Classification: 51460101 [AGW239005]

Preferred name 51-46-01-01 Two-port slip-in cartridge valve, directional function (hydraulics)
Definition valve, designed as Two-port slip-in cartridge valve, that connects or isolates a flow path
IRDI 0173-1#01-AGW239#005
Already on the watchlist: 0 of max. 4

BASIC Properties: Two-port slip-in cartridge valve, directional function (hydraulics)

  • specified minimum flow ripple
  • specified maximum flow ripple
  • actual flow ripple
  • minimum set working time (cycles)
  • actual average flow ripple
  • minimum set working time (mileage)
  • actual minimum flow ripple
  • actual maximum flow ripple
  • maximum set assembly torque
  • Supplier product description
  • specified maximum working time (mileage)
  • GLN of supplier
  • set assembly torque
  • Supplier product designation
  • maximum set working time (mileage)
  • Supplier product root
  • poppet area ratio
  • product article number of supplier
  • nominal assembly torque
  • specified maximum working time (cycles)
  • specified minimum working time (cycles)
  • actual average assembly torque
  • URI of manufacturer
  • maximum set working time (cycles)
  • Supplier product order suffix
  • specified minimum assembly torque
  • last working time (cycles)
  • Supplier product type
  • specified maximum assembly torque
  • name of supplier
  • actual working time (cycles)
  • Supplier product family
  • minimum set assembly torque
  • specified minimum working time (mileage)
  • product article number of manufacturer
  • actual minimum assembly torque
  • Manufacturer product family
  • actual working time (mileage)
  • actual maximum assembly torque
  • set flow rate from a to b
  • URI of the product
  • last assembly torque
  • GTIN
  • maximum set flow rate from a to b
  • Manufacturer name
  • actual assembly torque
  • Manufacturer product description
  • minimum set flow rate from a to b
  • Manufacturer product root
  • minimum set ambient temperature
  • Manufacturer product order suffix
  • maximum set ambient temperature
  • Product type
  • actual flow rate from a to b
  • last flow rate from a to b
  • Manufacturer product designation
  • actual maximum flow rate from a to b
  • Brand
  • actual average flow from a to b
  • last working time (mileage)
  • actual minimum flow rate from a to b
  • maximum set fluid temperature
  • specified minimum ambient temperature
  • actual maximum ambient temperature
  • set ambient temperature
  • last ambient temperature
  • actual minimum ambient temperature
  • GLN of manufacturer
  • specified maximum ambient temperature
  • actual ambient temperature
  • nominal electrical power consumption
  • actual minimum flow rate
  • actual minimum electrical power consumption
  • nominal flow rate
  • actual maximum electrical power consumption
  • specified maximum flow rate
  • minimum set flow rate
  • last electrical power consumption
  • actual flow rate
  • specified minimum electrical power consumption
  • Valuelist control signal
  • specified maximum electrical power consumption
  • maximum set electrical power consumption
  • actual average flow rate
  • set electrical power consumption
  • actual maximum flow rate
  • specified maximum remaining working time (cycles)
  • specified maximum pressure difference
  • set pressure difference
  • specified minimum flow rate
  • actual electrical power consumption
  • actual product life (time)
  • last flow rate
  • specified maximum product life (time)
  • specified minimum remaining working time (time)
  • actual pressure difference
  • specified maximum remaining working time (time)
  • actual maximum pressure difference
  • maximum set of remaining working time (time)
  • actual minimum pressure difference
  • specified minimum remaining working time (cycles)
  • nominal pressure difference
  • maximum set of remaining working time (cycles)
  • specified maximum remaining working time (mileage)
  • specified minimum remaining operating time (time)
  • maximum set pressure difference
  • specified maximum remaining operating time (time)
  • minimum set pressure difference
  • maximum set of remaining operating time (time)
  • last pressure difference
  • specified minimum closing pressure
  • actual storage time
  • actual cracking pressure
  • specified minimum operating time
  • minimum set operating time
  • specified maximum operating time
  • specified minimum remaining working time (mileage)
  • specified minimum pressure difference
  • last operating time
  • specified minimum cracking pressure
  • actual closing pressure
  • actual operating time
  • nominal closing pressure
  • maximum set of remaining working time (mileage)
  • specified maximum closing pressure
  • specified maximum storage time
  • maximum set working time (time)
  • specified maximum working time (time)
  • actual working time (time)
