Search the ECLASS content

ECLASS offers you the opportunity to have a look at and search the latest ECLASS Releases free of charge. The search function is intuitive and allows you to get to know the standard in a quick and non-bureaucratic manner.

How to use the ECLASS search

Please first select ...

  • whether you want to search ECLASS Basic or Advanced
  • in which Release version you want to search
  • in which language you want to search
  • whether you want to search in the classes or for properties, values etc.

Then enter a search term (e.g. "pencil") and click on "Search".
 

Please note that the application of the ECLASS Standard requires a license. (see also ECLASS Terms of Use)

eclass image

Classification: 51440204 [AGW216004]

Preferred name 51-44-02-04 Switching pressure cut-off valve (hydraulics)
Definition valve, which shifts in depressurized circulation or isolates the hydraulic consumer when the set pressure level is reached
IRDI 0173-1#01-AGW216#004
Already on the watchlist: 0 of max. 4

BASIC Properties: Switching pressure cut-off valve (hydraulics)

  • Manufacturer product family
  • product article number of manufacturer
  • GTIN
  • URI of the product
  • Manufacturer product description
  • Manufacturer name
  • Manufacturer product order suffix
  • Manufacturer product root
  • Product type
  • Brand
  • Manufacturer product designation
  • GLN of manufacturer
  • Supplier product description
  • Supplier product designation
  • GLN of supplier
  • product article number of supplier
  • Supplier product root
  • URI of manufacturer
  • Supplier product order suffix
  • name of supplier
  • Supplier product type
  • Supplier product family
  • closing pressure
  • control flow rate
  • remaining operating time (time)
  • switching pressure difference
  • remaining working time (time)
  • Min. range of pressure adjustment
  • Grade of filtration
  • MTTFd
  • Graphic symbol
  • Valuelist Manual override
  • Valuelist Max. admissible degree of contamination of hydraulic fluid (cleanliness class)
  • Valuelist Position sensing
  • Valuelist Pressure transmission medium
  • Valuelist mounting orientation
  • Valuelist Pressure limiting function available
  • Number of switchng positions
  • Valuelist Mounting pattern (standard)
  • Mounting pattern
  • Valuelist Actuation type
  • Max. range of pressure adjustment
  • Customs tariff number
  • Valuelist Type of customs tariff number
  • Valuelist Use of customs tariff number
  • HS-Code of the WCO
  • address of additional link
  • Valuelist material sealing
  • ambient temperature
  • overload pressure
  • product life (time)
  • hydraulic power
  • total flow rate
  • storage time
  • set pressure
  • electrical power consumption
  • fluid temperature
  • operating time
  • flow rate
  • working time (time)
  • remaining working time (cycles)
  • remaining working time (mileage)
  • cracking pressure
  • storage temperature
  • flow rate amplification
  • flow rate a-b
  • flow ripple
  • inlet flow rate
  • inlet pressure
  • burst pressure
  • working time (mileage)
  • assembly torque
  • outlet pressure
  • differential pressure
  • working time (cycles)
  • specified maximum assembly torque
  • actual working time (cycles)
  • minimum set assembly torque
  • specified minimum working time (mileage)
  • maximum set assembly torque
  • specified maximum working time (mileage)
  • set assembly torque
  • maximum set working time (mileage)
  • last assembly torque
  • maximum set flow rate from a to b
  • actual assembly torque
  • minimum set flow rate from a to b
  • actual average assembly torque
  • maximum set working time (cycles)
  • specified minimum assembly torque
  • last working time (cycles)
  • actual maximum flow rate from a to b
  • actual average flow from a to b
  • last working time (mileage)
  • actual minimum flow rate from a to b
  • actual minimum assembly torque
  • actual working time (mileage)
  • actual maximum assembly torque
  • set flow rate from a to b
  • last ambient temperature
  • actual minimum ambient temperature
  • specified maximum ambient temperature
  • actual ambient temperature
  • minimum set ambient temperature
  • maximum set ambient temperature
  • actual flow rate from a to b
  • last flow rate from a to b
  • nominal flow rate from a to b
  • last inlet pressure
  • specified maximum flow rate from a to b
  • actual inlet pressure
  • specified minimum flow rate from a to b
  • actual maximum inlet pressure
  • end time of inlet pressure-measurement
  • specified minimum set pressure
  • specified minimum inlet pressure
  • specified minimum flow rate amplification
  • maximum set flow ripple
  • set flow ripple
  • minimum set working time (time)
  • minimum set flow ripple
  • minimum set inlet pressure
  • last flow ripple
  • actual maximum flow ripple
  • actual average flow ripple
  • actual minimum inlet pressure
  • actual minimum flow ripple
  • nominal inlet pressure
  • nominal flow rate amplification
  • specified maximum inlet pressure
  • specified maximum flow rate amplification
  • specified minimum working time (cycles)
  • nominal assembly torque
  • specified maximum flow ripple
  • specified maximum working time (cycles)
  • minimum set working time (cycles)
  • specified minimum flow ripple
  • minimum set working time (mileage)
  • actual flow ripple
  • specified maximum outlet pressure
  • nominal outlet pressure
  • end value of the measuring range (pressure)
  • specified minimum outlet pressure
