Classification: 51450101 [AKE916015]

Preferred name 51-45-01-01 Proportional directional control valve, poppet design (hydraulics)
Definition valve that connects or isolates one or more flow paths, and in which the output is proportional to the value of the control input
IRDI 0173-1#01-AKE916#015
Already on the watchlist: 0 of max. 4

BASIC Properties: Proportional directional control valve, poppet design (hydraulics)

  • Manufacturer product designation
  • URI of the product
  • GLN of manufacturer
  • Product type
  • Manufacturer name
  • GTIN
  • Brand
  • Manufacturer product description
  • Manufacturer product order suffix
  • product article number of manufacturer
  • URI of manufacturer
  • Manufacturer product root
  • Manufacturer product family
  • product life (time)
  • overload pressure
  • ambient temperature
  • flow rate
  • operating time
  • product article number of supplier
  • fluid temperature
  • electrical power consumption
  • storage time
  • name of supplier
  • total flow rate
  • Supplier product order suffix
  • hydraulic power
  • Supplier product family
  • flow ripple
  • Supplier product type
  • flow rate a-b
  • Supplier product description
  • GLN of supplier
  • Supplier product root
  • Supplier product designation
  • Valuelist Use of customs tariff number
  • Valuelist Type of customs tariff number
  • Customs tariff number
  • HS-Code of the WCO
  • customs tariff number (TARIC)
  • address of additional link
  • closing pressure
  • control flow rate
  • inlet pressure
  • inlet flow rate
  • remaining working time (time)
  • remaining operating time (time)
  • outlet pressure
  • assembly torque
  • working time (mileage)
  • burst pressure
  • remaining working time (cycles)
  • working time (time)
  • working time (cycles)
  • differential pressure
  • flow rate amplification
  • storage temperature
  • cracking pressure
  • remaining working time (mileage)
  • nominal assembly torque
  • specified minimum working time (cycles)
  • maximum set working time (mileage)
  • set assembly torque
  • specified maximum flow ripple
  • specified minimum flow ripple
  • specified maximum working time (cycles)
  • maximum adjustable range of ramp time
  • minimum set working time (mileage)
  • actual average flow ripple
  • minimum set working time (cycles)
  • actual flow ripple
  • actual minimum inlet pressure
  • nominal flow rate amplification
  • actual maximum flow ripple
  • actual minimum flow ripple
  • specified maximum inlet pressure
  • specified minimum flow rate amplification
  • nominal inlet pressure
  • specified maximum flow rate amplification
  • maximum set flow ripple
  • minimum set flow ripple
  • specified minimum inlet pressure
  • set flow ripple
  • minimum set inlet pressure
  • last inlet pressure
  • minimum set working time (time)
  • last flow ripple
  • specified maximum flow rate from a to b
  • actual maximum inlet pressure
  • nominal flow rate from a to b
  • actual inlet pressure
  • frequency of measurement (inlet pressure)
  • time of measurement (inlet pressure)
  • specified minimum flow rate from a to b
  • start time of inlet pressure-measurement
  • set inlet pressure
  • maximum set inlet pressure
  • actual minimum pressure difference
  • maximum set of remaining working time (time)
  • actual maximum pressure difference
  • specified maximum remaining working time (time)
  • specified maximum pressure difference
  • specified maximum remaining working time (cycles)
  • nominal pressure difference
  • specified minimum remaining working time (cycles)
  • actual product life (time)
  • actual electrical power consumption
  • specified minimum flow rate
  • set pressure difference
  • specified minimum electrical power consumption
  • actual flow rate
  • specified maximum product life (time)
  • last flow rate
  • actual average flow rate
  • maximum set electrical power consumption
  • specified maximum electrical power consumption
  • Valuelist control signal
  • actual minimum flow rate
  • nominal electrical power consumption
  • actual maximum flow rate
  • set electrical power consumption
  • specified maximum flow rate
  • actual maximum electrical power consumption
  • nominal flow rate
  • actual minimum electrical power consumption
  • specified minimum ambient temperature
  • maximum set fluid temperature
  • last electrical power consumption
  • minimum set flow rate
  • actual minimum ambient temperature
  • last ambient temperature
  • set ambient temperature
  • actual maximum ambient temperature
  • maximum set ambient temperature
  • minimum set ambient temperature
  • actual ambient temperature
  • specified maximum ambient temperature
  • actual average flow from a to b
