Search the ECLASS content

ECLASS offers you the opportunity to have a look at and search the latest ECLASS Releases free of charge. The search function is intuitive and allows you to get to know the standard in a quick and non-bureaucratic manner.

How to use the ECLASS search

Please first select ...

  • whether you want to search ECLASS Basic or Advanced
  • in which Release version you want to search
  • in which language you want to search
  • whether you want to search in the classes or for properties, values etc.

Then enter a search term (e.g. "pencil") and click on "Search".
 

Please note that the application of the ECLASS Standard requires a license. (see also ECLASS Terms of Use)

eclass image

Classification: 51460201 [AGW243004]

Preferred name 51-46-02-01 Two-port slip-in cartridge valve, pressure cut-off function (hydraulics)
Definition valve, designed as two-port slip-in cartridge, which shifts in depressurized circulation or isolates the hydraulic consumer when the set pressure level is reached
IRDI 0173-1#01-AGW243#004
Already on the watchlist: 0 of max. 4

BASIC Properties: Two-port slip-in cartridge valve, pressure cut-off function (hydraulics)

  • GLN of manufacturer
  • Manufacturer product root
  • Manufacturer product order suffix
  • product article number of manufacturer
  • Manufacturer product family
  • Product type
  • Manufacturer product designation
  • Brand
  • Manufacturer name
  • Manufacturer product description
  • URI of the product
  • GTIN
  • Supplier product family
  • Supplier product description
  • Supplier product order suffix
  • Supplier product type
  • name of supplier
  • GLN of supplier
  • Supplier product designation
  • Supplier product root
  • product article number of supplier
  • Customs tariff number
  • Valuelist material sealing
  • address of additional link
  • Valuelist mounting orientation
  • Valuelist Pressure transmission medium
  • Valuelist Use of customs tariff number
  • Valuelist Type of customs tariff number
  • HS-Code of the WCO
  • Max. range of pressure adjustment
  • Valuelist Actuation type
  • Grade of filtration
  • Min. range of pressure adjustment
  • Number of switchng positions
  • Valuelist Pressure limiting function available
  • Mounting pattern
  • Valuelist Mounting pattern (standard)
  • Valuelist Position sensing
  • Graphic symbol
  • MTTFd
  • Valuelist Max. admissible degree of contamination of hydraulic fluid (cleanliness class)
  • Valuelist Manual override
  • inlet pressure
  • electrical power consumption
  • inlet flow rate
  • set pressure
  • total flow rate
  • fluid temperature
  • operating time
  • control flow rate
  • ambient temperature
  • closing pressure
  • overload pressure
  • remaining operating time (time)
  • remaining working time (time)
  • flow rate
  • product life (time)
  • remaining working time (cycles)
  • working time (time)
  • assembly torque
  • remaining working time (mileage)
  • flow ripple
  • flow rate amplification
  • differential pressure
  • flow rate a-b
  • burst pressure
  • storage time
  • outlet pressure
  • hydraulic power
  • storage temperature
  • cracking pressure
  • working time (mileage)
  • working time (cycles)
  • specified maximum pressure difference
  • nominal cracking pressure
  • maximum set of remaining working time (cycles)
  • specified maximum remaining working time (cycles)
  • specified maximum storage time
  • nominal closing pressure
  • actual storage time
  • specified maximum closing pressure
  • actual product life (time)
  • set pressure difference
  • specified minimum remaining operating time (time)
  • maximum set pressure difference
  • maximum set of remaining working time (time)
  • actual minimum pressure difference
  • specified minimum remaining working time (cycles)
  • nominal pressure difference
  • minimum set pressure difference
  • specified maximum remaining working time (time)
  • last pressure difference
  • specified maximum remaining operating time (time)
  • actual pressure difference
  • specified minimum flow rate
  • actual maximum pressure difference
  • specified minimum remaining working time (time)
  • maximum set of remaining operating time (time)
  • actual maximum inlet flow rate
  • specified minimum hydraulic power
  • set inlet flow rate
  • specified maximum hydraulic power
  • specified maximum inlet flow rate
  • minimum set hydraulic power
  • actual average inlet flow rate
  • maximum set hydraulic power
  • minimum set control flow rate
  • specified minimum control flow rate
  • nominal total flow rate
  • actual control flow rate
  • minimum set inlet flow rate
  • maximum set inlet flow rate
  • specified maximum control flow rate
  • last inlet flow rate
  • set control flow rate
  • specified minimum total flow rate
  • actual average total flow rate
  • actual total flow rate
  • actual maximum total flow rate
  • specified maximum total flow rate
  • maximum set control flow rate
  • actual minimum total flow rate
  • maximum set working time (cycles)
  • specified maximum working time (cycles)
  • poppet area ratio
  • actual average assembly torque
  • maximum set working time (mileage)
  • last total flow rate
  • nominal assembly torque
  • set assembly torque
  • last working time (cycles)
  • maximum set assembly torque
  • actual working time (cycles)
  • specified minimum assembly torque