  • frequency of measurement (inlet pressure)
  • start time of inlet pressure-measurement
  • set inlet pressure
  • time of measurement (inlet pressure)
  • initial value of the measuring range (pressure)
  • maximum set inlet pressure
  • specified maximum set pressure
  • set pressure
  • maximum set inlet flow rate
  • actual minimum hydraulic power
  • last inlet flow rate
  • minimum set inlet flow rate
  • actual control flow rate
  • minimum set control flow rate
  • specified minimum control flow rate
  • specified maximum control flow rate
  • actual minimum inlet flow rate
  • specified maximum hydraulic power
  • specified maximum inlet flow rate
  • minimum set hydraulic power
  • specified minimum inlet flow rate
  • maximum set hydraulic power
  • nominal hydraulic power
  • set hydraulic power
  • actual hydraulic power
  • last hydraulic power
  • load collective
  • signal feedback
  • actual average inlet flow rate
  • actual inlet flow rate
  • actual maximum inlet flow rate
  • specified minimum hydraulic power
  • certification
  • max. electricity consumption
  • Cable length
  • max. storage temperature
  • set flow rate
  • Valuelist Design of control output
  • maximum set flow rate
  • actual maximum hydraulic power
  • Valuelist Labs-conformity to VDMA 24364
  • actual maximum fluid temperature
  • Valuelist type of switching input
  • actual minimum fluid temperature
  • specified maximum working time (time)
  • specified minimum working time (time)
  • last working time (time)
  • maximum set working time (time)
  • Valuelist unit of measure
  • specified maximum fluid temperature
  • specified minimum fluid temperature
  • maximum set total flow rate
  • minimum set total flow rate
  • weight per unit of measure
  • set fluid temperature
  • minimum set fluid temperature
  • actual minimum total flow rate
  • actual maximum total flow rate
  • last fluid temperature
  • nominal total flow rate
  • actual fluid temperature
  • max. electrical power consumption
  • set total flow rate
  • relative duty cycle
  • specified maximum total flow rate
  • set inlet flow rate
  • set control flow rate
  • specified minimum total flow rate
  • last total flow rate
  • maximum set control flow rate
  • actual average total flow rate
  • actual total flow rate
  • specified maximum remaining operating time (time)
  • minimum set pressure difference
  • maximum set of remaining operating time (time)
  • last pressure difference
  • specified minimum remaining working time (time)
  • actual pressure difference
  • specified maximum remaining working time (time)
  • actual maximum pressure difference
  • minimum set operating time
  • specified maximum operating time
  • specified minimum remaining working time (mileage)
  • specified minimum pressure difference
  • maximum set of remaining working time (cycles)
  • specified maximum remaining working time (mileage)
  • specified minimum remaining operating time (time)
  • maximum set pressure difference
  • nominal closing pressure
  • maximum set of remaining working time (mileage)
  • specified maximum closing pressure
  • specified maximum storage time
  • specified minimum closing pressure
  • actual storage time
  • actual cracking pressure
  • specified minimum operating time
  • nominal cracking pressure
  • actual working time (time)
  • maximum set operating time
  • specified maximum cracking pressure
  • last operating time
  • specified minimum cracking pressure
  • actual closing pressure
  • actual operating time
  • actual maximum electrical power consumption
  • specified maximum flow rate
  • minimum set flow rate
  • last electrical power consumption
  • maximum set fluid temperature
  • specified minimum ambient temperature
  • actual maximum ambient temperature
  • set ambient temperature
  • maximum set electrical power consumption
  • actual average flow rate
  • set electrical power consumption
  • actual maximum flow rate
  • nominal electrical power consumption
  • actual minimum flow rate
  • actual minimum electrical power consumption
  • nominal flow rate
  • actual electrical power consumption
  • actual product life (time)
  • last flow rate
  • specified maximum product life (time)
  • actual flow rate
  • specified minimum electrical power consumption
  • Valuelist control signal
  • specified maximum electrical power consumption
  • maximum set of remaining working time (time)
  • actual minimum pressure difference
  • specified minimum remaining working time (cycles)
  • nominal pressure difference
  • specified maximum remaining working time (cycles)
  • specified maximum pressure difference
  • set pressure difference
  • specified minimum flow rate
  • min. storage temperature
  • min. operating voltage with AC 50 Hz
  • min. operating voltage with DC
  • Valuelist Pressure medium
  • Dimensions
  • min. operating voltage with AC 60 Hz
  • max. operating voltage with AC 50 Hz
  • Valuelist style of communication interface
  • Valuelist Integrated protective circuitry present
  • Number of poles
  • max. operating voltage with DC
  • Max. output current
  • Rated operating voltage Ue with AC
  • Valuelist Conductor connection method
  • max. operating voltage with AC 60 Hz
  • Open circuit current
  • nominal electricity consumption
  • Max. switching power
X

We need your consent

This website uses necessary cookies to ensure the operation of the website. There is no analysis of user behavior by third parties. You can find detailed information about the use of cookies in our privacy policy.