Classification: 51490103 [AGW299004]

Preferred name 51-49-01-03 Power unit with control system, power class high (hydraulics)
Definition assembly of a prime mover, pump with or without a reservoir and accessories with control system, prime mover power class > 30 kW
IRDI 0173-1#01-AGW299#004
Already on the watchlist: 0 of max. 4

BASIC Properties: Power unit with control system, power class high (hydraulics)

  • maximum set ambient temperature
  • specified maximum control flow rate
  • time of measurement (fluid temperature)
  • frequency of measurement (fluid temperature)
  • specified minimum ambient temperature
  • specified maximum ambient temperature
  • actual ambient temperature
  • last ambient temperature
  • actual average flow rate
  • specified maximum electrical power consumption
  • actual flow rate
  • specified minimum electrical power consumption
  • last flow rate
  • minimum set flow rate
  • minimum set ambient temperature
  • specified minimum control flow rate
  • maximum set flow rate
  • actual maximum hydraulic power
  • set flow rate
  • actual minimum hydraulic power
  • time of measurement (flow rate)
  • frequency of measurement (flow rate)
  • maximum set fluid temperature
  • maximum set electrical power consumption
  • maximum set of remaining operating time (time)
  • specified maximum remaining operating time (time)
  • specified minimum remaining operating time (time)
  • specified minimum flow rate
  • load collective
  • signal feedback
  • actual hydraulic power
  • last hydraulic power
  • actual minimum ambient temperature
  • actual maximum ambient temperature
  • set ambient temperature
  • min. storage temperature
  • certification
  • max. storage temperature
  • specified maximum operating time
  • specified minimum operating time
  • time of measurement (operating time)
  • frequency of measurement (operating time)
  • specified minimum working time (time)
  • maximum set switching pressure difference
  • time of measurement (working time (time))
  • set switching pressure difference
  • last working time (time)
  • nominal switching pressure difference
  • maximum set working time (time)
  • actual switching pressure difference
  • specified maximum working time (time)
  • minimum set switching pressure difference
  • minimum set working time (time)
  • minimum set operating time
  • actual fluid temperature
  • last fluid temperature
  • actual minimum fluid temperature
  • actual maximum fluid temperature
  • set fluid temperature
  • minimum set fluid temperature
  • last total flow rate
  • actual working time (time)
  • actual control flow rate
  • frequency of measurement (ambient temperature)
  • minimum set control flow rate
  • minimum set total flow rate
  • specified minimum fluid temperature
  • maximum set total flow rate
  • specified maximum fluid temperature
  • set total flow rate
  • specified maximum flow rate
  • specified maximum switching pressure difference
  • actual minimum electrical power consumption
  • nominal flow rate
  • nominal electrical power consumption
  • actual minimum flow rate
  • set electrical power consumption
  • actual maximum flow rate
  • time of measurement (outlet pressure)
  • frequency of measurement (outlet pressure)
  • actual electrical power consumption
  • switching pressure difference
  • last electrical power consumption
  • end value of the measuring range (flow rate)
  • specified minimum switching pressure difference
  • actual maximum electrical power consumption
  • specified minimum remaining working time (time)
  • actual storage time
  • specified maximum storage time
  • end value of the measuring range (pressure)
  • specified minimum outlet pressure
  • specified maximum outlet pressure
  • nominal outlet pressure
  • actual outlet pressure
  • frequency of measurement (working time (time))
  • time of measurement (switching pressure difference)
  • actual operating time
  • frequency of measurement (switching pressure difference)
  • last operating time
  • maximum set operating time
  • maximum set of remaining working time (time)
  • specified maximum remaining working time (time)
  • actual minimum total flow rate
  • minimum set pneumatic power
  • actual maximum total flow rate
  • specified maximum pneumatic power
  • actual average total flow rate
  • specified minimum pneumatic power
  • actual total flow rate
  • time of measurement (ambient temperature)
  • set control flow rate
  • actual minimum pneumatic power
  • specified minimum total flow rate
  • nominal pneumatic power
  • specified maximum total flow rate
  • set pneumatic power
  • nominal total flow rate
  • maximum set pneumatic power
  • actual pneumatic power
  • last pneumatic power
  • maximum set control flow rate
  • actual maximum pneumatic power
  • address of additional link
  • HS-Code of the WCO
  • Valuelist Use of customs tariff number
  • Valuelist Type of customs tariff number
  • Customs tariff number
  • Brand
  • Product type
  • Manufacturer product root
  • Manufacturer product order suffix
  • GLN of manufacturer
  • GTIN
  • product article number of manufacturer
  • Manufacturer product family
  • Manufacturer product designation
  • name of supplier
  • Supplier product order suffix
  • Manufacturer name
  • Manufacturer product description
  • URI of the product
  • outlet pressure
  • assembly torque
  • working time (mileage)
  • burst pressure
  • through drive torque
  • inlet pressure
  • inlet flow rate
  • remaining working time (time)
  • mechanical power
  • cracking pressure
  • remaining working time (mileage)
  • remaining working time (cycles)
  • working time (time)
  • working time (cycles)
  • torque ripple
  • differential pressure
  • total flow rate
  • hydraulic power
  • starting torque
  • drive torque
  • flow ripple
  • flow rate a-b
  • flow rate amplification
  • storage temperature
  • fluid temperature
  • end value of the measuring range (flow rate)
  • initial value of the measuring range (pressure)
  • end value of the measuring range (pressure)
  • output torque
  • electrical power consumption
  • set pressure
  • storage time
  • product article number of supplier
  • GLN of supplier
  • Supplier product designation
  • Supplier product description
  • Supplier product family
  • Supplier product type
  • Supplier product root
  • switching pressure difference
  • remaining operating time (time)
  • control flow rate
  • closing pressure
  • supply flow rate
  • product life (time)
  • overload pressure
  • initial value of the measuring range (flow rate)
  • ambient temperature
  • flow rate
  • operating time
X