Classification: 51510101 [AGW313004]

Preferred name 51-51-01-01 Bladder accumulator standard (hydraulics)
Definition Gas-loaded accumulator in which separation between the liquid and gas sides is achieved by a flexible bladder
IRDI 0173-1#01-AGW313#004
Already on the watchlist: 0 of max. 4

BASIC Properties: Bladder accumulator standard (hydraulics)

  • remaining working time (time)
  • flow ripple
  • hydraulic power
  • inlet flow rate
  • remaining operating time (time)
  • operating time
  • working time (cycles)
  • working time (time)
  • flow rate
  • storage time
  • burst pressure
  • working time (mileage)
  • fluid temperature
  • overload pressure
  • product life (time)
  • mechanical power
  • storage temperature
  • remaining working time (cycles)
  • remaining working time (mileage)
  • ambient temperature
  • pneumatic power
  • GTIN
  • URI of the product
  • Manufacturer product family
  • product article number of manufacturer
  • Supplier product order suffix
  • name of supplier
  • Supplier product type
  • Manufacturer product description
  • Manufacturer name
  • URI of manufacturer
  • Supplier product designation
  • GLN of supplier
  • product article number of supplier
  • Supplier product root
  • Supplier product family
  • Supplier product description
  • address of additional link
  • Customs tariff number
  • Valuelist Type of customs tariff number
  • Valuelist Use of customs tariff number
  • HS-Code of the WCO
  • Product type
  • Brand
  • Manufacturer product designation
  • GLN of manufacturer
  • Manufacturer product order suffix
  • Manufacturer product root
  • actual product life (time)
  • specified maximum product life (time)
  • last flow rate
  • actual flow rate
  • maximum set of remaining working time (time)
  • specified minimum remaining working time (cycles)
  • specified maximum remaining working time (cycles)
  • specified minimum flow rate
  • specified maximum flow rate
  • minimum set flow rate
  • actual average flow rate
  • actual maximum flow rate
  • actual minimum flow rate
  • nominal flow rate
  • maximum set working time (time)
  • actual average flow ripple
  • last working time (time)
  • actual maximum flow ripple
  • minimum set working time (cycles)
  • specified maximum working time (time)
  • actual flow ripple
  • minimum set working time (mileage)
  • actual operating time
  • set flow ripple
  • maximum set flow ripple
  • minimum set flow ripple
  • actual working time (time)
  • actual minimum flow ripple
  • maximum set operating time
  • last operating time
  • actual storage time
  • specified minimum operating time
  • specified maximum operating time
  • minimum set operating time
  • minimum set working time (time)
  • last flow ripple
  • maximum set of remaining working time (mileage)
  • specified maximum storage time
  • specified maximum remaining operating time (time)
  • maximum set of remaining operating time (time)
  • specified minimum remaining working time (time)
  • specified maximum remaining working time (time)
  • specified minimum remaining working time (mileage)
  • specified maximum remaining working time (mileage)
  • maximum set of remaining working time (cycles)
  • specified minimum remaining operating time (time)
  • last pneumatic power
  • actual pneumatic power
  • specified minimum pneumatic power
  • specified maximum pneumatic power
  • nominal mechanical power
  • nominal pneumatic power
  • actual minimum pneumatic power
  • actual maximum pneumatic power
  • actual working time (mileage)
  • last fluid temperature
  • actual fluid temperature
  • specified maximum fluid temperature
  • minimum set pneumatic power
  • maximum set pneumatic power
  • set pneumatic power
  • last working time (mileage)
  • specified minimum working time (mileage)
  • specified maximum working time (mileage)
  • minimum set fluid temperature
  • maximum set working time (mileage)
  • specified minimum fluid temperature
  • maximum set working time (cycles)
  • last working time (cycles)
  • actual working time (cycles)
  • specified maximum working time (cycles)
  • specified maximum flow ripple
  • specified minimum flow ripple
  • specified minimum working time (time)
  • set fluid temperature
  • actual maximum fluid temperature
  • actual minimum fluid temperature
  • specified minimum working time (cycles)
  • maximum set fluid temperature
  • specified maximum inlet flow rate
  • maximum set hydraulic power
  • specified minimum inlet flow rate
  • actual maximum inlet flow rate
  • specified maximum hydraulic power
  • actual minimum inlet flow rate
  • minimum set hydraulic power
  • actual maximum ambient temperature
  • actual minimum ambient temperature
  • last ambient temperature
  • actual ambient temperature
  • set hydraulic power
  • nominal hydraulic power
  • actual minimum hydraulic power
  • set ambient temperature
  • actual maximum mechanical power
  • last inlet flow rate
  • last mechanical power
  • actual mechanical power
  • specified maximum ambient temperature
  • maximum set inlet flow rate
  • actual minimum mechanical power
  • minimum set inlet flow rate
  • minimum set ambient temperature
  • maximum set mechanical power
  • set mechanical power
  • set inlet flow rate
  • specified minimum mechanical power
  • specified maximum mechanical power
  • maximum set ambient temperature
  • minimum set mechanical power
  • min. storage temperature
  • max. storage temperature
  • set flow rate
  • actual maximum hydraulic power
  • certification
  • actual inlet flow rate
  • specified minimum ambient temperature
  • actual average inlet flow rate
  • specified minimum hydraulic power
  • maximum set flow rate
  • last hydraulic power
  • actual hydraulic power
  • load collective