature)
  • initial value of the measuring range (pressure)
  • differential pressure
  • outlet pressure
  • working time (time)
  • working time (cycles)
  • mechanical power
  • remaining working time (cycles)
  • flow ripple
  • storage temperature
  • product life (time)
  • end value of the measuring range (flow rate)
  • initial value of the measuring range (temperature)
  • operating time
  • fluid temperature
  • ambient temperature
  • flow rate
  • overload pressure
  • initial value of the measuring range (flow rate)
  • Manufacturer product designation
  • Brand
  • product article number of manufacturer
  • Manufacturer product family
  • GLN of manufacturer
  • Manufacturer product root
  • Manufacturer product order suffix
  • Product type
  • Supplier product type
  • name of supplier
  • Supplier product family
  • Supplier product description
  • GLN of supplier
  • Supplier product designation
  • URI of the product
  • GTIN
  • Manufacturer name
  • Manufacturer product description
  • Supplier product order suffix
  • Supplier product root
  • product article number of supplier
  • Valuelist Working port (standard)
  • Mounting pattern
  • Valuelist Direction of rotation
  • Valuelist Actuation type
  • Valuelist Type of shaft end
  • Valuelist Flow direction
  • MTTFd
  • Grade of filtration
  • Size
  • Valuelist material sealing
  • Construction series
  • Valuelist mounting orientation
  • Valuelist Pressure transmission medium
  • Valuelist Mounting pattern (standard)
  • hysteresis
  • Valuelist Type of customs tariff number
  • Customs tariff number
  • HS-Code of the WCO
  • Valuelist Use of customs tariff number
  • address of additional link
  • actual pressure difference
  • maximum set of remaining working time (mileage)
  • actual maximum pressure difference
  • specified minimum remaining working time (time)
  • actual minimum pressure difference
  • specified maximum remaining working time (time)
  • nominal pressure difference
  • maximum set of remaining working time (time)
  • design of the measuring connection
  • actual maximum electrical power consumption
  • actual electrical power consumption
  • last electrical power consumption
  • specified minimum pressure difference
  • specified maximum product life (time)
  • specified maximum remaining working time (mileage)
  • specified minimum remaining working time (mileage)
  • time of measurement (operating time)
  • specified minimum working time (time)
  • specified maximum operating time
  • specified minimum operating time
  • time of measurement (working time (cycles))
  • minimum set operating time
  • specified maximum working time (cycles)
  • specified minimum working time (cycles)
  • specified maximum pressure difference
  • specified minimum remaining working time (cycles)
  • maximum set of remaining working time (cycles)
  • specified maximum remaining working time (cycles)
  • last operating time
  • maximum set operating time
  • time of measurement (working time (time))
  • actual operating time
  • actual working time (time)
  • last working time (time)
  • actual working time (mileage)
  • last working time (mileage)
  • actual maximum assembly torque
  • actual minimum assembly torque
  • actual assembly torque
  • last assembly torque
  • actual average assembly torque
  • maximum set working time (cycles)
  • specified minimum assembly torque
  • last working time (cycles)
  • specified maximum assembly torque
  • actual working time (cycles)
  • maximum set working time (time)
  • specified maximum working time (time)
  • nominal assembly torque
  • set assembly torque
  • specified maximum drive torque
  • specified minimum drive torque
  • frequency of measurement (ambient temperature)
  • nominal drive torque
  • specified minimum starting torque
  • time of measurement (ambient temperature)
  • specified maximum through drive torque
  • specified minimum through drive torque
  • specified minimum working time (mileage)
  • nominal through drive torque
  • specified maximum working time (mileage)
  • minimum set assembly torque
  • maximum set working time (mileage)
  • maximum set assembly torque
  • specified minimum control flow rate
  • specified maximum mechanical power
  • frequency of measurement (inlet flow rate)
  • minimum set mechanical power
  • time of measurement (inlet flow rate)
  • maximum set mechanical power
  • set inlet flow rate
  • set mechanical power
  • min. storage temperature
  • min. dynamic viscosity
  • actual average inlet flow rate
  • actual inlet flow rate
  • actual maximum inlet flow rate
  • specified minimum hydraulic power
  • specified maximum control flow rate
  • specified maximum hydraulic power
  • last flow rate
  • minimum set flow rate
  • actual flow rate
  • specified minimum electrical power consumption
  • actual average flow rate
  • specified maximum electrical power consumption
  • actual minimum inlet flow rate
  • maximum set electrical power consumption
  • maximum set inlet flow rate
  • nominal mechanical power
  • minimum set inlet flow rate
  • actual minimum mechanical power
  • last inlet flow rate
  • actual maximum mechanical power
  • actual mechanical power
  • last mechanical power
  • set flow rate
  • actual minimum hydraulic power
  • maximum set flow rate
  • actual maximum hydraulic power
  • actual hydraulic power
  • last hydraulic power
  • load collective
  • signal feedback
  • specified maximum inlet flow rate
  • minimum set hydraulic power
  • specified minimum inlet flow rate
  • maximum set hydraulic power
  • frequency of measurement (flow rate)
  • set hydraulic power
  • time of measurement (flow rate)
  • nominal hydraulic power
  • actual maximum flow rate
  • maximum set of remaining operating time (time)
  • actual minimum flow rate
  • set electrical power consumption
  • nominal flow rate
  • nominal electrical power consumption
  • specified maximum flow rate
  • actual minimum electrical power consumption
  • set pressure difference
  • specified minimum flow rate
  • maximum set pressure difference
  • actual product life (time)
  • minimum set pressure difference
  • specified minimum remaining operating time (time)
  • last pressure difference
  • specified maximum remaining operating time (time)
  • Valuelist Pressure medium
  • max. storage temperature
  • max. dynamic viscosity
  • certification
X

We need your consent

This website uses necessary cookies to ensure the operation of the website. There is no analysis of user behavior by third parties. You can find detailed information about the use of cookies in our privacy policy.