  • last working time (time)
  • nominal cracking pressure
  • overlap degree
  • maximum set operating time
  • specified maximum cracking pressure
  • minimum set fluid temperature
  • minimum set total flow rate
  • actual maximum fluid temperature
  • set fluid temperature
  • actual minimum fluid temperature
  • Valuelist Labs-conformity to VDMA 24364
  • specified minimum working time (time)
  • Valuelist type of switching input
  • relative duty cycle
  • actual fluid temperature
  • specified maximum fluid temperature
  • set total flow rate
  • maximum set total flow rate
  • Valuelist unit of measure
  • weight per unit of measure
  • specified minimum fluid temperature
  • storage temperature
  • cracking pressure
  • working time (mileage)
  • working time (cycles)
  • burst pressure
  • storage time
  • outlet pressure
  • hydraulic power
  • flow ripple
  • flow rate amplification
  • differential pressure
  • flow rate a-b
  • remaining working time (cycles)
  • working time (time)
  • assembly torque
  • remaining working time (mileage)
  • remaining operating time (time)
  • remaining working time (time)
  • flow rate
  • product life (time)
  • control flow rate
  • ambient temperature
  • closing pressure
  • overload pressure
  • operating time
  • total flow rate
  • electrical power consumption
  • fluid temperature
  • inlet flow rate
  • inlet pressure
  • Valuelist Actuation type
  • Mounting pattern
  • MTTFd
  • Grade of filtration
  • Valuelist Manual override
  • Graphic symbol
  • Valuelist Position sensing
  • Valuelist Max. admissible degree of contamination of hydraulic fluid (cleanliness class)
  • address of additional link
  • actual maximum inlet pressure
  • specified maximum flow rate from a to b
  • Valuelist Pressure transmission medium
  • start time of inlet pressure-measurement
  • Valuelist material sealing
  • specified minimum flow rate from a to b
  • Valuelist Pressure limiting function available
  • time of measurement (inlet pressure)
  • Valuelist mounting orientation
  • frequency of measurement (inlet pressure)
  • Valuelist Mounting pattern (standard)
  • maximum set inlet pressure
  • Number of switchng positions
  • set inlet pressure
  • minimum set flow ripple
  • maximum set flow ripple
  • Valuelist Type of customs tariff number
  • last flow ripple
  • Customs tariff number
  • minimum set working time (time)
  • HS-Code of the WCO
  • last inlet pressure
  • Valuelist Use of customs tariff number
  • minimum set inlet pressure
  • actual inlet pressure
  • nominal flow rate from a to b
  • nominal flow rate amplification
  • actual minimum inlet pressure
  • specified maximum flow rate amplification
  • nominal inlet pressure
  • specified minimum flow rate amplification
  • specified maximum inlet pressure
  • set flow ripple
  • specified minimum inlet pressure
  • actual average total flow rate
  • actual total flow rate
  • Valuelist lap
  • actual maximum total flow rate
  • nominal total flow rate
  • actual minimum total flow rate
  • max. electrical power consumption
  • last fluid temperature
  • specified minimum control flow rate
  • specified maximum control flow rate
  • specified maximum total flow rate
  • set inlet flow rate
  • set control flow rate
  • specified minimum total flow rate
  • last total flow rate
  • maximum set control flow rate
  • nominal hydraulic power
  • set hydraulic power
  • maximum set inlet flow rate
  • actual minimum hydraulic power
  • last inlet flow rate
  • minimum set inlet flow rate
  • actual control flow rate
  • minimum set control flow rate
  • actual maximum inlet flow rate
  • specified minimum hydraulic power
  • actual minimum inlet flow rate
  • specified maximum hydraulic power
  • specified maximum inlet flow rate
  • minimum set hydraulic power
  • specified minimum inlet flow rate
  • maximum set hydraulic power
  • maximum set flow rate
  • actual maximum hydraulic power
  • actual hydraulic power
  • last hydraulic power
  • load collective
  • signal feedback
  • actual average inlet flow rate
  • actual inlet flow rate
  • max. operating voltage with AC 50 Hz
  • Valuelist style of communication interface
  • certification
  • max. electricity consumption
  • Cable length
  • max. storage temperature
  • set flow rate
  • Valuelist Design of control output
  • max. operating voltage with AC 60 Hz
  • Open circuit current
  • min. storage temperature
  • min. operating voltage with AC 50 Hz
  • min. operating voltage with DC
  • Valuelist Pressure medium
  • Dimensions
  • min. operating voltage with AC 60 Hz
  • nominal electricity consumption
  • Max. switching power
  • Valuelist Integrated protective circuitry present
  • Number of poles
  • max. operating voltage with DC
  • Max. output current
  • Rated operating voltage Ue with AC
  • Valuelist Conductor connection method