  • specified minimum working time (mileage)
  • specified minimum working time (cycles)
  • specified maximum working time (mileage)
  • minimum set assembly torque
  • actual working time (time)
  • last working time (time)
  • specified maximum cracking pressure
  • actual operating time
  • last working time (mileage)
  • specified maximum assembly torque
  • actual minimum assembly torque
  • actual working time (mileage)
  • specified minimum working time (time)
  • maximum set working time (time)
  • specified minimum operating time
  • minimum set operating time
  • specified minimum cracking pressure
  • maximum set operating time
  • specified maximum working time (time)
  • last operating time
  • specified minimum pressure difference
  • maximum set of remaining working time (mileage)
  • specified minimum closing pressure
  • specified minimum remaining working time (mileage)
  • specified maximum operating time
  • actual cracking pressure
  • actual closing pressure
  • specified maximum remaining working time (mileage)
  • minimum set working time (cycles)
  • specified minimum flow ripple
  • minimum set working time (mileage)
  • actual flow ripple
  • specified maximum flow ripple
  • actual minimum flow ripple
  • actual maximum flow ripple
  • actual average flow ripple
  • nominal flow rate from a to b
  • last inlet pressure
  • specified maximum flow rate from a to b
  • actual inlet pressure
  • specified minimum flow rate from a to b
  • actual maximum inlet pressure
  • nominal flow rate amplification
  • actual minimum inlet pressure
  • specified maximum inlet pressure
  • specified maximum flow rate amplification
  • minimum set inlet pressure
  • specified minimum flow rate amplification
  • set flow ripple
  • specified minimum inlet pressure
  • nominal inlet pressure
  • maximum set flow ripple
  • start time of inlet pressure-measurement
  • time of measurement (inlet pressure)
  • maximum set inlet pressure
  • set inlet pressure
  • minimum set working time (time)
  • minimum set flow ripple
  • frequency of measurement (inlet pressure)
  • last flow ripple
  • actual maximum electrical power consumption
  • specified maximum flow rate
  • minimum set flow rate
  • specified maximum product life (time)
  • actual electrical power consumption
  • last electrical power consumption
  • actual minimum electrical power consumption
  • nominal flow rate
  • nominal electrical power consumption
  • actual minimum flow rate
  • specified maximum electrical power consumption
  • actual flow rate
  • specified minimum electrical power consumption
  • last flow rate
  • set electrical power consumption
  • actual maximum flow rate
  • actual maximum hydraulic power
  • set flow rate
  • set hydraulic power
  • specified minimum inlet flow rate
  • actual average flow rate
  • Valuelist control signal
  • actual minimum hydraulic power
  • maximum set electrical power consumption
  • signal feedback
  • actual hydraulic power
  • actual minimum inlet flow rate
  • actual inlet flow rate
  • load collective
  • nominal hydraulic power
  • last hydraulic power
  • maximum set flow rate
  • Max. switching power
  • Rated operating voltage Ue with AC
  • nominal electricity consumption
  • Max. output current
  • max. operating voltage with AC 50 Hz
  • min. operating voltage with AC 60 Hz
  • max. electricity consumption
  • Valuelist Conductor connection method
  • min. operating voltage with AC 50 Hz
  • min. storage temperature
  • Valuelist Integrated protective circuitry present
  • max. operating voltage with AC 60 Hz
  • min. operating voltage with DC
  • max. storage temperature
  • Cable length
  • Valuelist Design of control output
  • Valuelist Pressure medium
  • Dimensions
  • Open circuit current
  • max. operating voltage with DC
  • Number of poles
  • actual ambient temperature
  • last ambient temperature
  • maximum set ambient temperature
  • maximum set fluid temperature
  • Valuelist style of communication interface
  • certification
  • specified minimum ambient temperature
  • specified maximum ambient temperature
  • actual assembly torque
  • minimum set flow rate from a to b
  • set flow rate from a to b
  • last flow rate from a to b
  • actual maximum ambient temperature
  • minimum set ambient temperature
  • set ambient temperature
  • actual minimum ambient temperature
  • actual flow rate from a to b
  • actual minimum flow rate from a to b
  • actual minimum fluid temperature
  • actual average flow from a to b
  • maximum set flow rate from a to b
  • actual maximum assembly torque
  • actual maximum flow rate from a to b
  • last assembly torque
  • Valuelist Labs-conformity to VDMA 24364
  • actual maximum fluid temperature
  • specified minimum fluid temperature
  • maximum set total flow rate
  • last fluid temperature
  • Valuelist type of switching input
  • set fluid temperature
  • max. electrical power consumption
  • specified maximum fluid temperature
  • set total flow rate
  • minimum set fluid temperature
  • Valuelist unit of measure
  • minimum set total flow rate
  • weight per unit of measure
  • relative duty cycle
  • actual fluid temperature
X

We need your consent

This website uses necessary cookies to ensure the operation of the website. There is no analysis of user behavior by third parties. You can find detailed information about the use of cookies in our privacy policy.