  • actual maximum flow rate from a to b
  • last flow rate from a to b
  • actual flow rate from a to b
  • actual working time (mileage)
  • actual minimum assembly torque
  • actual minimum flow rate from a to b
  • last working time (mileage)
  • maximum set flow rate from a to b
  • last assembly torque
  • set flow rate from a to b
  • actual maximum assembly torque
  • maximum set working time (cycles)
  • actual average assembly torque
  • minimum set flow rate from a to b
  • actual assembly torque
  • actual working time (cycles)
  • specified maximum assembly torque
  • last working time (cycles)
  • specified minimum assembly torque
  • specified maximum working time (mileage)
  • maximum set assembly torque
  • specified minimum working time (mileage)
  • minimum set assembly torque
  • specified minimum total flow rate
  • set control flow rate
  • set inlet flow rate
  • specified maximum total flow rate
  • actual total flow rate
  • actual average total flow rate
  • maximum set control flow rate
  • last total flow rate
  • nominal total flow rate
  • last fluid temperature
  • actual maximum total flow rate
  • actual minimum total flow rate
  • relative duty cycle
  • set total flow rate
  • max. electrical power consumption
  • actual fluid temperature
  • maximum set total flow rate
  • specified minimum fluid temperature
  • specified maximum fluid temperature
  • Valuelist unit of measure
  • minimum set fluid temperature
  • set fluid temperature
  • weight per unit of measure
  • minimum set total flow rate
  • actual minimum fluid temperature
  • Valuelist type of switching input
  • actual maximum fluid temperature
  • Valuelist Labs-conformity to VDMA 24364
  • maximum set working time (time)
  • last working time (time)
  • specified minimum working time (time)
  • specified maximum working time (time)
  • Valuelist maximum admissible degree of contamination of pilot fluid (cleanliness class)
  • nominal cracking pressure
  • number of flow paths
  • actual working time (time)
  • specified minimum cracking pressure
  • last operating time
  • specified maximum cracking pressure
  • maximum set operating time
  • maximum set of remaining working time (mileage)
  • nominal closing pressure
  • actual operating time
  • actual closing pressure
  • actual storage time
  • specified minimum closing pressure
  • specified maximum storage time
  • specified maximum closing pressure
  • specified maximum operating time
  • minimum set operating time
  • specified minimum operating time
  • actual cracking pressure
  • specified maximum remaining working time (mileage)
  • maximum set of remaining working time (cycles)
  • specified minimum pressure difference
  • specified minimum remaining working time (mileage)
  • minimum set pressure difference
  • specified maximum remaining operating time (time)
  • maximum set pressure difference
  • specified minimum remaining operating time (time)
  • actual pressure difference
  • specified minimum remaining working time (time)
  • last pressure difference
  • maximum set of remaining operating time (time)
  • nominal electricity consumption
  • Number of poles
  • Max. switching power
  • nominal current
  • max. operating voltage with DC
  • Valuelist Conductor connection method
  • Valuelist Integrated protective circuitry present
  • Max. output current
  • Open circuit current
  • max. operating voltage with AC 60 Hz
  • MTTFd
  • Rated operating voltage Ue with AC
  • Valuelist Pressure medium
  • min. operating voltage with DC
  • min. operating voltage with AC 50 Hz
  • min. storage temperature
  • Valuelist style of communication interface
  • max. operating voltage with AC 50 Hz
  • min. operating voltage with AC 60 Hz
  • Dimensions
  • max. storage temperature
  • Cable length
  • max. electricity consumption
  • certification
  • actual maximum hydraulic power
  • maximum set flow rate
  • Valuelist Design of control output
  • set flow rate
  • signal feedback
  • load collective
  • last hydraulic power
  • actual hydraulic power
  • specified minimum hydraulic power
  • actual maximum inlet flow rate
  • actual inlet flow rate
  • actual average inlet flow rate
  • minimum set hydraulic power
  • specified maximum inlet flow rate
  • specified maximum hydraulic power
  • actual minimum inlet flow rate
  • set hydraulic power
  • nominal hydraulic power
  • maximum set hydraulic power
  • specified minimum inlet flow rate
  • minimum set inlet flow rate
  • last inlet flow rate
  • actual minimum hydraulic power
  • maximum set inlet flow rate
  • specified maximum control flow rate
  • specified minimum control flow rate
  • minimum set control flow rate
  • actual control flow rate
  • product identifier